N-LF1201 conductivity measuring cell C=0.1 with PT100, 1/2 inch screw-in cell and solenoid valve connector

Product number: 880576

€134.47*

Please log in to receive your conditions.

Available, delivery time: 1-2 days

screw-in cel
measuring range

Product number: 880576
GTIN: 4260682383679
Measuring range: 0-10 / 0-100 / 0-20 / 0-200 µS/cm
Application: for N-LF10 / N-LF100 or N-LF2000
Offer as PDF  
Login for addressed offer
The entered number of pieces will be taken into account when creating the offer.
Product information "N-LF1201 conductivity measuring cell C=0.1 with PT100, 1/2 inch screw-in cell and solenoid valve connector"
Technical data:
Screw-in thread: 1/2 "
Material housing: POM black
Material electrodes: V4A 4571
Material O-ring: EPDM
Cell constant: C=0.1 +/- 10%.
Max. Operating pressure: 6 bar
Max. Operating temperature: 60°C
Temperature sensor: PT100
Solenoid valve connector: ST2+SL electrodes
Colour cable green/yellow
St1+St2 PT 100
Colour cable brown/white

Dimensions

Height 5,5 cm
Width 8 cm, 16 cm

Weight

Weight 116 g

Other attributes

Country of origin DE
Customs tariff number 90278930

We recommend that you perform a calibration after installation and use our conductivity meter N-LF2000:

3 meter connection cable for N-LF measuring cells, 4-core 0.25² with shielding
Product number: 880652
Cable length: 3 meters
- 1 side connected to solenoid valve connector without seal ("Plug and Play", as plug only has to be plugged onto measuring cell)- 1 side labelled cable with wire end ferruleswhite: PT100brown: PT100yellow: Measuring cell SL green: Measuring cellblue: shielding

€46.71*
Conductivity calibration solution
Product number: 890696
Kalibierlösung: 147 μS/cm (±1% @25°C) | Size of bottle: 250 ml
High quality conductivity calibration solution to calibrate your electrodes Our 250 ml, 500 ml and 1000 ml bottle is characterized by a special hygienic closure, which protects the conductivity calibration solution from contamination. To provide the required calibration solution, simply squeeze the bottle together and enough conductivity calibration solution is delivered to the upper part of the bottle to perform a calibration.

€11.06*
Conductivity calibration solution
Product number: 890697
Kalibierlösung: 1413 μS/cm (±1% @25°C) | Size of bottle: 250 ml
High quality conductivity calibration solution to calibrate your electrodes Our 250 ml, 500 ml and 1000 ml bottle is characterized by a special hygienic closure, which protects the conductivity calibration solution from contamination. To provide the required calibration solution, simply squeeze the bottle together and enough conductivity calibration solution is delivered to the upper part of the bottle to perform a calibration.

€11.06*
Tip
N-LF2000, conductivity measuring instrument 0-20/200/2000μS/cm in wall mounted housing
Product number: 880571
Instrument for measuring the electrical conductivity of aqueous solutions in conjunction with two-electrode measuring cells. Designed as wall-mounted version.Operation at 230 V AC or 24 V DC possible2 potential-free relays - changeover switch for limit value switching (hysteresis 5 % fixed)Alphanumeric display with 2 x 16 charactersTemperature measurement and temperature display from 0.0 °C to 90.0 °C when a Pt100 is connectedSwitchable temperature compensation with 2.2 % / K up to 90 °CMonitoring of the temperature sensor for sensor break and error message on the displaySwitchable mode of operation for relay controlOutput of the measured value with 0 - 10 V and 4 - 20 mA Technical data Measuring ranges: dependent on measuring cell and amplification Temperature compensation: Linear 2.2 % / K, can be switched off, reference temperature 25 °CLimit value displays: Optical by means of 2 LEDs, 2 limit values adjustable over the measuring range Limit value outputs: 1 potential-free changeover contact, max. 6 A / 250 V AC1 change-over contact to 230V AC (terminal 21) Analog outputs: 0 - 10 V, Ra > 1 kOhm; corresponds to 0 - 20 / 200 / 2000 μS/cm 4 - 20 mA, Ra < 500 Ohm; corresponds to 0 - 20 / 200 / 2000 μS / cm Power supply: 22 - 26 V DC, protected against reverse polarity, electrically isolated, 1000 V insulation voltage, or 230 V 50/60 Hz Power consumption: Approx. 3 W / 3 VA Protection class: IP 65 Housing: Surface-mounted housing (polycarbonate) 120 x 122 x 57 mm Connections: 4 x M16 cable entries on the bottom of the housing.

€584.65*
6 meter connection cable for N-LF measuring cells, 4-core 0.25² with shielding
Product number: 880653
Cable length: 6 meters
- 1 side connected to solenoid valve connector without seal ("Plug and Play", as plug only has to be plugged onto measuring cell)- 1 side labelled cable with wire end ferruleswhite: PT100brown: PT100yellow: Measuring cell SL green: Measuring cellblue: shielding

€59.98*
Conductivity calibration solution
Product number: 890695
Kalibierlösung: 84 μS/cm (±1% @25°C) | Size of bottle: 250 ml
High quality conductivity calibration solution to calibrate your electrodes Our 250 ml, 500 ml and 1000 ml bottle is characterized by a special hygienic closure, which protects the conductivity calibration solution from contamination. To provide the required calibration solution, simply squeeze the bottle together and enough conductivity calibration solution is delivered to the upper part of the bottle to perform a calibration.

€11.06*