JUMO screw-in resistance thermometer with connection head form J, with stepped protection tube for air measurement (with 1 x Pt to Ø 2.6 mm, with 2 x Pt to Ø 3.5 mm)

Product number: 802031
Product information "JUMO screw-in resistance thermometer with connection head form J, with stepped protection tube for air measurement (with 1 x Pt to Ø 2.6 mm, with 2 x Pt to Ø 3.5 mm)"

Screw-in resistance thermometer with connection head form J

Type: 902030/31-380-1003-1-6-150-104/000

  • with stepped protection tube for air measurement
  • Measuring range from -50 to +200 °C
  • Single resistance thermometer
  • 1x Pt 100 in two-wire circuit
  • Tolerance class: Class B (standard)
  • Thermowell diameter: 6 mm
  • Installation length: 150 mm
  • Process connection: G1/2 threaded connection
  • Extra codes: none

The screw-in RTD temperature probe with connection head is specially designed for use in various industries such as air conditioning and refrigeration technology and heating, furnace and apparatus engineering. It offers precise temperature measurement in both liquid and gaseous media, with a temperature range of -50 to +400 °C.

The installation design of this thermometer ensures reliable tightness, even under extreme conditions of negative and positive pressure.

The measuring insert is fitted as standard with a Pt100 temperature sensor in accordance with the DIN EN 60751:2009 / IEC 60751:2008 standards. This sensor has a temperature coefficient α of 3.850 × 10-3 °C-1 and is installed in a two-wire circuit. Versions with Pt500 or Pt1000 are also available as an option. For more precise measurement results, the connection can be made either in a three-wire or four-wire circuit, and it is also possible to integrate a transmitter into the connection head.

Other attributes

Customs tariff number 90251900
Einbaulänge in mm 150 mm
Messeinsatz 1x Pt 100 Zweileiterschaltung
Prozessanschluss Verschraubung G 1/2
Temperaturbereich -50°C ... +200°C
Technical Data:

Connection head:

Process connection:, ambient temperature -40 to +100 °C Attention: reduced ambient temperature when using transmitters, data sheet 707030

 

If the design permits, yellow connection heads are used for SIL and PL applications (extra codes 658 and 659). Exceptions are sensors for use in alkaline environments and sensors for which LABS freedom is mandatory.

Process connection:

Thread, stainless steel 1.4571

Thermowell:

Stainless steel 1.4571, Ø 6 mm and Ø 8 mm

Measuring insert:

Pt100 temperature sensor, DIN EN 60751:2009 / IEC 60751:2008, class B, two-wire circuit

Response times:

t0.5 = 8 s, t0.9 = 20 s, in water 0.4 m/s, Ø 8 mm

 

t0.5 = 5 s, t0.9 = 12 s, in water 0.4 m/s, Ø 6 mm

 

t0.5 = 40 s, t0.9 = 110 s, in air 3.0 m/s, Ø 6 mm

 

t0.5 = 2 s, t0.9 = 5 s, in water 0.4 m/s, Ø 6 mm reduced to Ø 3.5 mm

 

t0.5 = 25 s, t0.9 = 85 s, in air 3.0 m/s, Ø 6 mm stepped down to Ø 3.5 mm

 

t0.5 = 1 s, t0.9 = 2 s, in water 0.4 m/s, Ø 6 mm reduced to Ø 2.6 mm

 

t0.5 = 18 s, t0.9 = 65 s, in air 3.0 m/s, Ø 6 mm stepped down to Ø 2.6 mm

Measuring transducer:

analogue transmitter, output 4 to 20 mA

Accessories:

Protective sleeve, data sheet 909710