Electrodes and sensors are used in industry for a variety of applications to measure and monitor physical, chemical and biological processes.
The electrodes and sensors are generally used to measure and control certain parameters. They are used to increase efficiency and improve the quality of production processes and to ensure safety in the workplace.
Overall, electrodes and sensors help to make industrial processes more efficient, safer and of higher quality. They enable the measurement and control of important parameters in order to increase the effectiveness and profitability of production processes.
Some examples of applications are
- pH sensors and electrodes
- Oxygen sensors and electrodes
- Conductivity sensors and electrodes
- Temperature sensors and electrodes
- Biological sensors and electrodes
- Water Analyzers
- Liquid chemistry
- Controls
- Electrodes and sensors
- Hand-held measuring instruments and analysis cases
- Laboratory Benchtop Meters
- NeoTec World
- Permeate
- Clinical Solutions
- Seminars & Webinars
- Ozone and UV technology
- Dosing pumps
- Gas Measuring Instruments
- Hygiene and Disinfection
- Water Meters
- Accessories
- Blog
Filter products
General descriptionThe electrodes are characterised by high mechanical and chemical resistance. Due to the stable PVDF body, there is practically no risk of the sensor breaking. The electrolyte of these combination electrodes guarantees a stable measured value, even in critical media containing sulphite.A Pt1000 temperature sensor is integrated. Depending on the application, the electrodes can be manufactured as pH or redox electrodes. An open annular gap diaphragm is used as the diaphragm.Areas of applicationChemical industryWaste water treatmentSewage treatmentPaper industrySelected version:Basic type: JUMO tecLine PRO pH combination electrodeBasic type extension: Process electrodeActive part: HT glassDiaphragm: annular gap diaphragmElectrical connection to electrode: VP plug-in head Pg13.5Extra codes: Salt reserve, with integrated Pt1000Order code: 201020/79-12-10-18/837, 841
General descriptionThe electrodes are characterised by high mechanical and chemical resistance. Due to the stable PVDF body, there is practically no risk of the sensor breaking. The electrolyte of these combination electrodes guarantees a stable measured value, even in critical media containing sulphite.A Pt1000 temperature sensor is integrated. Depending on the application, the electrodes can be manufactured as pH or redox electrodes. An open annular gap diaphragm is used as the diaphragm.Areas of applicationChemical industryWaste water treatmentSewage treatmentPaper industrySelected version:Basic type: JUMO tecLine PRO pH combination electrodeBasic type extension: Process electrodeActive part: UW glassDiaphragm: annular gap diaphragmElectrical connection to electrode: screw head Pg13.5Extra codes: Salt reserveOrder code: 201020/79-18-10-22/837
General descriptionThe electrodes are characterised by high mechanical and chemical resistance. Due to the stable PVDF body, there is practically no risk of the sensor breaking. The electrolyte of these combination electrodes guarantees a stable measured value, even in critical media containing sulphite.A Pt1000 temperature sensor is integrated. Depending on the application, the electrodes can be manufactured as pH or redox electrodes. An open annular gap diaphragm is used as the diaphragm.Areas of applicationChemical industryWaste water treatmentSewage treatmentPaper industrySelected version:Basic type: JUMO tecLine PRO pH combination electrodeBasic type extension: Process electrodeActive part: UW glassDiaphragm: annular gap diaphragmElectrical connection to electrode: VP plug-in head Pg13.5Type supplements: Salt reserve, with integrated Pt1000Order code: 201020/79-18-10/837, 841
High-quality industrial electrodesProcess/industrial applicationswith gold tipdifferent insertion lengthsspecial types on requestSelected version:Basic type: JUMO tecLine redox combination electrode, glass shaftActive part: platinum capDiaphragm: 1x zirconium dioxideElectrical connection to electrode: screw head Pg13.5 (S8)Insertion length: 120mm (standard)Extra codes: Salt reserveOrder code: 201025/51-22-07-22-120/837
High-quality industrial electrodesProcess/industrial applicationswith gold tipdifferent insertion lengthsspecial types on requestSelected version:Basic type: JUMO tecLine redox combination electrode, glass shaftActive part: gold capDiaphragm: 1x zirconium dioxideElectrical connection to electrode: screw head Pg13.5 (S8)Insertion length: 120mm (standard)Extra codes: Salt reserveOrder code: 201025/51-32-07-22-120/837
Typical areas of applicationindustrial waste water technologyprocess measurements, electroplating, paper industry, beverage industryoily waste watersuspensions, lacquers, media with solid particlesDouble-chamber design in the presence of electrode poisonsFluoride-containing (hydrofluoric acid-containing) media up to 1000 mg/l HFSpecial featuresDirt-repellent PTFE ring diaphragm with highly viscous KCl solution (gel) or perforated or annular gap diaphragm with polymerised solid electrolyte - practically blockage-freeCartridge discharge system with silver ion-free reference electrolytePressure-resistant versions up to 10 bar (50 °C)Temperature range: see order detailsOptional temperature sensors can be integratedOptional salt reservoir to increase service life in media with low conductivitySelected version:Basic type: Glass shaftActive part: Platinum capDiaphragm: PTFE ringElectrical connection to electrode: screw head Pg13.5 (S8)Insertion length: 120mm (standard)Extra codes: Salt reserveOrder code: 201025/51-22-04-22-120/837
High-quality industrial electrodesProcess/industrial applicationswith gold tipdifferent insertion lengthsspecial types on requestSelected version:Basic type: JUMO tecLine redox combination electrode, PEI plastic with protective cageActive part: Platinum domeDiaphragm: 1x glass fiberElectrical connection to electrode: screw head Pg13.5 (S8)Fitting length: 120mm (standard)Extra codes: Salt reserve, double chamber KCI/KCIOrder code: 201025/72-22-05-22-120/837, 838
Room, outdoor and duct resistance thermometers Typ: 902520/21-573-1003-1/000 Measuring range from -30 to +90°C Measuring insert 1x temperature sensor Pt100 in two-wire circuit Transmitter: without Protection class IP65 Suitable for use in air conditioning technology Room, outdoor and duct resistance thermometers are designed for air conditioning technology and are mainly used for temperature measurement in rooms, air ducts and outdoors. Various plastic device versions with different degrees of protection are available for the respective measuring task. A Pt100 temperature sensor in accordance with DIN EN 60751 class B in a two-wire circuit is installed as standard, but variants with Pt500, Pt1000, Ni1000 and various NTC sensors are also possible. The connection terminals allow optional continuation in three- and four-wire circuits. An integrated measuring transducer can also be selected as an option.
Room, outdoor and duct resistance thermometers Typ: 902520/21-573-1005-1/000 Measuring range from -30 to +90°C Measuring insert 1x temperature sensor Pt1000 in two-wire circuit Transmitter: without Protection class IP65 Suitable for use in air conditioning technology Room, outdoor and duct resistance thermometers are designed for air conditioning technology and are mainly used for temperature measurement in rooms, air ducts and outdoors. Various plastic device versions with different degrees of protection are available for the respective measuring task. A Pt100 temperature sensor in accordance with DIN EN 60751 class B in a two-wire circuit is installed as standard, but variants with Pt500, Pt1000, Ni1000 and various NTC sensors are also possible. The connection terminals allow optional continuation in three- and four-wire circuits. An integrated measuring transducer can also be selected as an option.
Room, outdoor and duct resistance thermometers Typ: 902520/22-573-1003-1/000 Measuring range from -30 to +90°C Measuring insert 1x temperature sensor Pt100 in two-wire circuit Transmitter: without Protection class IP65 Suitable for use in air conditioning technology Room, outdoor and duct resistance thermometers are designed for air conditioning technology and are mainly used for temperature measurement in rooms, air ducts and outdoors. Various plastic device versions with different degrees of protection are available for the respective measuring task. A Pt100 temperature sensor in accordance with DIN EN 60751 class B in a two-wire circuit is installed as standard, but variants with Pt500, Pt1000, Ni1000 and various NTC sensors are also possible. The connection terminals allow optional continuation in three- and four-wire circuits. An integrated measuring transducer can also be selected as an option.
Room, outdoor and duct resistance thermometers Typ: 902520/22-573-1005-1/000 Measuring range from -30 to +90°C Measuring insert 1x temperature sensor Pt1000 in two-wire circuit Transmitter: without Protection class IP65 Suitable for use in air conditioning technology Room, outdoor and duct resistance thermometers are designed for air conditioning technology and are mainly used for temperature measurement in rooms, air ducts and outdoors. Various plastic device versions with different degrees of protection are available for the respective measuring task. A Pt100 temperature sensor in accordance with DIN EN 60751 class B in a two-wire circuit is installed as standard, but variants with Pt500, Pt1000, Ni1000 and various NTC sensors are also possible. The connection terminals allow optional continuation in three- and four-wire circuits. An integrated measuring transducer can also be selected as an option.
Room, outdoor and duct resistance thermometers Typ: 902520/22-474-1003-1/330,(-40..80°C) Measuring range from -40 to +80°C (Measuring range only in conjunction with transmitter) Measuring insert 1x temperature sensor Pt100 in two-wire circuit Transmitter: 1x analog transmitter, 4-20 mA output (only in conjunction with 1xPt100 tw)(-40 to +80°C) Protection class IP65 Suitable for use in air conditioning technology Room, outdoor and duct resistance thermometers are designed for air conditioning technology and are mainly used for temperature measurement in rooms, air ducts and outdoors. Various plastic device versions with different degrees of protection are available for the respective measuring task. A Pt100 temperature sensor in accordance with DIN EN 60751 class B in a two-wire circuit is installed as standard, but variants with Pt500, Pt1000, Ni1000 and various NTC sensors are also possible. The connection terminals allow optional continuation in three- and four-wire circuits. An integrated measuring transducer can also be selected as an option.
Room, outdoor and duct resistance thermometers Typ: 902520/23-573-1003-1/000 Measuring range from -30 to +90°C Measuring insert 1x temperature sensor Pt100 in two-wire circuit Transmitter: without Protection class IP65 Suitable for use in air conditioning technology Room, outdoor and duct resistance thermometers are designed for air conditioning technology and are mainly used for temperature measurement in rooms, air ducts and outdoors. Various plastic device versions with different degrees of protection are available for the respective measuring task. A Pt100 temperature sensor in accordance with DIN EN 60751 class B in a two-wire circuit is installed as standard, but variants with Pt500, Pt1000, Ni1000 and various NTC sensors are also possible. The connection terminals allow optional continuation in three- and four-wire circuits. An integrated measuring transducer can also be selected as an option.
Room, outdoor and duct resistance thermometers Typ: 902520/23-573-1005-1/000 Measuring range from -30 to +90°C Measuring insert 1x temperature sensor Pt1000 in two-wire circuit Transmitter: without Protection class IP65 Suitable for use in air conditioning technology Room, outdoor and duct resistance thermometers are designed for air conditioning technology and are mainly used for temperature measurement in rooms, air ducts and outdoors. Various plastic device versions with different degrees of protection are available for the respective measuring task. A Pt100 temperature sensor in accordance with DIN EN 60751 class B in a two-wire circuit is installed as standard, but variants with Pt500, Pt1000, Ni1000 and various NTC sensors are also possible. The connection terminals allow optional continuation in three- and four-wire circuits. An integrated measuring transducer can also be selected as an option.
Room, outdoor and duct resistance thermometers Typ: 902520/23-474-1003-1/330,(-30..60°C) Measuring range from -40 to +80°C Measuring insert 1x temperature sensor Pt100 in two-wire circuit Transmitter: 1x analog transmitter, output 4 to 20 mA (only in conjunction with 1x Pt100 zl) (-30 to 60°C) Protection class IP65 Suitable for use in air conditioning technology Room, outdoor and duct resistance thermometers are designed for air conditioning technology and are mainly used for temperature measurement in rooms, air ducts and outdoors. Various plastic device versions with different degrees of protection are available for the respective measuring task. A Pt100 temperature sensor in accordance with DIN EN 60751 class B in a two-wire circuit is installed as standard, but variants with Pt500, Pt1000, Ni1000 and various NTC sensors are also possible. The connection terminals allow optional continuation in three- and four-wire circuits. An integrated measuring transducer can also be selected as an option.
Room, outdoor and duct resistance thermometers Typ: 902520/23-474-1003-1/333,(-30..60°C) Measuring range from -40 to +80°C (Measuring range only in conjunction with transmitter) Measuring insert 1x temperature sensor Pt100 in two-wire circuit Transmitter: 1x analog transmitter, output 0 to 10V (only in conjunction with 1x Pt100 zl)(-30 to +60°C) Protection class IP65 Suitable for use in air conditioning technology Room, outdoor and duct resistance thermometers are designed for air conditioning technology and are mainly used for temperature measurement in rooms, air ducts and outdoors. Various plastic device versions with different degrees of protection are available for the respective measuring task. A Pt100 temperature sensor in accordance with DIN EN 60751 class B in a two-wire circuit is installed as standard, but variants with Pt500, Pt1000, Ni1000 and various NTC sensors are also possible. The connection terminals allow optional continuation in three- and four-wire circuits. An integrated measuring transducer can also be selected as an option.
Room, outdoor and duct resistance thermometers Typ: 902520/23-474-1003-1/330,(-40..80°C) Measuring range from -40 to +80°C (Measuring range only in conjunction with transmitter) Measuring insert 1x temperature sensor Pt100 in two-wire circuit Transmitter: 1x analog transmitter, output 4 to 20 mA (only in conjunction with 1x Pt100 tw) (-40 to +80°C) Protection class IP65 Suitable for use in air conditioning technology Room, outdoor and duct resistance thermometers are designed for air conditioning technology and are mainly used for temperature measurement in rooms, air ducts and outdoors. Various plastic device versions with different degrees of protection are available for the respective measuring task. A Pt100 temperature sensor in accordance with DIN EN 60751 class B in a two-wire circuit is installed as standard, but variants with Pt500, Pt1000, Ni1000 and various NTC sensors are also possible. The connection terminals allow optional continuation in three- and four-wire circuits. An integrated measuring transducer can also be selected as an option.
Room, outdoor and duct resistance thermometers Measuring range from -40 to +80°C (Measuring range only in conjunction with transmitter) Measuring insert 1x temperature sensor Pt100 in two-wire circuit Transmitter: 1x analog transmitter, output 0 to 10V (only in conjunction with 1x Pt100 tw) (-40 to +80°C) Protection class IP65 Suitable for use in air conditioning technology Room, outdoor and duct resistance thermometers are designed for air conditioning technology and are mainly used for temperature measurement in rooms, air ducts and outdoors. Various plastic device versions with different degrees of protection are available for the respective measuring task. A Pt100 temperature sensor in accordance with DIN EN 60751 class B in a two-wire circuit is installed as standard, but variants with Pt500, Pt1000, Ni1000 and various NTC sensors are also possible. The connection terminals allow optional continuation in three- and four-wire circuits. An integrated measuring transducer can also be selected as an option.
Our Neomeris conductivity cell with 12mm connection is used for the determination of the electrical conductivity in aqueous solutions. Inside the T-piece is the two-electrode measuring cell without temperature compensation. The installation is easy and fast due to the John Guest connectors. We recommend the use of the product in the fields of distillate, condensate, ultrapure water as well as fully demineralized water. Technical data Material Housing: POM T-piece John Guest ½" Material electrodes: V4A 4571 Cell constant: C = 0.1 +-5% Max. operating pressure: 6 bar Max. operating temperature: 60°C Electrical connection: - brown electrode, outer sheath - white Electrode, inside - blue: shieldCable length: 2.5 meters
Connection cable for pH/redox Length: 3 metres Cable type: pH and redox connection cable Ø 5 mm, 75 °C Connection end 1 (sensor side): rotatable cable socket Connection end 2 (device side): without Electronic sensors for analysing liquids require special connection cables and plug connectors. The following applies in principle: The connection between an electrochemical sensor and the transmitter/indicator/controller should be as short as possible. Normally, the cable length is 5 to 10 metres to ensure a high level of functional reliability. If longer cable lengths are required in exceptional cases, the technical documentation for the sensors and measuring devices should be consulted. The cable between the sensor and the analyser must be laid directly, without interruptions such as terminal strips or cable extensions. pH and redox measurement Special coaxial cables with a special design are used for pH and redox measurement. During these measurements, the sensor generates low-intensity DC voltages which are transmitted to the analyser. Due to the sometimes very high internal resistance (potentiostatic measuring principle with internal resistances of up to several gigaohms), these measurements are extremely sensitive to electrical interference and the effects of radiation. Under unfavourable conditions, even minimal movements of the cable can lead to measurement value distortions. An additional insulation layer of the JUMO coaxial cable increases the insulation resistance, which enables a secure connection of the sensor to the transmitter. Conventional coaxial cables from the antenna and computer sector are not suitable for this application and can damage the sensors. This can lead to immediate failure of the sensor as well as a shortened service life. For multiple sensors, for example with integrated temperature sensors, coaxial cables with single wires are available, such as the Variopin (VP).
Connection cable for pH/redox Length: 3 metres Cable type: pH and redox connection cable Ø 5 mm, 75 °C Connection end 1 (sensor side): rotatable cable socket Connection end 2 (device side): without Electronic sensors for analysing liquids require special connection cables and plug connectors. The following applies in principle: The connection between an electrochemical sensor and the transmitter/indicator/controller should be as short as possible. Normally, the cable length is 5 to 10 metres to ensure a high level of functional reliability. If longer cable lengths are required in exceptional cases, the technical documentation for the sensors and measuring devices should be consulted. The cable between the sensor and the analyser must be laid directly, without interruptions such as terminal strips or cable extensions. pH and redox measurement Special coaxial cables with a special design are used for pH and redox measurement. During these measurements, the sensor generates low-intensity DC voltages which are transmitted to the analyser. Due to the sometimes very high internal resistance (potentiostatic measuring principle with internal resistances of up to several gigaohms), these measurements are extremely sensitive to electrical interference and the effects of radiation. Under unfavourable conditions, even minimal movements of the cable can lead to measurement value distortions. An additional insulation layer of the JUMO coaxial cable increases the insulation resistance, which enables a secure connection of the sensor to the transmitter. Conventional coaxial cables from the antenna and computer sector are not suitable for this application and can damage the sensors. This can lead to immediate failure of the sensor as well as a shortened service life. For multiple sensors, for example with integrated temperature sensors, coaxial cables with single wires are available, such as the Variopin (VP).
Capacity measurement ion exchanger cartridgeOur Neomeris N-FLASH10 conductivity meter in a T-piece with 3/8 inch connection is a conductivity measuring instrument that is used to monitor the electrical conductivity of water after flowing through the ion exchanger cartridge. The measuring instrument including the integrated measuring cell is battery operated and permanently installed in the T-piece. If the measured electrical conductivity is below the limit value of 10µS/cm, the green LED flashes; if it is above, the red LED flashes, indicating that a cartridge or resin change is required. Due to the T-piece used, the measuring device can also be integrated very easily and is optimally installed in the liquid flow for a stable measurement. Measuring principle: The measuring cell generates an electrical signal that is proportional to the conductivity of the liquid. This signal is processed in the device and the LED is controlled via the programming stored in the device. Application: Conductivity meters are often used in water treatment plants in the process industry.Technical data:Screw-in thread: 3/8"; others available upon requestMaterial housing: POM black Material lid: Plexiglas Material electrodes: V4A 4571 Material O-ring: EPDM Cell constant: C= 0.6 +/- 10% Max. Operating pressure: 6 bar Max. Operating temperature: 60°C Temperature sensor: without Display: LED green <10μS/cm LED red >10μS/cm
Technical data: Screw-in thread: 1/4"; 1/2"; 3/4"; others available upon requestMaterial housing: POM black Material lid: Plexiglas Material electrodes: V4A 4571 Material O-ring: EPDM Cell constant: C= 0.6 +/- 10% Max. Operating pressure: 6 bar Max. Operating temperature: 60°C Temperature sensor: without Display: LED green <10μS/cm LED red >10μS/cm
Technical data: Screw-in thread: 1/4"; 1/2"; 3/4"; others available upon requestMaterial housing: POM black Material lid: Plexiglas Material electrodes: V4A 4571 Material O-ring: EPDM Cell constant: C= 0.6 +/- 10% Max. Operating pressure: 6 bar Max. Operating temperature: 60°C Temperature sensor: without Display: LED green <10μS/cm LED red >10μS/cm