Content: 2 x 40170 sight glass 30x33 x 33777 flat gasket 24x2 EPDM 602 x 33776 O-Ring 18x2 EPDM3 x 11210 Protection plug to measuring chamber T2000 / ECO / EVO TH / EVO TH CAL1 x 40050 Magnetic stirring core
Service Set Professional for 2-Year Maintenance of Testomat® 808 The Service Set Professional ensures maintenance of your Testomat® 808 for 2 years. All relevant wear and replacement parts are included in this set. Complete Maintenance Set for Testomat® 808 The Service Set Professional ensures that your Testomat® 808 operates reliably and accurately over a period of two years. The set includes all relevant wear and replacement parts needed for regular maintenance, enabling professional and scheduled care of the device. Scope and Benefits of the 2-Year Maintenance Package The maintenance set is specifically tailored to the requirements of the Testomat® 808 and includes both mechanical and functional replacement parts. Timely replacement of sight glasses, gaskets, pump and drive components increases measurement reliability and reduces unplanned downtime. Additional cleaning tools support proper care of the device throughout the maintenance period. Comprehensive Maintenance Package for Professional Care Over Two Years for the Testomat® 808 by Heyl This set consists of: 2 x Sight glasses 30 x 3 3 x Flat gasket 24 x 2 1 x Insert for screw cap and suction tube 500 ml bottle 1 x Pump head Testomat® 808 1 x Gear motor 2 x Hose adapters 1 x Cleaning brush set
Service set contains:2 x sight glasses 30 x 33 x flat gasket 24 x 21 x insert for screw cap & suction tube 100 ml bottle1 x insert for screw cap & suction tube 500 ml bottle1 x double pump head conversion kit1 x gear motor2 x Hose connector1 x Cleaning brush set Important: After replacement, the pump must be recalibrated in Testomat® 808 SiO2.The adjustment is available from firmware version T808_83-003. Carry out a firmware update for older versions before performing the adjustment! (Serial number less than 253.061)For this calibration, it is important that you use water with a silicate content of 0 ppm, otherwise the zero point calibration will be incorrect and lead to false measurement results.To ensure this, please use the silicate filter cartridge specially developed for this process for the T808 SiO2, article 270344.(For additional information and instructions on the equipment you need for the software update, please refer to the operating instructions. The instructions "Replacing the pump head on Testomat® 808 SiO2" are also available)
This special service set is designed for the Testomat 2000® PO4. Included are the standard spare parts for the Testomat 2000® together with spare parts for the PeriClip® pump, i.e. the pump head. The service set includes the following spare parts: 1 T2000 gasket kit 2 30x3 sight glass 1 flow regulator cores 3 stoppers for m. chamber 2 x pump head 1 filter screen for intake 3 different pipes 1 cleaning brush set 2 x tube connection 2 x seal for tube connection 1 x screw cap with insert for 500 ml bottle 1 x screw cap with insert for 100 ml bottle
This special service set is designed for the Testomat 2000® Polymer. Included are the standard spare parts for the Testomat 2000® together with spare parts for the PeriClip® pump, i.e. the pump head. The service set includes the following spare parts: 1 T2000 gasket kit 2 30x3 sight glass 1 flow regulator cores 3 stoppers for m. chamber 2 x pump head 1 filter screen for intake 3 different pipes 1 cleaning brush set 2 x tube connection 2 x seal for tube connection 2 x screw cap with insert
Service Set for Testomat® 808 – Maintenance Spare Parts Complete Maintenance Kit for Regular Care The service set for the Testomat® 808 contains all the essential spare parts for maintaining your device. This set includes: 15 x Flat gasket 24 x 2 6 x Sight glass 30 x 3 6 x O-ring 3.68 x 1.78 6 x O-ring 4.5 x 1.5 6 x O-ring 1.78 x 1.78 1 x Pipe, PE, D=6 d=4 L=53mm 1 x Pipe, PE, D=6 d=4 L=140mm 1 x Cleaning brush set Complete Maintenance Kit for Regular Care of the Testomat® 808 Hardness The service set for the Testomat® 808 contains all essential spare and wear parts required for regular maintenance and care of the device. By regularly replacing gaskets, sight glasses, and pipes, measurement deviations and malfunctions can be prevented early. This kit is ideal for operators and service teams who want to ensure the long-term operational reliability, measurement accuracy, and lifespan of their Testomat® 808. Advantages of the Service Set for Testomat® 808 The service set enables fast and structured maintenance, as all necessary spare parts are available in one package. Wear parts such as O-rings, flat gaskets, and sight glasses can be replaced without additional spare part procurement, reducing downtime. Additionally, the included cleaning brush set ensures thorough care of the measurement chamber and contributes to consistently high measurement quality of the Testomat® 808. The service set supports cost-effective and preventive maintenance.
Annual Service Set for Testomat® EVO TH, 2000 & ECO / Titromat® Annual Recommended Maintenance Package for High Operational Reliability The annual service set for Testomat 2000®, Testomat ECO®, Titromat®, and Testomat® EVO TH includes all essential wear parts required for yearly maintenance. The set includes: 1 x Seal Kit T2000 2 x Sight Glass 30x3 3 x Disc Plugs 5.3dx5 PE natural 1 x Valve Set for Injection Pump 1 x Inlet Filter 19.5dx25 Recommended Maintenance Package for Annual Service of Your Water Analysis Devices The annual service set for Testomat® EVO TH, Testomat® 2000, Testomat® ECO, and Titromat® contains all essential wear parts that should be replaced as part of the yearly recommended maintenance. It ensures reliable operation and helps maintain measurement accuracy at a consistently high level. Regular replacement of the included components prevents unplanned downtime, allows efficient planning of maintenance intervals, and sustainably increases the operational reliability of the devices. Advantages of the Annual Service Set for Testomat® & Titromat® Devices The annual service set offers a practical, all-in-one solution with all relevant spare parts for yearly maintenance. Wear parts such as seals, sight glasses, disc plugs, and valve components can be replaced quickly without the need for additional spare parts. This reduces downtime, simplifies on-site maintenance processes, and ensures consistently high measurement quality in industrial and commercial water treatment. At the same time, the set supports economical and preventive maintenance of Heyl Testomat® and Titromat® devices.
Service Set for Testomat® EVO TH, Testomat® 2000®, Testomat® ECO® & Titromat® Complete Service Set for Regular Professional Maintenance of Your Water Analysis Devices The service set contains all essential spare parts and wear components required for the regular maintenance of your Testomat 2000®, Testomat ECO®, Titromat®, or Testomat® EVO TH devices. The service set includes: 1 x T2000 Seal Kit 2 x Sight Glasses 30x3 1 x Complete Flow Regulator Core 3 x Plugs for Measuring Chamber 1 x Valve Set for Injection Pump 1 x Inlet Filter Screen 19.5dx25 3 x Various Pipes 1 x Cleaning Brush Set Why is Regular Maintenance of Water Analysis Devices Important? Regular maintenance is essential for measurement accuracy, operational reliability, and the lifespan of water analysis devices. Wear parts such as seals, sight glasses, or valves naturally degrade over time due to water, chemicals, and mechanical stress. With a professional service set, you ensure that your Testomat® EVO TH, Testomat® 2000®, Testomat® ECO®, or Titromat® consistently delivers reliable measurement results, prevents unplanned downtime, and allows maintenance intervals to be followed efficiently. Advantages of the Service Set for Testomat® & Titromat® Devices The service set contains all essential spare and wear parts required for comprehensive maintenance. Replacing components on a planned maintenance cycle helps prevent measurement deviations early and maintains the functional reliability of the analysis devices. Additionally, the set reduces organizational effort because all relevant parts are included in a single package. This saves time on procurement, minimizes downtime, and supports economical and safe operation in industrial and commercial water treatment systems.
Service Set for Testomat® LAB CL and Monochloramine – Maintenance Spare Parts Complete Set of Spare Parts for Your Water Analysis Device The service set for the Testomat® LAB CL and Monochloramine provides all essential spare parts for regular maintenance. It has been specially designed for the Testomat® LAB CL and Monochloramine devices. The set includes: 1 x Seal Kit T2000 2 x Sight Glass 30x3 1 x Flow Regulator Core 3 x Plugs for Measuring Chamber 2 x Screw Cap with T2000 Insert 1 x Inlet Filter 19.5dx25 5 x Various Pipes 1 x Cleaning Brush Set 1 x Pump Head 2 x Hose Connectors 2 x Hose Adapter Seals Complete Spare Parts Set for Regular Maintenance of Testomat® LAB CL Devices The service set for the Testomat® LAB CL and Monochloramine contains all essential spare and wear parts needed for regular maintenance and care of the Heyl water analysis device. It is specifically designed to meet the technical requirements of these devices and ensures reliable, trouble-free measurement of chlorine and monochloramine levels with the Testomat LAB CL devices. By regularly replacing the included components, measurement deviations, malfunctions, and unplanned downtime can be effectively avoided. Advantages of the Service Set for Testomat® LAB CL & Monochloramine The service set offers a practical all-in-one solution, with all required spare parts clearly organized in one package. Wear parts such as seals, sight glasses, pump head, and hose connectors can be replaced quickly without the need for additional spare parts. This reduces maintenance time, simplifies service tasks, and ensures consistently high measurement accuracy as well as long service life of the Testomat® LAB CL and Monochloramine devices. The included cleaning brush set also supports thorough maintenance of the measuring chamber, contributing to stable and reliable measurement operations.
There is a separate service set especially for Testomat® LAB TH, which contains important spare parts. The service set includes the following spare parts: 1 T2000 gasket kit 2 sight glasses 30x3 1 flow regulator core 3 measuring chamber plugs 1 filter screen for intake 5 different pipes 1 cleaning brush set 2 x screw cap with insert for 500 ml bottle
Content: 1 x 40121 inlet connector1 x 40122 outlet connector,PVC1 x 11225 Flow regulator core (1-8 bar)2 x 11216 O-Ring 20x2 (NBR) 1 x 11217 filter strainer for feed 19,5dx251 x 33777 flat gasket 24x2 EPDM 601 x 40153 screw connector G1/4"-61 x 40129 controller plug T2000,cpl.
Content: 1 x #40011 suction hose, cpl.1 x #40016 pressure hose, cpl.1 x #40040 valve set for jet pump
Spare part: Set of valves for Pump DOSIClip®
The sight glass set contains two sight glasses made of Plexiglas and the corresponding seals. Can be used for the Testomat ECO®/ 2000.
Spare part: Sight glass windows 30×3 for measuring chamber of Testomat ECO®, Testomat 2000®, Testomat® 808.
Dear customers, please note that the calibration of the Testomat® 808 SiO2 can only be carried out with silicate-free water. Therefore, please use the silicate filter cartridge specially developed for this purpose when replacing the double pump head (art. no. 40395) and the associated pump adjustment.The cartridge filled with the special resin is inserted into the sampling line of the unit before the inlet and removed again after the adjustment. The pump replacement instructions describe the use of the silicate filter, storage conditions and shelf life. After the first use, the filter can be used up to 10 times within one year for balancing. After one year, the filter must be disposed of.
The sleeve is a spare part for the Testomat LIMIT
Solenoid valve 2-2 way, 24 V, spare part for the Testomat LIMIT
Solenoid valve, 2/2-way for chamber holder of TESTOMAT®2000
Spacer ring for Discharge funnel 40x30x3, spare part for the Testomat LIMIT
Plug-in card for a voltage interface, suitable for Testomat 2000® and Titromat® instruments. Technical Data output voltage: 0/2-10V galvanic isolation:
Content of Standard Analysis Cabinet Type H: Titration kits: Duroval® A, Duroval® B, Duroval® CPM Colour comparison kits Testoval®: Sulfit, Phosphate test®, pH value 8-12 1 aerometer 1 graduated cylinder 100 ml 1 beaker 500 ml 1 beaker 100 ml 1 funnel 50 folding filters