Spare Parts – Reliable Supply for Your Measurement and Control Devices
For long-term and trouble-free operation of your measurement and control devices, HeylNeomeris offers a comprehensive range of high-quality spare parts. Whether sensors, seals, electronic modules, or mechanical components – you’ll find the right parts for quick and easy repairs.
Examples from our range: drain connections, drain funnels, connection sets, sealing kits, and dosing pumps.
- Water Analyzers
- Liquid chemistry
- Controls
- Electrodes and sensors
- Hand-held measuring instruments and analysis cases
- Laboratory Benchtop Meters
- NeoTec World
- Permeate
- Clinical Solutions
- Seminars & Webinars
- Ozone and UV technology
- Dosing pumps
- Gas Measuring Instruments
- Hygiene and Disinfection
- Water Meters
- Accessories
- Blog
Filter products
The flow regulator DN 80, 3" is suitable for the NEOMERIS Softmaster RS.
FLOWClip® dosing pump for Testomat® 2000 self clean and Testomat® 2000 CLT self clean.Reliable diaphragm pump for automatic dosing of cleaning agents into the measuring chamber – for more thorough cleaning and stable measuring quality. Delivery rate: 0.1 l/min · self-priming up to 3 mWS · mounting: 35 mm DIN top-hat rail. Buy FLOWClip dosing pump from Heyl online Automatic cleaning of the measuring chamber The FLOWClip® dosing pump was specially developed for our Testomat® 2000 self clean and Testomat® 2000 CLT self clean devices to automatically fill the measuring chamber system with cleaning solution. Compared to rinsing with normal water, the measuring chamber is cleaned more thoroughly, deposits are reduced and process reliability is increased. The pump delivers a consistent flow thanks to its precise diaphragm technology and automatically fills the device's measuring chamber system with cleaning solution, thereby cleaning the measuring chamber. Why buy the original FLOWClip dosing pump for your Testomat 2000 self clean? Ready for immediate use upon delivery – minimal downtime Easy to mount on a 35 mm DIN top-hat rail Low-maintenance design – low operating costs and high availability Compatible with Testomat® 2000 self clean and Testomat® 2000 CLT self clean – easy integration into existing installations Areas of application Automatic dosing of cleaning agents into the measuring chamber of the Testomat® 2000 self clean / Testomat® 2000 CLT self clean Optimisation of measuring chamber hygiene Your advantages at a glance Constant dosing performance: 0.1 l/min for controlled, reproducible results Self-priming: up to 3 mWS Stable process conditions: Automatic cleaning of the measuring chamber for reliable measured values Quick installation: Mounting on a 35 mm DIN top-hat rail reduces installation effort Range of applications: Suitable for cleaning agents (item number: 151105 / Testomat® Self Clean cleaning solution 500 ml) Low maintenance: For long running times and low service intervals Important installation information The pump is ready for operation upon delivery Observe the technical data and keep the suction line as short as possible (optimised suction behaviour) Check connections for leaks and extend flushing times if necessary Can be used in Testomat devices of the 2000 and TITROMAT series The pump is generally low-maintenance – ideal for continuous system operation Maintenance & service Check the following at regular intervals: Tightness of hose connections, screw connections, etc. Contamination of hose lines (clean or replace if necessary). Tip: A preventive check as part of regular system maintenance increases operational safety and extends the service life of the components. Why should I buy the FLOWClip® dosing pump? Original spare part from Heyl Greater process stability: Clean measuring chambers deliver reliable measurements – reducing false alarms and rework Less downtime: Plug and play, quick installation, low maintenance Predictable costs: Durable diaphragm technology, reduced service calls Order the FLOWClip® dosing pump now Automate measuring chamber cleaning – for stable measurements, higher system availability and less maintenance. Secure a 3% online shop discount on all Heyl items. Frequently Asked Questions Is the dosing pump ready for use immediately after delivery? Yes. The FLOWClip® is delivered ready for operation. Simply connect it, keep the suction line as short as possible, and check all connections for leaks. How can I ensure reliable suction? Ensure reliable suction by keeping the suction line as short as possible and checking all hose connections for leaks. How much maintenance is required? The pump is low-maintenance. We recommend regularly checking hose connections and lines for leaks or contamination.
The fuse T0,16 A is a spare part for Testomat 2000® / ECO® and Titromat®.
The fuse T1,0 A is a spare part for Testomat 2000® / ECO® and Titromat®.
Gasket kit T2000 (according to maintenance complexity) TESTOMAT®2000 Spare part requirements for 2-3 years of operation gasket kit T2000 (according to maintenance complexity) Gasket kit T2000 (according to maintenance complexity) contains: 4 x flat gasket 24x2 EPDM 70 1 x O-Ring 18x2 EPDM 1 x O-Ring 4,47 x 1,78 1 x O-Ring 20x2 2 x O-Ring 10,82 x 1,78
The motor and pump head have to change after 120 operating hours.You reach this at a analysis interval of 30 minutes after aprox. 2 years.It means, the motor have a service life of under one year at a interval of 10 minutes.You can't change the pump head only, as the charcoal pencil is worn.
Holder for sight glass windows of the measuring chamber in Testomat ECO®, EVO TH and TITROMAT.
Testomat® 808 spare part: Hose adapter 2.4mm
Testomat® 808 SiO2 / Testomat® LAB CL / Testomat 2000® PO4 / Testomat 2000® Polymer - Spare part: Hose adapter 3.5mm
Spare part bottle connection/suction device: Insert for the screw cap with suction tube for 500ml Testomat 2000® / Testomat ECO® / Testomat / Titromat indicator bottles.
LED holder Testomat® 808 SiO2, complete
Magnet valve, 2/2-ways for Testomat ECO®
Magnetic stirring core for chamber holder of Testomat® and TESTOMAT®808.
"Professional" Maintenance Kit for Testomat® 2000 & ECO Professional Maintenance Set in a Case for Your Testomat Water Analysis Devices from Heyl The "Professional" maintenance kit contains a comprehensive selection of spare and wear parts specifically for the Testomat® 2000 and Testomat® ECO series. The kit is ideal for regular maintenance or repairs on your devices. What Does the Professional Maintenance Kit Include? 6x 011210 Plugs for Measuring Chamber 4x 011216 O-Ring 20x2 2x 011217 Inlet Filter 19.5dx25 2x 011218 Spring for Inlet 2x 011225 Complete Flow Regulator Core 4x 011249 O-Ring 10.82 x 1.78 2x 031582 Fuse G-, 5x20mm, M4A 2x 031584 Solder-in Fuse, TR5, T0.2A 2x 031585 Solder-in Fuse, TR5, T0.315A 2x 031592 Solder-in Fuse, TR5, T1.0A 2x 031595 Solder-in Fuse, TR5, T0.1A 2x 031596 Solder-in Fuse, TR5, T0.08A 2x 031622 Solder-in Fuse, TR5, T0.16A 1x 032287 Cleaning Brush Set 2x 033253 Screw M3x40, A2, DIN 965 2x 033775 O-Ring 4.47 x 1.78 2x 033776 O-Ring 18x2 EPDM 4x 033777 Flat Gasket 24x2 EPDM 70 2x 040011 Suction Hose, complete 2x 040016 Pressure Hose, complete 2x 040040 Valve Set 2x 040050 Magnetic Stirring Core 1x 040121 Inlet Connection 3x 040131 Screw Cap with T2000 Insert 2x 040141 Pipe, PE, D=6 d=4x105 2x 040142 Pipe, PE, D=6 d=4x115 1x 040153 Screw-in Connector G 1/4 -6 2x 040154 Plug-In Elbow Connector 6-6 1x 040157 Elbow Screw Connector 4x 040170 Sight Glass 30x3 2x 040240 Pipe, PE, D=10 d=8x98 Professional Maintenance Set for Testomat Water Analysis Devices from Heyl The "Professional" maintenance kit was specially developed for the Testomat® 2000 and Testomat® ECO series and provides a comprehensive selection of spare and wear parts for professional service use. It is ideal for regular maintenance, servicing, and repairs of water analysis devices in industrial and commercial applications. With its clearly organized contents, the kit allows service work to be carried out quickly on-site, reducing downtime, efficiently maintaining maintenance intervals, and ensuring long-term measurement accuracy and operational reliability. For service technicians, maintenance staff, and operators, the kit is a practical all-in-one solution for daily operations. Advantages of the "Professional" Maintenance Kit for Testomat® 2000 & ECO The "Professional" maintenance kit offers a complete, practical set of components for servicing Testomat® 2000 and Testomat® ECO devices. All included spare and wear parts are precisely tailored to the requirements of these device series, enabling quick, professional maintenance without additional spare part procurement. By providing key components such as seals, fuses, hoses, valves, and cleaning accessories in a single kit, downtime is significantly reduced. At the same time, the kit supports economical maintenance by enabling preventive service and avoiding unplanned repairs.
Spare part measuring chamber holder without solenoid valve for Testomat 2000® and Titromat® Suitable for the following device types: Testomat 2000® Antox Testomat 2000® CN DUO Testomat 2000® DUO Testomat 2000® self-clean Testomat 2000® Titromat® M1 Titromat® M2 Titromat®KH Titromat®TH
Spare part for measuring chamber of T2000/ECO/808: Measuring Chamber Sight glass windows 30×3 with gasket
Measuring chamber, complete (0.3 - 1 bar) for TESTOMAT®808
The measuring chamber with double glazin, complete, is a spare part for Testomat® and TESTOMAT®ECO.