Skip to main content Skip to search Skip to main navigation

Testomat® Limit TH 0.3–8 bar; 24 V DC

Product number: 100900
Our service hotline – We are here for you 📞 +49 (0) 5121 7609 99

Product information "Testomat® Limit TH 0.3–8 bar; 24 V DC"

Testomat® Limit TH – Precise Water Hardness Monitoring for Maximum Process Reliability
Our new Testomat Limit TH is a limit-value measuring device that automatically monitors residual total hardness (water hardness) in water. It is your reliable online analyzer for continuous monitoring of residual total hardness in the range of 0.05–25.0 °dH. You can continue to use all hardness indicators from the proven Testomat® 2000 series. With intuitive touchscreen operation and clear menu navigation, it enables easy handling and quick setup. The device is ideal for water treatment applications in reverse osmosis systems, softening plants, electroplating, large kitchens, laundries and industrial processes. Testomat® Limit TH supports up to 72 hours of operation without constant supervision and automatically informs you about the indicator fill level for uninterrupted measurements. With a short analysis time of only 2 minutes and flexible settings for limit values and measuring intervals, it ensures maximum efficiency. Integrated logging of limit exceedances and alarm messages provides transparency and safety for your processes. For precise results, we recommend using original Heyl indicators and spare parts—ensuring reliable operation and full warranty coverage. Order online now and benefit from a 3% discount in the HeylNeomeris shop. When purchasing a Testomat Limit device, you also receive a hardness indicator of your choice free of charge. Secure the future of water hardness monitoring with the new Testomat® Limit TH—reliable, convenient and future-ready.

Testomat Limit TH

Online analyzer for water hardness

The Testomat Limit TH is your reliable limit-value measuring device for automatic monitoring of residual total hardness (water hardness) in water. It is a compact analyzer for online water hardness measurement based on the principle of “limit monitoring with color change” within a measuring range of 0.05 – 25.0 °dH. Our customers appreciate the easy operation of the new device. With touchscreen and drop-down menus, it is simple to use.

Power Supply Note

The Testomat LIMIT TH 0–3/8 bar is operated with 24 V DC. To connect it to 230 V mains power, a separate plug-in power supply is required (including EU primary adapter). The plug-in power supply is not included in the scope of delivery and can be ordered separately under item number 30996.

Areas of application:

The Testomat Limit TH was designed for use in water treatment (e.g., reverse osmosis systems, electroplating, large boiler systems, laundries, large kitchens and softening plants). The device is a limit-value measuring instrument that automatically monitors residual total hardness (water hardness) in water.

The analysis result is displayed in color in the “Measured Values” menu. Limit value not exceeded = green frame, limit value exceeded = double red frame.

Limit value: You can set the limit value you wish to monitor yourself. The adjustable limit range depends on the indicator type. For use with Testomat Limit TH devices, indicators with different measuring ranges are available to match your operational requirements. Within the indicator’s measuring range, the limit value to be monitored can be freely set. All indicator types are available in two container sizes (100 ml and 500 ml). A detailed list of suitable indicators with the corresponding item numbers can be found below.

Product benefits:

Self-test and continuous self-monitoring: The device status is displayed. Testomat Limit TH performs a self-test when switched on and continuously monitors itself during operation.

72-hour operation without constant supervision: Testomat Limit TH automatically indicates whether sufficient indicator is available for continuous measurement. Taking into account the remaining indicator volume, the set interval pause and the indicator amount consumed per measurement, the device calculates whether the remaining quantity is sufficient for the next 72 operating hours.

Automatic display of the indicator fill level

Logging of limit undercuts and exceedances with date and time.

Logging of alarm or error messages with date.

Flexible configuration of limit values and measuring intervals

Free choice of hardness units in °dH, °f, ppm CaCO3 or mmol/l.

Short analysis time: approx. 2 minutes

Short measuring time: approx. 4 minutes per analysis

Technical highlights:

  • Adjustable limit range: limit values for residual hardness from 0.05 – 25.0 °dH depending on the selected indicator
  • Interval operation: 0 – 60 minutes, plus manual start or external control
  • Long operating times thanks to 500 ml indicator reserve (>1000 measurements)
  • SD card for measurement data logging and firmware updates
  • 4–20 mA interface for transmitting measured values
  • Optional retrofit pump (40692) for automatic cleaning of the measuring chamber

Why original Heyl indicators and spare parts?

For reliable operation and precise measurement results, use only original Heyl indicators and original Heyl spare parts. Third-party indicators and spare parts can lead to measurement errors and damage. If other indicators or spare parts are used, the device warranty becomes void.

Certificates & approvals:

Conformity:

CE

EN 61326-1 Electrical equipment for measurement, control and laboratory use – EMC requirements

EN 61010-1 Safety requirements for electrical equipment for measurement, control and laboratory use

UK

CA

BS EN IEC 61326-1 Electrical equipment for measurement, control and laboratory use – EMC requirements – General requirements

BS EN 61010-1+A1 Safety requirements for electrical equipment for measurement, control and laboratory use

Protection rating: IP 44

Important notes

  • To ensure proper device operation, regular maintenance is required (every six months to annually).
  • Operate only with the specified DC voltage.

Order now and monitor water hardness reliably!

Secure your 3% online shop discount.

When purchasing a Testomat Limit device, you will also receive a free hardness indicator of your choice.

Do you have any questions about the product?

We will be happy to answer your questions by phone as well.

Download:

Bedienungsanleitung

User manual

Mode de emploi

Gebruiksaanwijzing

Testomat Limit Flyer

Testomat Limit Flyer in English

Dimensions

Height 32,3 cm
Length 13,8 cm
Width 42,4 cm

Weight

Weight 5,6 kg

Other attributes

Country of origin EU
Customs tariff number 90278017
Technical data
Technical Data
property value
Power supply 24V DC current

Device protection 24 V: T0,8 A
Power consumption max. 16 VA, without external load
Protection class II
Protection type IP 44
Conformity EN 61326-1, EN 61010-1
BS EN IEC 61326-1, BS EN 61010-1+A1
Ambient temperature 10 – 40 °C
Measuring range Residual hardness in the range of 0,05 – 25,0 °dH . See Chapter 3.1 Available reagents
Contact load relay 28VDC/300W or 45VAC/300W ohm resistive load
Current interface Output of defined values (5, 8, 11, 14, 17, 20 mA) for displaying status and error messages, max. load 500 Ohms
Serial interface RS232 9600 Baud, 8 Bit, 1 stop bit, no parity
SD card Format FAT or FAT32 , max. 32GByte
Dimensions W x H x D = 424 x 323 x 138 mm
Weight 4500 g
Other The device is protected against reverse polarity.
Water connection
property value
Working pressure* 1 - 8 bar / 1 x 105 to 8 x 105 Pa *
Water intake Opaque pressure hose with external diameter 6/4x1 mm
Water drain Hose with internal diameter 12 mm
Water temperature 10 – 40 °C
*Under 1 bar pressure, a flow rate of 400 ml/min must be achieved for safe operation!
Skip product gallery

We recommend our indicators

Testomat® Indicator TH2005 500ml, bottle with product label and measuring range 0.05–0.50 °dH, water quality test
Testomat® indicator TH 2005, 500ml
Product number: 152005

Testomat Indicator TH2005 – Residual Hardness Measurement Original indicator for precise determination of residual hardness in water The Testomat Indicator TH2005 from Heyl, 500 ml, is an original measurement solution for determining residual hardness in water. The indicator ensures high measurement accuracy and reliability for daily use. Measurements are provided in standardized units (°dH, °f, ppm CaCO₃, and mmol/l). Order online now and benefit from a 3% discount in the online shop on Heyl products. The indicator is specifically designed for residual hardness monitoring in water treatment. It is suitable for continuous process control and stable water quality. Advantages of the Original Testomat TH2005 Indicator The Testomat Indicator TH2005 offers a wide range of benefits for reliable residual hardness monitoring in demanding applications: High accuracy in the low range: Specifically designed for precise determination of very low residual hardness from 0.05 to 0.50 °dH. Reliable color reaction: Clear and reproducible color changes allow secure monitoring of residual hardness. Versatile display units: Measurement in °dH, °f, ppm CaCO₃, and mmol/l – ideal for international and industrial applications. Optimal device compatibility: Precisely calibrated for the Testomat 2000 series, the new Testomat Limit from Heyl, and other compatible Testomat devices. Suitable for continuous operation: Designed for ongoing process control in water treatment, industry, and supply technology. Heyl original quality: Ensures proper device operation and retention of warranty and guarantee claims. Where can the TH2005 indicator be used? It is suitable for water treatment, industry, and supply technology. Compatible with the following devices: Testomat 2000 Testomat 2000 CAL Testomat 2000 DUO Testomat 2000 V Testomat 2000 self clean Testomat ECO Testomat ECO-PLUS Testomat EVO TH Testomat Limit Which measurement ranges does the TH2005 indicator cover? 0.05–0.50 °dH with 0.01 resolution 0.09–0.89 °f 0.89–8.93 ppm CaCO₃ 0.01–0.09 mmol/l

€124.00*
Testomat® Indicator TH2005, 2 bottles side by side, measurement of residual hardness in water
Testomat® indicator TH 2005 2x100ml
Product number: 151005

Testomat® Indicator TH2005 from Heyl – Precise Low-Range Residual Hardness Measurement 2x100 ml Residual hardness 0.05–0.50 °dH for Testomat 2000 2x100 ml Testomat Indicator TH2005, 2x100 ml bottles, for measuring residual hardness. The original bottles allow direct use without transferring the solution. The Testomat® Indicator TH2005 is an original indicator solution for reliable measurement and threshold monitoring of residual hardness in the range of 0.05 to 0.50 °dH. Supplied in two practical 100-ml original bottles, the indicator enables direct application without transferring. The indicator is particularly suitable for applications with high water quality requirements, where precise monitoring of low hardness ranges is essential. Which devices is the TH2005 indicator from Heyl compatible with? The TH2005 indicator is compatible with the following measuring devices: Testomat 2000® Testomat 2000® CAL Testomat 2000® DUO Testomat 2000® V Testomat 2000® self clean Testomat ECO® Testomat ECO®-Plus Testomat® EVO TH Testomat® Limit Which values does the original TH2005 indicator from Heyl measure? The Testomat® Indicator TH2005 covers multiple units and offers high resolution: 0.05–0.50 °dH (Resolution 0.01) 0.09–0.89 °f (Resolution 0.02) 0.89–8.93 ppm CaCO₃ (Resolution 0.2) 0.01–0.09 mmol/l (Resolution 0.01) Using the original indicator ensures high measurement accuracy, proper device operation, and retention of warranty and guarantee claims.

€105.67*
Testomat Indicator TH2025 500ml Front view with white label, 500 ml bottle for measuring residual hardness in water
Testomat® indicator TH 2025 500ml
Product number: 152025

Testomat Indicator TH2025 – for Determining Residual Hardness Precise Residual Hardness Measurement with the TH 2025 for Testomat 2000 and Testomat Limit The Testomat Indicator TH2025 from Heyl is a chemical reagent solution for precise determination of residual hardness. It measures in various units (°dH, °f, ppm CaCO₃, and mmoI/I). Enjoy a 3% discount on Heyl products when ordering online in our HeylNeomeris Shop. With the TH2025 indicator, you can determine residual hardness in the range of 0.25 to 2.50 °dH. The 500 ml bottle provides a convenient dosing solution that can be used directly in the measuring device without any complex preparation. Where can the TH2025 Indicator be used? The indicator is suitable for: Testomat 2000 Testomat 2000 CAL Testomat 2000 DUO Testomat 2000 V Testomat 2000 self clean Testomat ECO Testomat ECO-PLUS Testomar EVO TH Testomat Limit What are the measurement ranges? 0.25–2.50 °dH, with a resolution of 0.05 0.45–4.48 °f, with a resolution of 0.10 4.48–44.8 ppm CaCO₃, with a resolution of 0.9 0.04–0.45 mmoI/I, with a resolution of 0.01

€124.00*
Testomat® Indicator TH2025 2x100 ml bottles, slightly angled view, water indicator for measuring residual hardness
Testomat® indicator TH 2025 2x100ml
Product number: 151025

2x100 ml bottles original Testomat® indicator TH 2025 for limit value: 0,25- 2,50°dH for measuring residual hardness.  °dH (resolution): 0,25- 2,50 (0,05) °f (resolution): 0,45-4,48 (0,10) ppm CaCO3 (resolution): 4,48-44,8 (0,9) mmol/l (resolution): 0,04-0,45 (0,01)

€105.67*
Testomat® Indicator TH2050 500 ml for testing water hardness
Testomat® indicator TH2050 500ml
Product number: 152050

The 500 ml bottle of original Testomat® indicator TH 2050 for the limit value 0.5 - 5.0 °dH only for Testomat® EVO TH and Testomat® LAB TH.

€128.16*
Testomat® indicator TH2050 2x100ml
Product number: 151050

The 100 ml bottle of original Testomat® indicator TH 2050 for the limit value 0.5- 5,0°dH only for Testomat® EVO TH. One packing unit contains 2 bottles á 100ml.

€105.67*
500ml bottle of Testomat® TH2100 with product label
Testomat® indicator TH 2100 500ml
Product number: 152100

Testomat Indicator TH2100 for Determining Elevated Residual Hardness Indicator solution for precise monitoring of residual hardness in the higher limit range 1.00–10.00 °dH The Testomat Indicator TH2100 from Heyl, 500 ml bottle, is an original indicator solution for determining residual hardness in the higher hardness range of 1.00–10.00 °dH in water treatment systems. The bottles are designed for use in Testomat devices and enable continuous and reliable monitoring. The TH2100 indicator is specifically designed for higher residual hardness levels. It supports safe process control in industrial and commercial water treatment systems. What measurement ranges does the TH2100 indicator cover? 1.00–10.00 °dH, resolution 0.20 1.79–17.9 °f, resolution 0.40 17.9–179 ppm CaCO₃, resolution 3.8 0.18–1.79 mmoI/I, resolution 0.04 Which Heyl Testomat devices is the indicator suitable for? The indicators are suitable for: Testomat 2000® Testomat 2000® CAL Testomat 2000® DUO Testomat 2000® V Testomat 2000® self clean Testomat ECO® Testomat ECO®-Plus Testomat® EVO TH Testomat Limit

€128.16*
Testomat® Indicator TH2100, two 100 ml bottles with screw caps, water analysis measuring solution
Testomat® indicator TH 2100 2x100ml
Product number: 151100

2x100 ml bottles original Testomat® indicator TH 2100 for limit value:1,00-10,00°dH°dH for measuring residual hardness. °dH (resolution): 1,00-10,00 (0,20) °f (resolution): 1,79-17,9 (0,40) ppm CaCO3 (resolution): 17,9-179 (3,8) mmol/l (resolution): 0,18 -1,79 (0,04)

€105.67*
Testomat® indicator TH2250 500 ml bottle for measuring water hardness, clearly legible label
Testomat® indicator TH 2250 500ml
Product number: 152250

Original Indicator Testomat Indicator TH2250 in the 500 ml Bottle from Heyl Precise Residual Hardness Measurement for Testomats The Testomat Indicator TH2250, 500 ml bottle, measures residual hardness in water samples and is suitable for use in our measuring devices Testomat 2000, Testomat EVO, and the new limit measuring device Testomat Limit. The measuring range is 2.50–25.00 °dH with a resolution of 0.50. Thanks to precise measurements, it supports compliance with quality standards in industrial water treatment. It is designed for long service life, minimizing maintenance and downtime. The TH2250 indicator allows reliable, automatic determination of residual hardness in water. What limit values can be measured with the TH2250? 2.50–25.00 °dH, resolution 0.50 4.48–44.8 °f, resolution 0.40 44.8–448 ppm CaCO₃, resolution 3.8 0.45–4.48 mmoI/I, resolution 0.04 Where can the indicator be used? The indicators are suitable for: Testomat 2000® Testomat 2000® CAL Testomat 2000® DUO Testomat 2000® V Testomat 2000® self clean Testomat ECO® Testomat ECO®-Plus Testomat® EVO TH Testomat Limit

€128.16*
Testomat® Indicator TH2250, double pack 2 x 100 ml, limit value 2.50–25.00 °dH, water quality test
Testomat® indicator TH 2250 2x100ml
Product number: 151250

2x100 ml bottles original Testomat® indicator TH 2250 for limit value: 2,50-25,00°dH for measuring residual hardness.    limit value: °dH (resolution): 2,50-25,00 (0,50) °f (resolution): 4,48-44,8 (0,40) ppm CaCO3 (resolution): 44,8-448 (3,8) mmol/l (resolution): 0,45 -4,48 (0,04)

€105.55*
Skip product gallery

Recommended accessories

Service set Testomat Limit, our item number 270339, entire contents shown
Testomat® Limit TH maintenance kit for Testomat® LIMIT
Product number: 270339

HeylNeomeris offers you the right maintenance set for your Testomat Limit, with all the components you need for smooth and efficient upkeep. The set consists of: 2 x O-Ring 3x1 EPDM 70, black for Testomat LIMIT  order code: 33764 1 x O-Ring 18x2 EPDM order code: 33776 2 x O-Ring 1,78x1,78  order code: 11245 1 x Sight glass for Testomat LIMIT  order code: 37517 1 x Sight glass with Nut for Testomat LIMIT  order code: 40675 1 x Magnetic stirrer order code: 40050 1 x Inlet hose 1/4 for Testomat LIMIT  order code: 40683 1 x Drain hose 1/4 PE for Testomat LIMIT  order code: 40684 1 x Filter sieve for inlet 19.5dx25 (260µ mesh size)  order code: 11217 1 x Flow regulator core  order code: 11225 1 x Cleaning brush set  Order code: 32287

€395.56*
Annual Service Set Testomat Limit TH our item number 270359
Annual service kit Testomat® Limit TH
Product number: 270359

The annual service set for your Testomat Limit is perfectly designed to ensure that you always have all the regularly replaceable components at hand. For reliable and regular maintenance. The set consists of: 1 x Flat seal 24x2 EPDM code number: 33777 1 x Sight glass with groove  code number: 40675 1 x Mirror disc for Testomat LIMIT  code number: 37517 1 x O-ring 18x2  code number: 33776 1 x Magnetic stirrer for measurement chamber recording  code number: 40050

€347.00*
Retrofit kit for Selfclean function for Testomat LIMIT
Product number: 40681

The Selfclean function from Heyl allows cleaning cycles to be carried out independently through an additional dosing pump. Through continuous cleaning, it is ensured that the measurement results are not distorted. In addition, maintenance effort is reduced and the lifespan of your Testomat LIMIT is extended. Delivery includes The expansion kit (item no. 40681) for installing a second pump for the cleaning function consists of the following components: 1) Pump with motor (fully pre-assembled) 2) 1 beak valve (item no. 33805) at the outlet) 3) 1 large O-ring ø 11 x 1 (item no. 33716) 4) 1 small O-ring ø 1.78 x 1,78 (item no. 11245) 5) 1 casing (item no. 33752) 6) 1 beak valve (item no.. 33805) at the inlet 7) 2 screws (item no. 33028) for attaching the pump (already provided) 8) 1 tube 250 mm (item no. 40433) Suction side to the bottle with cleaning fluid 9) 1 tube 250 mm (item no. 40433) Pressure side to the measuring chamber 10) 2 screws (item no. 33028) for attachment to the control unit (already provided) Download Einbauanleitung_Testomat Limit_SelfClean-Pumpe Installation instructions_Testomat Limit_SelfClean pump Instructions de installation_Pompe Testomat Limit_SelfClean Installatiehandleiding_Testomat Limit_SelfClean-pomp

€446.85*
Testomat® Self Clean cleaning solution 500 ml bottle with label on front, cleaning solution for measuring chamber
Testomat 2000® Self clean cleaning reagent
Product number: 151105

Cleaning reagent in 500ml-bottle for Testomat 2000® Self clean Testomat 2000® self clean is a special version of Testomat 2000® with an additional dosing pump for cleaning or disinfecting agents after an analysis. It can be used to remove possible pollution of the measuring chamber and the drain hose. After a preset number of analysis cycles, the measuring chamber is rinsed and the agent is added to the water in the measuring chamber. After a reaction time of 30 seconds, the content of the measuring chamber is dumped. The measuring chamber is subsequently rinsed twice.    

€99.01*
Connection set for Testomaten 2000, ECO, EVO, LAB with plastic pipe, drain hose, ball valve, reducer connector and a reducer nipple
Connection Set for Testomat 2000® / ECO / EVO / LAB / Limit
Product number: 40187

In diesem Anschluss-Set ist alles enthalten, was Sie für den schnellen Anschluss des Testomat 2000®- oder Titromat®-Gerätes benötigen.   Inhalt: 5 m Kunststoffrohr PE 6/4x1,blau 2 m Ablaufschlauch di = 12 mm 1 Kugelhahn, PPSV 011223W 1 Reduzier-Verbinder 10 auf 6 mm 1 Reduziernippel 3/8"-1/2"

€180.29*
Pressure regulator kit suitable for all Testomats. With pressure gauge, retaining bracket with nut, straight screw-in fittings, approved for municipal and soft water.
Pressure regulator - selfassembly kit
Product number: 880505

The pressure regulator is suitable for all Testomat® devices. It is used for pressures from 0.5 to 10 bar in order to avoid any pressure fluctuations that may occur and to ensure an optimum operating pressure. Kit consisting of: Pressure gauge, rear connection Bracket with nut 2 x straight screw-in fittings 1/4 ‘ x 6 mm  Technical data: max. inlet pressure: 25 bar Ambient temperature: 0-50 °C Pressure gauge connection G 1/4 Weight: 200 g  City water: approved Soft water: approved Demineralised water: not approved Condensate: not authorised

€206.77*
Plug-in power supply for Testomat® LIMIT, our item number 30996
Plug-in power supply including primary adapter (EU) complete for Testomat® LIMIT
Product number: 30996

The plug-in power supply is delivered complete with a primary adapter (EU) for use with the Testomat® LIMIT. After replacing the adapter, the plug-in power supply can also be used in other countries and therefore worldwide. Simply attach the required adapter to the power supply. Available replacement adapters for: UK – our item number: 30935 US – our item number: 30936 EU – our item number: 30969 can be found in our shop. Supplementary Power Supply for Operating the Testomat LIMIT This plug-in power supply including EU primary adapter is required to operate the Testomat LIMIT reliably with 230 V mains voltage. It ensures the correct power supply and enables proper operation of the device in mains-powered applications. The Testomat LIMIT is supplied without an integrated power supply. For applications where no alternative power source is available, this power supply is the required supplementary component. Your Benefits Suitable for operating the Testomat LIMIT with 230 V AC Complete set including EU primary adapter Safe and stable power supply Easy commissioning without additional components Note For mains operation of the Testomat LIMIT at 230 V, this plug-in power supply is mandatory.

€412.57*