Skip to main content Skip to search Skip to main navigation

N-LF1210/PT1000, conductivity measuring cell K=1.0 with PT1000, screw-in thread 1/2'', solenoid valve plug

Product number: 882010
Our service hotline – We are here for you 📞 +49 (0) 5121 7609 99

Product information "N-LF1210/PT1000, conductivity measuring cell K=1.0 with PT1000, screw-in thread 1/2'', solenoid valve plug "

Conductivity measuring cell N-LF1210/PT1000 – Buy online

Precise measurement for your water analysis

The conductivity measuring cell N-LF1210/PT1000 is the ideal solution for precise conductivity measurements in water treatment and process applications. With a cell constant K=1.0 and integrated PT1000 temperature sensor, it offers maximum accuracy and reliability. Thanks to the 1/2'' screw-in thread and solenoid valve plug, installation is particularly easy and safe.

Your advantages at a glance

Wide measuring range: 0–2000 µS/cm for N-LF2000 and 0–1000 µS/cm for N-LF1000

Robust materials: Black POM housing, V4A 4571 electrodes, EPDM O-ring

High load capacity: max. operating pressure 6 bar, temperature up to 60 °C

Easy integration: compatible with common conductivity meters

Areas of application:

The N-LF1210/PT1000 is perfect for:

Water treatment and drinking water monitoring

Process control in industrial plants

Laboratory applications and quality assurance

Why buy online?

Benefit from fast delivery, attractive prices and expert support. Order the N-LF1210/PT1000 conductivity measuring cell now and ensure precise measurements for your applications.

Dimensions

Height 5 cm
Length 12 cm
Width 8 cm

Weight

Weight 100 g

Other attributes

Country of origin DE
Customs tariff number 90278930
Skip product gallery

We recommend the following

Neomeris conductivity calibration solution
Product number: 890695
Kalibierlösung: 84 μS/cm (±1% @25°C) | Size of bottle: 250 ml
Neomeris Conductivity & TDS Calibration Solution 84 μS/cm ± 1% (25 °C), 250 ml – Precise calibration for reliable EC and TDS measurements The Neomeris Conductivity & TDS Calibration Solution with a defined value of 84 μS/cm ± 1% at 25 °C is specially designed for calibrating electrical conductivity (EC) and total dissolved solids (TDS) measuring instruments. It ensures precise and reproducible measurement results in a wide range of applications – from water analysis to industrial process monitoring. Product advantages at a glance: ✔️ Precise calibration: Stable reference value with an accuracy of ± 1 % at 25 °C – ideal for precise requirements. ✔️ Certificate of analysis included: Each bottle comes with a free certificate confirming the quality and accuracy of the solution. ✔️ Safe handling: The special hygienic cap reliably protects the solution from contamination. ✔️ Easy dosing: Squeezing the bottle releases the required amount of solution into the upper part – ideal for direct calibration without additional accessories. ✔️ 250 ml content: Practical for regular use in laboratories, businesses and educational institutions. Areas of application: Water and environmental analysis: Assessment of water quality by monitoring mineral and ion concentrations. Food and beverage industry: Ensuring product consistency and hygiene through precise conductivity measurements. Agriculture & hydroponics: Monitoring nutrient availability in soils and nutrient solutions. Industrial processes: Monitoring in electroplating, chemical production and energy generation. Research and teaching: Reference solution for precise experiments and training. Neomeris – For reliable EC and TDS measurements. Rely on quality, safety and verifiability – with professional calibration solutions from Neomeris, including a certificate of analysis.

€11.06*
Neomeris conductivity calibration solution
Product number: 890696
Kalibierlösung: 147 μS/cm (±1% @25°C) | Size of bottle: 250 ml
Neomeris Conductivity & TDS Calibration Solution 147 μS/cm ± 1% (25 °C), 250 ml – Precise calibration for reliable EC and TDS measurements The Neomeris Conductivity & TDS Calibration Solution, with a stable reference value of 147 μS/cm ± 1% at 25 °C, is specially designed for calibrating measuring instruments used to determine electrical conductivity (EC) and total dissolved solids (TDS). It ensures precise and reproducible measurement results in numerous areas of application – from environmental analysis to industrial process control. Product advantages at a glance: ✔️ Precise calibration: Constant conductivity value with an accuracy of ± 1 % at 25 °C – ideal for precise requirements. ✔️ Certificate of analysis included: Each 250 ml bottle comes with a free certificate confirming the quality and accuracy of the solution. ✔️ Safe handling: The innovative hygienic cap reliably protects the solution from contamination. ✔️ Easy dosing: Squeezing the bottle releases the required amount of solution into the upper part – ideal for direct calibration without additional accessories. ✔️ 250 ml content: Practical for regular use in laboratories, businesses and educational institutions. Areas of application: Water and environmental analysis: Assessment of water quality by monitoring mineral and ion concentrations. Food and beverage industry: Ensuring product consistency and hygiene through precise conductivity measurements. Agriculture & hydroponics: Monitoring nutrient availability in soils and nutrient solutions. Industrial processes: Monitoring in electroplating, chemical production and energy generation. Research and teaching: Reference solution for precise experiments and training. Neomeris – For reliable EC and TDS measurements. Rely on quality, safety and verifiability – with professional calibration solutions from Neomeris, including a certificate of analysis.

€11.06*
Neomeris conductivity calibration solution
Product number: 890697
Kalibierlösung: 1413 μS/cm (±1% @25°C) | Size of bottle: 250 ml
Neomeris Conductivity Calibration Solution – Accurate EC and TDS Reference Standard Solutions Standard solutions for calibrating and verifying conductivity meters The Neomeris Conductivity and TDS Calibration Solution is a standardized reference solution for precise calibration and verification of instruments measuring electrical conductivity (EC) and Total Dissolved Solids (TDS). With a stable reference value of 1413 µS/cm ± 1% at 25 °C, it ensures reliable and reproducible results across a wide range of applications. Precise Reference Solution for Conductivity Meter Calibration The special hygiene cap reliably protects the calibration solution from contamination and ensures safe handling. Each 250 ml bottle comes with a certificate confirming the quality and accuracy of the reference solution. The solution is suitable for numerous applications, including water and environmental analysis, food and beverage industry, agriculture and hydroponics, industrial processes, as well as research and teaching. Reliable Use and Versatile Applications In which application areas can the solution be used? Water and Environmental Analysis: Monitoring mineral and ion concentrations to assess water quality. Food and Beverage Industry: Ensuring product consistency and hygiene through precise conductivity measurements. Agriculture & Hydroponics: Monitoring nutrient availability in soils and nutrient solutions. Industrial Processes: Process control in electroplating, chemical production, and energy generation. Research & Education: Reference solution for precise experiments and training.

€11.06*
6 meter connection cable for N-LF measuring cells, 4-core 0.25² with shielding
Product number: 880653
Cable length: 6 meters
- 1 side connected to solenoid valve connector without seal ("Plug and Play", as plug only has to be plugged onto measuring cell)- 1 side labelled cable with wire end ferruleswhite: PT100brown: PT100yellow: Measuring cell SL green: Measuring cellblue: shielding

€59.98*
Tip
N-LF2000, conductivity measuring instrument 0-20/200/2000μS/cm in wall mounted housing
Product number: 880571
Instrument for measuring the electrical conductivity of aqueous solutions in conjunction with two-electrode measuring cells. Designed as wall-mounted version.Operation at 230 V AC or 24 V DC possible2 potential-free relays - changeover switch for limit value switching (hysteresis 5 % fixed)Alphanumeric display with 2 x 16 charactersTemperature measurement and temperature display from 0.0 °C to 90.0 °C when a Pt100 is connectedSwitchable temperature compensation with 2.2 % / K up to 90 °CMonitoring of the temperature sensor for sensor break and error message on the displaySwitchable mode of operation for relay controlOutput of the measured value with 0 - 10 V and 4 - 20 mA Technical data Measuring ranges: dependent on measuring cell and amplification Temperature compensation: Linear 2.2 % / K, can be switched off, reference temperature 25 °CLimit value displays: Optical by means of 2 LEDs, 2 limit values adjustable over the measuring range Limit value outputs: 1 potential-free changeover contact, max. 6 A / 250 V AC1 change-over contact to 230V AC (terminal 21) Analog outputs: 0 - 10 V, Ra > 1 kOhm; corresponds to 0 - 20 / 200 / 2000 μS/cm 4 - 20 mA, Ra < 500 Ohm; corresponds to 0 - 20 / 200 / 2000 μS / cm Power supply: 22 - 26 V DC, protected against reverse polarity, electrically isolated, 1000 V insulation voltage, or 230 V 50/60 Hz Power consumption: Approx. 3 W / 3 VA Protection class: IP 65 Housing: Surface-mounted housing (polycarbonate) 120 x 122 x 57 mm Connections: 4 x M16 cable entries on the bottom of the housing.

€584.65*
3 meter connection cable for N-LF measuring cells, 4-core 0.25² with shielding
Product number: 880652
Cable length: 3 meters
- 1 side connected to solenoid valve connector without seal ("Plug and Play", as plug only has to be plugged onto measuring cell)- 1 side labelled cable with wire end ferruleswhite: PT100brown: PT100yellow: Measuring cell SL green: Measuring cellblue: shielding

€46.71*