Typical Applications and Selection Guide for pH and Redox Measurements
Electrodes and sensors are key components for accurate measurement of pH values and redox potentials in various applications. To help you find the right sensors for your measurement tasks, we offer a practical selection guide with typical use cases and important criteria.
Typical applications:
- Monitoring water quality in drinking and wastewater systems
- Process control in chemical and pharmaceutical industries
- Control and regulation in food and beverage production
- Environmental analytics and water body monitoring
- Water Analyzers
- Liquid chemistry
- Controls
-
Electrodes and sensors
- Manufacturer
- Parameter
-
Typical application (selection guide for pH / ORP)
- Water and process measurement technology
- Waste water, heavily contaminated media, chemical industry, suspensions, lacquers
- High temperature and sterilisation applications
- Swimming bath and pool
- Cooling tower
- Power plants, waste incineration plants, galvanisation
- Aquaristics, marine aquaristics
- Rainwater, pond and surface water, greenhouse
- Drinking water monitoring and treatment
- Accessories
- Hand-held measuring instruments and analysis cases
- Laboratory Benchtop Meters
- NeoTec World
- Permeate
- Clinical Solutions
- Seminars & Webinars
- Ozone and UV technology
- Dosing pumps
- Gas Measuring Instruments
- Hygiene and Disinfection
- Water Meters
- Accessories
- Blog
Filter products
high-quality industrial electrodesprocess/industrial applicationsadditional integrable temperature sensordifferent insertion lengthsspecial types on request
high-quality industrial electrodesprocess/industrial applicationsadditional integrable temperature sensordifferent insertion lengthsspecial types on request
Typical areas of applicationProcesses with higher continuous temperatures (up to a maximum of 135 °C)Sterilisation applicationsDouble chamber design in the presence of electrode poisonsfluoride-containing (hydrofluoric acid-containing) media up to 1000 mg HF/lSpecial featuresproven JUMO HT glass (pH high-temperature membrane glass) 0 ... 14 pHJUMO DS membrane glass for sterilization applicationsCartridge discharge system with silver ion-free reference electrolyte (gel)Pressure-resistant versions up to 10 bar (50 °C)Temperature range: 0 ... 135 °C1Temperature sensors can be integrated as an optionORP versions with platinum or gold cap up to ±2000 mV
Typical areas of applicationProcesses with higher continuous temperatures (up to a maximum of 135 °C)Sterilisation applicationsDouble chamber design in the presence of electrode poisonsfluoride-containing (hydrofluoric acid-containing) media up to 1000 mg HF/lSpecial featuresproven JUMO HT glass (pH high-temperature membrane glass) 0 ... 14 pHJUMO DS membrane glass for sterilization applicationsCartridge discharge system with silver ion-free reference electrolyte (gel)Pressure-resistant versions up to 10 bar (50 °C)Temperature range: 0 ... 135 °C1Temperature sensors can be integrated as an optionORP versions with platinum or gold cap up to ±2000 mV
Typical areas of applicationProcesses with higher continuous temperatures (up to a maximum of 135 °C)Sterilisation applicationsDouble chamber design in the presence of electrode poisonsfluoride-containing (hydrofluoric acid-containing) media up to 1000 mg HF/lSpecial featuresproven JUMO HT glass (pH high-temperature membrane glass) 0 ... 14 pHJUMO DS membrane glass for sterilization applicationsCartridge discharge system with silver ion-free reference electrolyte (gel)Pressure-resistant versions up to 10 bar (50 °C)Temperature range: 0 ... 135 °C1Temperature sensors can be integrated as an optionORP versions with platinum or gold cap up to ±2000 mV
Typical areas of applicationindustrial waste water technologyprocess measurements, electroplating, paper industry, beverage industryoily waste watersuspensions, lacquers, media with solid particlesDouble-chamber design in the presence of electrode poisonsFluoride-containing (hydrofluoric acid-containing) media up to 1000 mg/l HFSpecial featuresDirt-repellent PTFE ring diaphragm with highly viscous KCl solution (gel) or perforated or annular gap diaphragm with polymerised solid electrolyte - practically blockage-freeCartridge discharge system with silver ion-free reference electrolytePressure-resistant versions up to 10 bar (50 °C)Temperature range: see order detailsOptional temperature sensors can be integratedOptional salt reservoir to increase service life in media with low conductivity
Typical areas of applicationindustrial waste water technologyprocess measurements, electroplating, paper industry, beverage industryoily waste watersuspensions, lacquers, media with solid particlesDouble-chamber design in the presence of electrode poisonsFluoride-containing (hydrofluoric acid-containing) media up to 1000 mg/l HFSpecial featuresDirt-repellent PTFE ring diaphragm with highly viscous KCl solution (gel) or perforated or annular gap diaphragm with polymerised solid electrolyte - practically blockage-freeCartridge discharge system with silver ion-free reference electrolytePressure-resistant versions up to 10 bar (50 °C)Temperature range: see order detailsOptional temperature sensors can be integratedOptional salt reservoir to increase service life in media with low conductivity
High-quality industrial electrodesprocess/industrial applicationsadditional integrable temperature probedifferent installation lengthsspecial types on request
Typical areas of applicationindustrial waste water technologyprocess measurements, electroplating, paper industry, beverage industryoily waste watersuspensions, lacquers, media with solid particlesDouble-chamber design in the presence of electrode poisonsFluoride-containing (hydrofluoric acid-containing) media up to 1000 mg/l HFSpecial featuresDirt-repellent PTFE ring diaphragm with highly viscous KCl solution (gel) or perforated or annular gap diaphragm with polymerised solid electrolyte - practically blockage-freeCartridge discharge system with silver ion-free reference electrolytePressure-resistant versions up to 10 bar (50 °C)Temperature range: see order detailsOptional temperature sensors can be integratedOptional salt reservoir to increase service life in media with low conductivity
Typical areas of applicationindustrial waste water technologyprocess measurements, electroplating, paper industry, beverage industryoily waste watersuspensions, lacquers, media with solid particlesDouble-chamber design in the presence of electrode poisonsFluoride-containing (hydrofluoric acid-containing) media up to 1000 mg/l HFSpecial featuresDirt-repellent PTFE ring diaphragm with highly viscous KCl solution (gel) or perforated or annular gap diaphragm with polymerised solid electrolyte - practically blockage-freeCartridge discharge system with silver ion-free reference electrolytePressure-resistant versions up to 10 bar (50 °C)Temperature range: see order detailsOptional temperature sensors can be integratedOptional salt reservoir to increase service life in media with low conductivity
Typical areas of applicationindustrial waste water technologyprocess measurements, electroplating, paper industry, beverage industryoily waste watersuspensions, lacquers, media with solid particlesDouble-chamber design in the presence of electrode poisonsFluoride-containing (hydrofluoric acid-containing) media up to 1000 mg/l HFSpecial featuresDirt-repellent PTFE ring diaphragm with highly viscous KCl solution (gel) or perforated or annular gap diaphragm with polymerised solid electrolyte - practically blockage-freeCartridge discharge system with silver ion-free reference electrolytePressure-resistant versions up to 10 bar (50 °C)Temperature range: see order detailsOptional temperature sensors can be integratedOptional salt reservoir to increase service life in media with low conductivity
high-quality industrial electrodesprocess/industrial applicationsadditional integrable temperature sensordifferent insertion lengthsspecial types on request
high-quality industrial electrodesprocess/industrial applicationsadditional integrable temperature sensordifferent insertion lengthsspecial types on request
high-quality industrial electrodesprocess/industrial applicationsadditional integrable temperature sensordifferent insertion lengthsspecial types on request
high-quality industrial electrodesprocess/industrial applicationsadditional integrable temperature sensordifferent insertion lengthsspecial types on request
Version: Glass shaft UW glassPTFE- ring diaphragmScrew head Pg 13,5 (S8)120mmSalt reservoirType code (shown on the electrode as well):201020/51-18-04-22-120/837 ; Part Nr. 321035
General descriptionThe electrodes are characterised by high mechanical and chemical resistance. Due to the stable PVDF body, there is practically no risk of the sensor breaking. The electrolyte of these combination electrodes guarantees a stable measured value, even in critical media containing sulphite.A Pt1000 temperature sensor is integrated. Depending on the application, the electrodes can be manufactured as pH or redox electrodes. An open annular gap diaphragm is used as the diaphragm.Areas of applicationChemical industryWaste water treatmentSewage treatmentPaper industrySelected version:Basic type: JUMO tecLine PRO pH combination electrodeBasic type extension: Process electrodeActive part: HT glassDiaphragm: annular gap diaphragmElectrical connection to electrode: Screw head Pg13.5Extra codes: Salt reserveOrder code: 201020/79-12-10-22/837
General descriptionThe electrodes are characterised by high mechanical and chemical resistance. Due to the stable PVDF body, there is practically no risk of the sensor breaking. The electrolyte of these combination electrodes guarantees a stable measured value, even in critical media containing sulphite.A Pt1000 temperature sensor is integrated. Depending on the application, the electrodes can be manufactured as pH or redox electrodes. An open annular gap diaphragm is used as the diaphragm.Areas of applicationChemical industryWaste water treatmentSewage treatmentPaper industrySelected version:Basic type: JUMO tecLine PRO pH combination electrodeBasic type extension: Process electrodeActive part: HT glassDiaphragm: annular gap diaphragmElectrical connection to electrode: VP plug-in head Pg13.5Extra codes: Salt reserve, with integrated Pt1000Order code: 201020/79-12-10-18/837, 841
General descriptionThe electrodes are characterised by high mechanical and chemical resistance. Due to the stable PVDF body, there is practically no risk of the sensor breaking. The electrolyte of these combination electrodes guarantees a stable measured value, even in critical media containing sulphite.A Pt1000 temperature sensor is integrated. Depending on the application, the electrodes can be manufactured as pH or redox electrodes. An open annular gap diaphragm is used as the diaphragm.Areas of applicationChemical industryWaste water treatmentSewage treatmentPaper industrySelected version:Basic type: JUMO tecLine PRO pH combination electrodeBasic type extension: Process electrodeActive part: UW glassDiaphragm: annular gap diaphragmElectrical connection to electrode: screw head Pg13.5Extra codes: Salt reserveOrder code: 201020/79-18-10-22/837
General descriptionThe electrodes are characterised by high mechanical and chemical resistance. Due to the stable PVDF body, there is practically no risk of the sensor breaking. The electrolyte of these combination electrodes guarantees a stable measured value, even in critical media containing sulphite.A Pt1000 temperature sensor is integrated. Depending on the application, the electrodes can be manufactured as pH or redox electrodes. An open annular gap diaphragm is used as the diaphragm.Areas of applicationChemical industryWaste water treatmentSewage treatmentPaper industrySelected version:Basic type: JUMO tecLine PRO pH combination electrodeBasic type extension: Process electrodeActive part: UW glassDiaphragm: annular gap diaphragmElectrical connection to electrode: VP plug-in head Pg13.5Type supplements: Salt reserve, with integrated Pt1000Order code: 201020/79-18-10/837, 841
High-quality industrial electrodesProcess/industrial applicationswith gold tipdifferent insertion lengthsspecial types on requestSelected version:Basic type: JUMO tecLine redox combination electrode, glass shaftActive part: platinum capDiaphragm: 1x zirconium dioxideElectrical connection to electrode: screw head Pg13.5 (S8)Insertion length: 120mm (standard)Extra codes: Salt reserveOrder code: 201025/51-22-07-22-120/837
High-quality industrial electrodesProcess/industrial applicationswith gold tipdifferent insertion lengthsspecial types on requestSelected version:Basic type: JUMO tecLine redox combination electrode, glass shaftActive part: gold capDiaphragm: 1x zirconium dioxideElectrical connection to electrode: screw head Pg13.5 (S8)Insertion length: 120mm (standard)Extra codes: Salt reserveOrder code: 201025/51-32-07-22-120/837
Typical areas of applicationindustrial waste water technologyprocess measurements, electroplating, paper industry, beverage industryoily waste watersuspensions, lacquers, media with solid particlesDouble-chamber design in the presence of electrode poisonsFluoride-containing (hydrofluoric acid-containing) media up to 1000 mg/l HFSpecial featuresDirt-repellent PTFE ring diaphragm with highly viscous KCl solution (gel) or perforated or annular gap diaphragm with polymerised solid electrolyte - practically blockage-freeCartridge discharge system with silver ion-free reference electrolytePressure-resistant versions up to 10 bar (50 °C)Temperature range: see order detailsOptional temperature sensors can be integratedOptional salt reservoir to increase service life in media with low conductivitySelected version:Basic type: Glass shaftActive part: Platinum capDiaphragm: PTFE ringElectrical connection to electrode: screw head Pg13.5 (S8)Insertion length: 120mm (standard)Extra codes: Salt reserveOrder code: 201025/51-22-04-22-120/837
High-quality industrial electrodesProcess/industrial applicationswith gold tipdifferent insertion lengthsspecial types on requestSelected version:Basic type: JUMO tecLine redox combination electrode, PEI plastic with protective cageActive part: Platinum domeDiaphragm: 1x glass fiberElectrical connection to electrode: screw head Pg13.5 (S8)Fitting length: 120mm (standard)Extra codes: Salt reserve, double chamber KCI/KCIOrder code: 201025/72-22-05-22-120/837, 838