The pressure regulator is suitable for all Testomat® devices. It is used for pressures from 0.5 to 10 bar in order to avoid any pressure fluctuations that may occur and to ensure an optimum operating pressure. Kit consisting of: Pressure gauge, rear connection Bracket with nut 2 x straight screw-in fittings 1/4 ‘ x 6 mm Technical data: max. inlet pressure: 25 bar Ambient temperature: 0-50 °C Pressure gauge connection G 1/4 Weight: 200 g City water: approved Soft water: approved Demineralised water: not approved Condensate: not authorised
Pressure regulator, complete for Testomat® 808Testomat® 808 / Testomat 2000® / Testomat ECO® The pressure regulator is used for pressures over 4 bar. - max. inlet pressure: 11 bar/159.5 psi - ambient temp.: 0-50 °C/32-122 °F - manometer connection: G1/8 - on both sides - non-reversible
Dear customers, please note that the calibration of the Testomat® 808 SiO2 can only be carried out with silicate-free water. Therefore, please use the silicate filter cartridge specially developed for this purpose when replacing the double pump head (art. no. 40395) and the associated pump adjustment.The cartridge filled with the special resin is inserted into the sampling line of the unit before the inlet and removed again after the adjustment. The pump replacement instructions describe the use of the silicate filter, storage conditions and shelf life. After the first use, the filter can be used up to 10 times within one year for balancing. After one year, the filter must be disposed of.
Plug-in card for a voltage interface, suitable for Testomat 2000® and Titromat® instruments. Technical Data output voltage: 0/2-10V galvanic isolation:
9 pole, 2 x bush, 3m • associated USB adapter #850929
for bulk container reagent A PO4 (20 liter container)
for large containers of reagent B PO4 (5 liter containers)
Testomat® aerator for reducing the CO2 content. Capacity: Max. water throughput of 12 l/h when reducing the free carbon dioxide from max. 200 mg/l to below 20 mg/l. A high carbon dioxide content in the sample water distorts the measurement results. Therefore, insert the small aerator R upstream of the Testomat® device to reduce the CO2 content in the sample water. Dimensions (W x H x D): 150 x 500 x 100 mm Supply voltage: 230 V/50 Hz. Attention: The mounting of the Aerator R has to be 3 meters over the device!
256x64 2,8", yellowFeatures: When the device is switched on with the display plugged in, the installed software version is displayed during the boot process. This allows you to visually check the current software version after a software update. After a measurement has been completed, the measurement result is shown in the selected display unit. The display value is retained until the end of the next measurement and is then updated to the new measured value. If a fault occurs during the last measurement, the display shows “xx x x x selected display unit”. If it is a temporary fault, the Alarm function key flashes at the same time (see Temporary faults in the manual). In this case, the device will start a new measurement once the programmed analysis interval has expired. If the error is still present, the indication on the display remains and the Alarm function key remains illuminated. In this case, no further measurements are made during programmed analysis interval and the device switches to standby mode. If the fault is no longer present, the measurement result is shown on the display once the measurement has been completed and the device switches back to normal operating mode.
Contents: 1 x Screwdriver Torx 10x80-3K1 x screwdriver VDE slot 0,5x3x1001 x water pump pliers, infinitely variable1 x flat round nose pliers VDE L200MM1 x screwdriver Torx 8x60-3K1 x screwdriver Torx 9x60-3K1 x screwdriver VDE slot 0,5x3x100
Contents: 1 x Screwdriver VDE Slot 0,5x3x100 1 x Screwdriver VDE-PH-SLIM 1X80 1 x Screwdriver VDE-PH 0x60 1 x Screwdriver Torx 9x60-3K 1 x Screwdriver VDE Slot 0,4x2,5x80
1 x screwdriver Torx TX20 20x100 1 x screwdriver Torx TX10 10x80 1 x screwdriver Torx8 8x60
The data logger with USB connection can be used in Testomat® 808 devices. It provides a protocol of the readings and notifications of the Testomat® 808 using the 20mA current loop. Data access is performed via the built-in USB port. Technical Data Monitors the Testomat® 808 continuously. Storage capacity for 32000 samples. Assuming a typical interval pause time of 15 minutes, 10 months data can be captured. Battery lifetime more than 1 year Data access via USB port Drivers and application usable with Windows XP, Windows Vista, Windows 7 and Windows 8 (32 und 64 bit) operating systems Readings are shown in web browser in HTML format in table format with timestamp. Printable directly from browser. In addition readings are stored in CSV format for convenient post processing with office software