Testomat® Limit TH – Precise water hardness monitoring for maximum process reliability

Our new Testomat Limit TH is a limit value measuring device that automatically monitors the residual total hardness (water hardness) in water. It is your reliable online analysis device for automatically monitoring the residual total hardness in water in the range from 0.05 to 25.0 °dH. You can continue to use all hardness indicators from the proven Testomat® 2000 series. With its intuitive touchscreen operation and clear menu navigation, it is easy to use and quick to set up. The device is ideal for water treatment in osmosis systems, softening systems, electroplating, commercial kitchens, laundries and industrial processes. The Testomat® Limit TH offers 72-hour operation without constant supervision and automatically informs you of the indicator level for uninterrupted measurements. With a short analysis time of only 2 minutes and flexible settings for limit values and measurement intervals, it ensures maximum efficiency. Integrated logging of limit violations and alarm messages creates transparency and security for your processes. For precise results, we recommend using original Heyl indicators and spare parts – for trouble-free operation and full warranty coverage. Order online now and benefit from a 3% discount in the HeylNeomeris shop. When you purchase a Testomat Limit device, you will also receive a hardness indicator of your choice free of charge. Secure the future of water hardness monitoring with the new Testomat® Limit TH – reliable, convenient and future-oriented.

Testomat Limit TH

Online analysis device for water hardness

The Testomat Limit TH is your reliable limit value measuring device for automatic monitoring of the residual total hardness (water hardness) in water. It is a compact analyser for online measurement of water hardness based on the principle of ‘limit value monitoring with colour change’ in the measuring range 0.05 – 25.0 °dH. Our customers appreciate the ease of use of the new device. It is easy to operate thanks to its touchscreen and drop-down menu.

Areas of application:

The Testomat Limit TH was designed for use in water treatment (e.g. osmosis systems, electroplating, large boiler systems, laundries, commercial kitchens, water softening systems). The device is a limit value measuring device that automatically monitors the residual total hardness (water hardness) in the water.

The result of the analysis is displayed in colour in the ‘Measured values’ menu. Below limit value = green frame, above limit value = double red frame.

Limit value: You can set the desired limit value to be monitored yourself. The adjustable limit value range depends on the indicator type. Indicators with different measuring ranges are available for use with Testomat Limit TH devices, depending on your operational requirements. The limit value to be monitored can be freely set within the measuring ranges of the indicator. All indicator types are available in two container sizes (100 ml and 500 ml). A detailed list of the individual suitable indicators with the corresponding item numbers can be found below.

Product advantages:

Self-test and continuous self-monitoring: The device status is displayed. The Testomat Limit TH performs a self-test when switched on and continuously monitors itself.

72 hours of operation without constant supervision. The Testomat Limit TH automatically indicates whether there is enough indicator available for continuous measurement. The device calculates whether the remaining indicator is sufficient for the next 72 hours of operation, taking into account the remaining indicator, the set interval pause and the amount of indicator consumed per measurement. 

Automatic display of the indicator level

Logging of limit value underruns and overruns with date and time.

Logging of alarm or error messages with date.

Flexible setting of limit values and measurement intervals

Free choice of hardness units in °dH, °f, ppm CaCo3 or mmol/l.

Short analysis time: approx. 2 minutes

Short measurement time: approx. 4 minutes per analysis

Technical highlights:

  • Adjustable limit value range: Limit values for residual hardness from 0.05 to 25.0 °dH can be determined by selecting the indicator
  • Interval operation: 0 to 60 minutes, plus manual start or external control
  • Long operating times thanks to 500 ml indicator supply (>1000 measurements)
  • SD card for measurement data logging and firmware updates
  • 4–20 mA interface for transmission of measured values
  • Optional retrofittable pump (40692) for automatic cleaning of the measuring chamber

Why use original Heyl indicators and spare parts?

For trouble-free operation and precise measurement results, use only original Heyl indicators and original Heyl spare parts. Third-party indicators and spare parts can lead to measurement errors and damage. Using other indicators or spare parts will void the warranty on the device!

Certificates & Approvals:

Conformity:

CE

EN 61326-1 Electrical equipment for measurement, control and laboratory use. EMC requirements

EN 61010-1 Safety requirements for electrical equipment for measurement, control and laboratory use

UK

CA

BS EN IEC 61326-1 Electrical equipment for measurement, control and laboratory use. EMC requirements General requirements

BS EN 61010-1+A1 Safety requirements for electrically operated measuring, control and laboratory equipment

Protection class: IP 44

Important information

  • Regular maintenance (every six months to annually) is required to ensure that the device functions properly.
  • Operate only with the specified DC voltage.

Order now and monitor water hardness reliably!

Get a 3% discount in our online shop

When you purchase a Testomat Limit device, you will also receive a free hardness indicator of your choice.

Do you have any questions about the product?

We are also happy to answer your questions by telephone.

Download:

Bedienungsanleitung

User manual

Mode de emploi

Gebruiksaanwijzing

Testomat Limit Flyer

Dimensions

Height 31,4 cm
Length 13,8 cm
Width 26,4 cm

Weight

Weight 5,6 kg

Other attributes

Country of origin EU
Customs tariff number 90278017
Technical data
Technical Data
property value
Power supply 24V DC current

Device protection 24 V: T0,8 A
Power consumption max. 16 VA, without external load
Protection class II
Protection type IP 44
Conformity EN 61326-1, EN 61010-1
BS EN IEC 61326-1, BS EN 61010-1+A1
Ambient temperature 10 – 40 °C
Measuring range Residual hardness in the range of 0,05 – 25,0 °dH . See Chapter 3.1 Available reagents
Contact load relay 28VDC/300W or 45VAC/300W ohm resistive load
Current interface Output of defined values (5, 8, 11, 14, 17, 20 mA) for displaying status and error messages, max. load 500 Ohms
Serial interface RS232 9600 Baud, 8 Bit, 1 stop bit, no parity
SD card Format FAT or FAT32 , max. 32GByte
Dimensions W x H x D = 424 x 323 x 138 mm
Weight 4500 g
Other The device is protected against reverse polarity.
Water connection
property value
Working pressure* 1 - 8 bar / 1 x 105 to 8 x 105 Pa *
Water intake Opaque pressure hose with external diameter 6/4x1 mm
Water drain Hose with internal diameter 12 mm
Water temperature 10 – 40 °C
*Under 1 bar pressure, a flow rate of 400 ml/min must be achieved for safe operation!
Skip product gallery

We recommend our indicators

Testomat® indicator TH 2005, 500ml
Product number: 152005
Testomat Indicator TH2005 – Residual Hardness Measurement Original indicator for precise determination of residual hardness in water The Testomat Indicator TH2005 from Heyl, 500 ml, is an original measurement solution for determining residual hardness in water. The indicator ensures high measurement accuracy and reliability for daily use. Measurements are provided in standardized units (°dH, °f, ppm CaCO₃, and mmol/l). Order online now and benefit from a 3% discount in the online shop on Heyl products. The indicator is specifically designed for residual hardness monitoring in water treatment. It is suitable for continuous process control and stable water quality. Advantages of the Original Testomat TH2005 Indicator The Testomat Indicator TH2005 offers a wide range of benefits for reliable residual hardness monitoring in demanding applications: High accuracy in the low range: Specifically designed for precise determination of very low residual hardness from 0.05 to 0.50 °dH. Reliable color reaction: Clear and reproducible color changes allow secure monitoring of residual hardness. Versatile display units: Measurement in °dH, °f, ppm CaCO₃, and mmol/l – ideal for international and industrial applications. Optimal device compatibility: Precisely calibrated for the Testomat 2000 series, the new Testomat Limit from Heyl, and other compatible Testomat devices. Suitable for continuous operation: Designed for ongoing process control in water treatment, industry, and supply technology. Heyl original quality: Ensures proper device operation and retention of warranty and guarantee claims. Where can the TH2005 indicator be used? It is suitable for water treatment, industry, and supply technology. Compatible with the following devices: Testomat 2000 Testomat 2000 CAL Testomat 2000 DUO Testomat 2000 V Testomat 2000 self clean Testomat ECO Testomat ECO-PLUS Testomat EVO TH Testomat Limit Which measurement ranges does the TH2005 indicator cover? 0.05–0.50 °dH with 0.01 resolution 0.09–0.89 °f 0.89–8.93 ppm CaCO₃ 0.01–0.09 mmol/l

€104.20*
Testomat® indicator TH 2005 2x100ml
Product number: 151005
Testomat® Indicator TH2005 from Heyl – Precise Low-Range Residual Hardness Measurement 2x100 ml Residual hardness 0.05–0.50 °dH for Testomat 2000 2x100 ml Testomat Indicator TH2005, 2x100 ml bottles, for measuring residual hardness. The original bottles allow direct use without transferring the solution. The Testomat® Indicator TH2005 is an original indicator solution for reliable measurement and threshold monitoring of residual hardness in the range of 0.05 to 0.50 °dH. Supplied in two practical 100-ml original bottles, the indicator enables direct application without transferring. The indicator is particularly suitable for applications with high water quality requirements, where precise monitoring of low hardness ranges is essential. Which devices is the TH2005 indicator from Heyl compatible with? The TH2005 indicator is compatible with the following measuring devices: Testomat 2000® Testomat 2000® CAL Testomat 2000® DUO Testomat 2000® V Testomat 2000® self clean Testomat ECO® Testomat ECO®-Plus Testomat® EVO TH Testomat® Limit Which values does the original TH2005 indicator from Heyl measure? The Testomat® Indicator TH2005 covers multiple units and offers high resolution: 0.05–0.50 °dH (Resolution 0.01) 0.09–0.89 °f (Resolution 0.02) 0.89–8.93 ppm CaCO₃ (Resolution 0.2) 0.01–0.09 mmol/l (Resolution 0.01) Using the original indicator ensures high measurement accuracy, proper device operation, and retention of warranty and guarantee claims.

€88.80*
Testomat® indicator TH 2025 500ml
Product number: 152025
500 ml bottle original Testomat® indicator TH for limit value: 0,25- 2,50°dH for measuring residual hardness.  °dH (resolution): 0,25- 2,50 (0,05) °f (resolution): 0,45-4,48 (0,10) ppm CaCO3 (resolution): 4,48-44,8 (0,9) mmol/l (resolution): 0,04-0,45 (0,01)

€104.20*
Testomat® indicator TH 2025 2x100ml
Product number: 151025
2x100 ml bottles original Testomat® indicator TH 2025 for limit value: 0,25- 2,50°dH for measuring residual hardness.  °dH (resolution): 0,25- 2,50 (0,05) °f (resolution): 0,45-4,48 (0,10) ppm CaCO3 (resolution): 4,48-44,8 (0,9) mmol/l (resolution): 0,04-0,45 (0,01)

€88.80*
Testomat® indicator TH2050 500ml
Product number: 152050
The 500 ml bottle of original Testomat® indicator TH 2050 for the limit value 0.5 - 5.0 °dH only for Testomat® EVO TH and Testomat® LAB TH.

€107.70*
Testomat® indicator TH2050 2x100ml
Product number: 151050
The 100 ml bottle of original Testomat® indicator TH 2050 for the limit value 0.5- 5,0°dH only for Testomat® EVO TH. One packing unit contains 2 bottles á 100ml.

€88.80*
Testomat® indicator TH 2100 500ml.
Product number: 152100
500 ml bottle original Testomat® indicator TH 2100 for limit value: 1,00-10,00°dH for measuring residual hardness. °dH (resolution): 1,00-10,00 (0,20) °f (resolution): 1,79-17,9 (0,40) ppm CaCO3 (resolution): 17,9-179 (3,8) mmol/l (resolution): 0,18 -1,79 (0,04)

€107.70*
Testomat® indicator TH 2100 2x100ml
Product number: 151100
2x100 ml bottles original Testomat® indicator TH 2100 for limit value:1,00-10,00°dH°dH for measuring residual hardness. °dH (resolution): 1,00-10,00 (0,20) °f (resolution): 1,79-17,9 (0,40) ppm CaCO3 (resolution): 17,9-179 (3,8) mmol/l (resolution): 0,18 -1,79 (0,04)

€88.80*
Testomat® indicator TH 2250 500ml.
Product number: 152250
500 ml bottle original Testomat® indicator TH 2250 for limit value: 2,50-25,00°dH for measuring residual hardness.   °dH (resolution): 2,50-25,00 (0,50) °f (resolution): 4,48-44,8 (0,40) ppm CaCO3 (resolution): 44,8-448 (3,8) mmol/l (resolution): 0,45 -4,48 (0,04)

€107.70*
Testomat® indicator TH 2250 2x100ml
Product number: 151250
2x100 ml bottles original Testomat® indicator TH 2250 for limit value: 2,50-25,00°dH for measuring residual hardness.    limit value: °dH (resolution): 2,50-25,00 (0,50) °f (resolution): 4,48-44,8 (0,40) ppm CaCO3 (resolution): 44,8-448 (3,8) mmol/l (resolution): 0,45 -4,48 (0,04)

€88.70*
Skip product gallery

Recommended accessories

Testomat® Limit TH maintenance kit for Testomat® LIMIT
Product number: 270339
HeylNeomeris offers you the right maintenance set for your Testomat Limit, with all the components you need for smooth and efficient upkeep. The set consists of: 2 x O-Ring 3x1 EPDM 70, black for Testomat LIMIT  order code: 33764 1 x O-Ring 18x2 EPDM order code: 33776 2 x O-Ring 1,78x1,78  order code: 11245 1 x Sight glass for Testomat LIMIT  order code: 37517 1 x Sight glass with Nut for Testomat LIMIT  order code: 40675 1 x Magnetic stirrer order code: 40050 1 x Inlet hose 1/4 for Testomat LIMIT  order code: 40683 1 x Drain hose 1/4 PE for Testomat LIMIT  order code: 40684 1 x Filter sieve for inlet 19.5dx25 (260µ mesh size)  order code: 11217 1 x Flow regulator core  order code: 11225 1 x Cleaning brush set  Order code: 32287

€332.40*
Annual service kit Testomat® Limit TH
Product number: 270359
The annual service set for your Testomat Limit is perfectly designed to ensure that you always have all the regularly replaceable components at hand. For reliable and regular maintenance. The set consists of: 1 x Flat seal 24x2 EPDM code number: 33777 1 x Sight glass with groove  code number: 40675 1 x Mirror disc for Testomat LIMIT  code number: 37517 1 x O-ring 18x2  code number: 33776 1 x Magnetic stirrer for measurement chamber recording  code number: 40050

€291.60*
Retrofit kit for Selfclean function for Testomat LIMIT
Product number: 40681
The Selfclean function from Heyl allows cleaning cycles to be carried out independently through an additional dosing pump. Through continuous cleaning, it is ensured that the measurement results are not distorted. In addition, maintenance effort is reduced and the lifespan of your Testomat LIMIT is extended. Delivery includes The expansion kit (item no. 40681) for installing a second pump for the cleaning function consists of the following components: 1) Pump with motor (fully pre-assembled) 2) 1 beak valve (item no. 33805) at the outlet) 3) 1 large O-ring ø 11 x 1 (item no. 33716) 4) 1 small O-ring ø 1.78 x 1,78 (item no. 11245) 5) 1 casing (item no. 33752) 6) 1 beak valve (item no.. 33805) at the inlet 7) 2 screws (item no. 33028) for attaching the pump (already provided) 8) 1 tube 250 mm (item no. 40433) Suction side to the bottle with cleaning fluid 9) 1 tube 250 mm (item no. 40433) Pressure side to the measuring chamber 10) 2 screws (item no. 33028) for attachment to the control unit (already provided) Download Einbauanleitung_Testomat Limit_SelfClean-Pumpe Installation instructions_Testomat Limit_SelfClean pump Instructions de installation_Pompe Testomat Limit_SelfClean Installatiehandleiding_Testomat Limit_SelfClean-pomp

€375.50*
Testomat 2000® Self clean cleaning reagent
Product number: 151105
Cleaning reagent in 500ml-bottle for Testomat 2000® Self clean Testomat 2000® self clean is a special version of Testomat 2000® with an additional dosing pump for cleaning or disinfecting agents after an analysis. It can be used to remove possible pollution of the measuring chamber and the drain hose. After a preset number of analysis cycles, the measuring chamber is rinsed and the agent is added to the water in the measuring chamber. After a reaction time of 30 seconds, the content of the measuring chamber is dumped. The measuring chamber is subsequently rinsed twice.    

€83.20*
Connection Set for Testomat 2000® / ECO / EVO / LAB / Limit
Product number: 40187
In diesem Anschluss-Set ist alles enthalten, was Sie für den schnellen Anschluss des Testomat 2000®- oder Titromat®-Gerätes benötigen.   Inhalt: 5 m Kunststoffrohr PE 6/4x1,blau 2 m Ablaufschlauch di = 12 mm 1 Kugelhahn, PPSV 011223W 1 Reduzier-Verbinder 10 auf 6 mm 1 Reduziernippel 3/8"-1/2"

€151.50*
Pressure regulator - selfassembly kit
Product number: 880505
The pressure regulator is suitable for all Testomat® devices. It is used for pressures from 0.5 to 10 bar in order to avoid any pressure fluctuations that may occur and to ensure an optimum operating pressure. Kit consisting of: Pressure gauge, rear connection Bracket with nut 2 x straight screw-in fittings 1/4 ‘ x 6 mm  Technical data: max. inlet pressure: 25 bar Ambient temperature: 0-50 °C Pressure gauge connection G 1/4 Weight: 200 g  City water: approved Soft water: approved Demineralised water: not approved Condensate: not authorised

€173.76*