JUMO contact resistance thermometer with connection cable, protective fitting aluminium (25 x 50 mm)

Article number: 802087
Our service hotline – We are here for you 📞 +49 (0) 5121 7609 99

Product information "JUMO contact resistance thermometer with connection cable, protective fitting aluminium (25 x 50 mm)"

Surface-Mounted Resistance Thermometer with Pt100 and Tolerance Class B according to DIN EN 60751 with Temperature Range -50 to +260 °C

JUMO Surface-Mounted Resistance Thermometer with PTFE Connection Cable, Aluminium Protection Fitting (25 x 50 mm), Type: 902550/30-378-1003-1-11-2500/315

This version of the thermometer from JUMO is suitable for indirect temperature measurement on pipes and other surfaces. Equipped with a Pt100 in a two-wire circuit, PTFE connection cable and bend protection spring, this version is especially suitable for quickly mounted surface measurements from -50 to +260 °C.

This version is intended for surface measurements where the temperature should be recorded quickly and without interfering with the system. The surface-mounted resistance thermometer is mounted externally at the measuring point and is therefore particularly suitable for closed pipe systems as well as flat or round surfaces.

Technical Data

  • Version: Surface-mounted resistance thermometer with connection cable
  • Protection fitting: Aluminium, 25 x 50 mm
  • Sensor insert: 1× Pt100
  • Circuit type: Two-wire circuit
  • Tolerance class: Class B according to DIN EN 60751
  • Connection cable: PTFE
  • Temperature range: -50 to +260 °C
  • Connection cable end: Ferrules according to DIN 46228 Part 4
  • Connection cable length: 2500 mm
  • Type extension: Bend protection spring

Advantages and Technical Features of the Surface-Mounted Resistance Thermometer

  • temperature measurement without interfering with the system
  • aluminium protection fitting 25 x 50 mm for efficient heat transfer
  • fast and uncomplicated surface installation
  • well suited for round and flat measuring points
  • bend protection spring for additional cable transition protection

The aluminium protection fitting in the size 25 x 50 mm makes this version particularly interesting where efficient heat transfer and a compact contact surface are required. Aluminium supports rapid detection of surface temperature, while the low thermal mass helps the measurement respond quickly to temperature changes.

Temperature measurement is carried out using a 1× Pt100 in a two-wire circuit. Combined with the PTFE connection cable, this version is designed for temperatures from -50 to +260 °C. This makes it suitable for applications where higher surface temperatures may also occur. The 2500 mm long connection cable provides sufficient flexibility for installation and connection to the evaluation system.

A practical advantage of this version is its simple installation. Mounting can be carried out using tension bands or hose clamps, eliminating the need for mechanical processing of the measuring point. This is especially helpful for existing systems or retrofitted measuring points. The type extension with bend protection spring additionally protects the cable transition and makes the design more robust for daily use.

Since the temperature is measured indirectly via the surface, the measurement remains unaffected by pressure, flow conditions or chemical influences in the medium. In cases of larger temperature differences between the medium and the surrounding environment, additional insulation may be beneficial. Thermal paste can also optionally be used to further improve heat transfer.

Typical Applications

  • surface measurement on closed pipe systems
  • temperature detection on flat metal surfaces
  • applications with retrofittable measuring points
  • technical systems without direct contact with the medium

Dimensions

Height 2,5 cm
Length 23 cm
Width 20 cm

Weight

Weight 118 g

Other attributes

Anschlussleitung Silikon
Country of origin DE
Customs tariff number 90251900
Messeinsatz 1x Pt 100 Zweileiterschaltung
Temperaturbereich -50°c ... +180°C
Technical data:
Technical specifications Description
Connection Cable ends tinned, available with ferrule terminals, plug-in sleeves or multi-pin connectors
connection cable
  • Silicone, ambient temperature -50 to +180 °C
  • PTFE, ambient temperature -190 to +260 °C
  • Kapton, ambient temperature -50 to +260 °C
Terminal box
  • Basic model 902554/41 and 902554/42: PC plastic housing, colour: silver-grey/blue
  • Basic model 902554/44: PC plastic housing, colour: white
  • Connection via screw terminals; basic model 902554/44 is available with spring-loaded terminals as an option when selected without a transducer
protective tube Stainless steel 1.4571, aluminium, plastic
Gauge insert Pt100 temperature sensor, DIN EN 60751, Class B, two-wire circuit
Transducer Optional for base model 902554/44: analogue transmitter, 4 to 20 mA or 0 to 10 V
Transmitter
Characteristic Output 4 to 20 mA Output 0 to 10 V
Input
Measuring input Pt100 (DIN EN 60751) Pt100 (DIN EN 60751)
Sensor current ≤0,5 mA ≤0,5 mA
Measuring rate Continuous measurement, due to analogue signal path. Continuous measurement, due to analogue signal path.
Measuring circuit monitoring
Underrange (measuring range underrun) decreasing down to ≤ 3,6 mA 0 V
Overrange (measuring range overrun) rising to ≥ 22 up to < 28 mA
(typically 24 mA)
rising to ≥ 11 up to < 14 V
(typically 12 V)
Sensor short circuit ≤ 3,6 mA 0 V
Sensor and cable break ≥ 22 to < 28 mA (typically 24 mA) ≥ 11 to < 14 V (typically 12 V)
Output
Output signal Pulsed direct current 4 to 20 mA DC voltage 0 to 10 V
Transfer behaviour temperature-linear temperature-linear
Transmission accuracy ≤ ±0,1 % ≤ ±0,2 %
Attenuation of the residual ripple of a 24 V power supply, amplitude 10 V / 50 Hz, load 470 Ω / 10 MΩ load 37 dB 40 dB
Load (Rb) Rb = (Ub - 7,5 V) ÷ 22 mA -
Load effect ≤ ±0,02 % / 100 Ωa -
Load / Load Influence - ≥ 10 kΩ / ≤ ±0,1 %
Settling time after temperature change ≤ 10 ms ≤ 10 ms
Calibration conditions DC 24 V / approx. 22 °C DC 24 V / approx. 22 °C
Calibration accuracy ≤ ±0,2 %a,b or ≤ ±0,2 K ≤ ±0,2 %a,b or ≤ ±0,2 K
Overall sensor accuracy/Calibration ±0,4 K (typical) at 20 °C / 24 V
Power supply
±0,4 K (typical) at 20 °C / 24 V
Power supply
Power supply
Power supply (Ub) DC 7,5 at 30 V DC 15 at 30 V
Reverse polarity protection yes yes
Power supply influence ≤ ±0,01 %/V Deviation from 24 Va ≤ ±0,01 %/V Deviation from 24 Va
Environmental influences
Operating temperature range -40 to +85 °C -40 to +85 °C
Lagertemperaturbereich -40 to +100 °C -40 to +100 °C
Temperature influence ≤ ±0,01 %/K deviation from 22 °C a ≤ ±0,01 %/K deviation from 22 °C a
Climatic resistance
similar to DIN EN 60654 class C1
relative humidity ≤ 95% annual average without condensation relative humidity ≤ 95% annual average without condensation
EMC emissions and immunity EN 61326 class B, industrial requirements EN 61326 class B, industrial requirements

a All specifications refer to the full-scale value of 20 mA.
b The higher value applies.

Approvals / certifications
Certification marks Testing body Certificate / test number Basis for audit Applies to
SIL QUALIFIED
PL QUALIFIED
Type suffix 058
in conjunction with the manufacturer's declaration