Heyl Neomeris Clinical Solutions – DI Water Systems for Safe Reprocessing in Medical Facilities
DI water as the foundation for safe reprocessing processes
A system for producing demineralized water (DI water) used as process water in medical reprocessing consists of several coordinated components. Modern water treatment systems ensure a reliable supply of high-quality process water for the reprocessing of medical devices in hospitals, sterile services departments (CSSD), outpatient practices and medical care centers (MVZ).
Professional guidelines increasingly recommend stricter limit values for water quality. Many hospital management teams and CSSD managers are already adapting their process water production to these new requirements. This not only increases legal security but also offers economic advantages by reducing damage to medical instruments, washer-disinfectors (WD) and sterilizers.
Limescale deposits, corrosion or silicate residues – common indicators of poor process water quality – occur significantly less frequently. At the same time, hygienic risks caused by microbial contamination or residues that could compromise successful sterilization and therefore patient safety are reduced.
Optimized water treatment for patient safety and efficient processes
In medical facilities, patient safety is always the highest priority. Modern and standards-compliant water treatment plays a crucial role in ensuring safe and reproducible reprocessing procedures. Only a water treatment system designed according to the latest state of technology can guarantee long-term legal security in the reprocessing of medical devices.
At the same time, facilities benefit operationally and economically. Optimized workflows, reduced damage to instruments and improved operational reliability lower costs and increase efficiency in daily operations. Furthermore, relieving staff through stable and reliable processes reduces stress and increases employee satisfaction.
Your benefits with Heyl Neomeris Clinical Solutions
- Modern DI water systems for medical facilities and laboratories
- Compliance with current requirements and guidelines for process water quality
- Reduced scaling, corrosion and damage to medical instruments
- Improved patient safety through stable and hygienic reprocessing processes
- More efficient workflows and reduced workload for staff
With Heyl Neomeris Clinical Solutions you benefit from reliable water treatment, optimized reprocessing processes and long-term operational reliability – ensuring safe instrument reprocessing and the highest quality standards in medical facilities.
Filter products
The modular water treatment system was specially developed for the outpatient care sector. While retaining the overall geometry, the system can be adapted to the different degrees of water hardness in Germany, the quantities required in different outpatient centers, as well as to the initial water quality including any treatment steps on the part of the supplier. The modularity offers the decisive advantage that the overall concept can be adapted to the respective water type or composition as well as the treatment process of the supplier. Concept Demineralized water treatment for the outpatient sector Use of demineralized water in the outpatient sector Fully demineralized water (demineralized water) plays a central role in the outpatient medical sector, particularly in the reprocessing of medical devices, in laboratory applications and in the final rinse for mechanical instrument reprocessing. The aim is to avoid residues that could be caused by minerals, salts or other substances contained in tap water. For safe use, demineralized water must meet defined quality requirements: The conductivity must be below 0.1 µS/cm. This indicates that it contains almost no dissolved salts or ions. The silicate content must not exceed 0.4 g/l to avoid silicate deposits on medical instruments that could impair functionality or lead to hygienic risks. Only if these limit values are adhered to can residue-free and gentle reprocessing be guaranteed that meets the hygiene requirements in the outpatient sector. This is particularly relevant in dental practices, dermatology, endoscopy and in outpatient operating theatres, where deionized water is used for final rinsing or for steam generators in sterilization processes, among other things. The components used are listed below: Cabinet System separator Filter system (pre-filter & activated carbon filter) Softening system Reverse osmosis system Permeate tank 100 liters (volume can be adjusted) Pressure boosting station Two-stage mixed bed UV system (optional) Pyrogen filter (optional) Ring line in front of the mixing bed if the consumers are not removed to prevent contamination Brine lifting system (optional) Testomat 808 SIO2 (silicate measurement) Conductivity measurement NeoTecMaster (optional) Performance of the system Depending on the design of the system, 90 l, 150 l, 230 l or 300 l deionized water can be produced per hour. The capacity of the permeate tank can be adjusted, but must be positioned outside the cabinet due to the larger dimensions including the pressure booster station from a capacity of > 150 l/ (depending on the application). Shut-off via system separator The installation of a system separator is mandatory to protect the drinking water network from contamination by treated water or changes to the natural composition of the drinking water fed in due to its technical treatment. The system has an integrated system separator (type BA), which is located directly behind the Aqua-Stop of the water connection. Aqua-Stop (solenoid valve shut-off) An Aqua-Stop is a safety mechanism used in water supply systems to stop or limit the flow of water if a fault or leakage occurs. The Aqua-Stop is located directly behind the main water connection of the system as the first element. The associated solenoid valve is coupled with two sensors, one of which is integrated in the bottom tray of the cabinet and the second is located outside at the level of the tank and the pressure booster station. Filter The pre-filter section is a filter unit consisting of a pre-filter and an activated carbon filter. Its main purpose is to protect downstream softening and osmosis systems that could be damaged by impurities in the water. Water softener The water softener removes the hardness constituents (calcium and magnesium) from the drinking water and replaces them with sodium. The function is based on an ion exchange process and ensures that the reverse osmosis membranes are reliably protected against clogging. Reverse osmosis In reverse osmosis, the natural osmotic process is reversed. The softened water is pumped through a membrane under pressure, whereby the membrane only allows water molecules and very small molecules to pass through and retains larger particles such as salts, bacteria, fours and other impurities. The installed reverse osmosis has a retention rate of approx. 98% in relation to all substances dissolved in the water. Permeate tank The built-in round tank offers advantages in terms of stability, cleaning and space requirements. The uniform shape ensures that the water is treated and stored efficiently. The optimized tank geometry prevents the potential growth of microbiological contamination and thus meets the high requirements for media purity to a greater extent. Pressure booster station The pressure booster station ensures that the connected consumers are supplied with the required operating pressure and flow rate. This enables an optimized and needs-based media supply. Mixing bed The two-stage mixing bed (connected in series) is a so-called pole mixer. Due to the special composition of the resin contained in the cartridges, all dissolved substances remaining in the water are reliably removed. The resin used is highly effective against silicates, which have a particularly negative impact on the reprocessing of medical products. The mixing bed is also the first stage of the recirculation process when using the optionally available buffer tank system. Pyrogen filter A pyrogen filter is a special type of filter used in water treatment to remove pyrogens from the water. Pyrogens are substances that can cause an immunological reaction in the body, in particular an increase in body temperature. These are usually endotoxins that are released by bacteria such as Escherichia coli (E. coli). Water disinfection by UV irradiation The development of water disinfection using UV radiation has made considerable progress in recent years due to its simplicity and efficiency. The UV-C rays generated, which are significantly more intense than sunlight, are therefore used to disinfect water in order to counteract water contamination. They enable the removal of legionella, microbes, bacteria, viruses and protozoa while respecting the environment. Testomat® 808 SiO2 silicate measuring device A Testomat®808 SiO2 silicate is used for permanent silicate monitoring. The Testomat®808 SiO2 is a measuring instrument that is used to determine the silicate content in water. The use of the Testomat 808®SiO2 ensures reliable compliance with the limit value for SiO2 of 0.4 mg/l recommended by the DGSV and AKI. Conductivity measurement Continuous monitoring of conductivity in the range of 0-10 μS/cm on the second mixing bed. For the reprocessing of medical devices, a conductivity of <1 µS/cm is recommended for the water used for the cleaning & disinfection and sterilization process. The conductivity measurement used continuously monitors whether the conductivity falls below this value. NeoTecMaster® 5 inch with housing Data acquisition, visualization and processing are just some of the relevant topics in the field of modern water treatment. The networking of different measuring systems and their integration into process automation is an elementary component here. The NeoTecMaster® was specially developed for this task and is a manufacturer-independent multi-parameter system. Cabinet systems Only a minimum footprint of 1.60 m x 1 m is required for installation. The module consists of 2 cabinets, each 80 cm wide and 60 cm deep. It is possible to work with double hinged doors, resulting in a room depth of 1m due to the depth of 60cm and a double hinged door with a dimension of 40cm. The cabinets used are made of sturdy sheet steel modules and have a high-quality surface coating. Viewing window Viewing windows are installed in Rittal enclosures to provide an overview of the measurement technology. The use of viewing windows in Rittal enclosure systems has several advantages. They enable a visual inspection of the devices in the enclosure without having to open the enclosure. This facilitates the monitoring, maintenance and troubleshooting of components without compromising the integrity of the enclosure. The viewing windows are usually made of a transparent material such as glass. Notes: Viewing windows in Rittal enclosures are only available for single-leaf doors. If this option is selected, please note that the required minimum room depth increases from 100 cm to 140 cm.Abwasser Abführung über Solehebeanlage (optional) As an optional component, the treatment plant can be extended to include an integrated wastewater lifting unit, which pumps the generated and collected wastewater into the sewer system. The main wastewater volume flows here are the wastewater from the regeneration of the softening system and the concentrate from the reverse osmosis. Collecting tray The integrated drip tray is used to detect leaks and is therefore a safety device part of the cabinet systems.The optional components of the system:Viewing windowLighting
The modular water treatment system was specially developed for the outpatient care sector. While retaining the overall geometry, the system can be adapted to the different degrees of water hardness in Germany, the quantities required in different outpatient centers, as well as to the initial water quality including any treatment steps on the part of the supplier. The modularity offers the decisive advantage that the overall concept can be adapted to the respective water type or composition as well as the treatment process of the supplier. Concept Demineralized water treatment for the outpatient sector Use of demineralized water in the outpatient sector Fully demineralized water (demineralized water) plays a central role in the outpatient medical sector, particularly in the reprocessing of medical devices, in laboratory applications and in the final rinse for mechanical instrument reprocessing. The aim is to avoid residues that could be caused by minerals, salts or other substances contained in tap water. For safe use, demineralized water must meet defined quality requirements: The conductivity must be below 0.1 µS/cm. This indicates that it contains almost no dissolved salts or ions. The silicate content must not exceed 0.4 g/l to avoid silicate deposits on medical instruments that could impair functionality or lead to hygienic risks. Only if these limit values are adhered to can residue-free and gentle reprocessing be guaranteed that meets the hygiene requirements in the outpatient sector. This is particularly relevant in dental practices, dermatology, endoscopy and in outpatient operating theatres, where deionized water is used for final rinsing or for steam generators in sterilization processes, among other things. The components used are listed below: Cabinet System separator Filter system (pre-filter & activated carbon filter) Softening system Reverse osmosis system Permeate tank 100 liters (volume can be adjusted) Pressure boosting station Two-stage mixed bed UV system (optional) Pyrogen filter (optional) Ring line in front of the mixing bed if the consumers are not removed to prevent contamination Brine lifting system (optional) Testomat 808 SIO2 (silicate measurement) Conductivity measurement NeoTecMaster (optional) Performance of the system Depending on the design of the system, 90 l, 150 l, 230 l or 300 l deionized water can be produced per hour. The capacity of the permeate tank can be adjusted, but must be positioned outside the cabinet due to the larger dimensions including the pressure booster station from a capacity of > 150 l/ (depending on the application). Shut-off via system separator The installation of a system separator is mandatory to protect the drinking water network from contamination by treated water or changes to the natural composition of the drinking water fed in due to its technical treatment. The system has an integrated system separator (type BA), which is located directly behind the Aqua-Stop of the water connection. Aqua-Stop (solenoid valve shut-off) An Aqua-Stop is a safety mechanism used in water supply systems to stop or limit the flow of water if a fault or leakage occurs. The Aqua-Stop is located directly behind the main water connection of the system as the first element. The associated solenoid valve is coupled with two sensors, one of which is integrated in the bottom tray of the cabinet and the second is located outside at the level of the tank and the pressure booster station. Filter The pre-filter section is a filter unit consisting of a pre-filter and an activated carbon filter. Its main purpose is to protect downstream softening and osmosis systems that could be damaged by impurities in the water. Water softener The water softener removes the hardness constituents (calcium and magnesium) from the drinking water and replaces them with sodium. The function is based on an ion exchange process and ensures that the reverse osmosis membranes are reliably protected against clogging. Reverse osmosis In reverse osmosis, the natural osmotic process is reversed. The softened water is pumped through a membrane under pressure, whereby the membrane only allows water molecules and very small molecules to pass through and retains larger particles such as salts, bacteria, fours and other impurities. The installed reverse osmosis has a retention rate of approx. 98% in relation to all substances dissolved in the water. Permeate tank The built-in round tank offers advantages in terms of stability, cleaning and space requirements. The uniform shape ensures that the water is treated and stored efficiently. The optimized tank geometry prevents the potential growth of microbiological contamination and thus meets the high requirements for media purity to a greater extent. Pressure booster station The pressure booster station ensures that the connected consumers are supplied with the required operating pressure and flow rate. This enables an optimized and needs-based media supply. Mixing bed The two-stage mixing bed (connected in series) is a so-called pole mixer. Due to the special composition of the resin contained in the cartridges, all dissolved substances remaining in the water are reliably removed. The resin used is highly effective against silicates, which have a particularly negative impact on the reprocessing of medical products. The mixing bed is also the first stage of the recirculation process when using the optionally available buffer tank system. Pyrogen filter A pyrogen filter is a special type of filter used in water treatment to remove pyrogens from the water. Pyrogens are substances that can cause an immunological reaction in the body, in particular an increase in body temperature. These are usually endotoxins that are released by bacteria such as Escherichia coli (E. coli). Water disinfection by UV irradiation The development of water disinfection using UV radiation has made considerable progress in recent years due to its simplicity and efficiency. The UV-C rays generated, which are significantly more intense than sunlight, are therefore used to disinfect water in order to counteract water contamination. They enable the removal of legionella, microbes, bacteria, viruses and protozoa while respecting the environment. Testomat® 808 SiO2 silicate measuring device A Testomat®808 SiO2 silicate is used for permanent silicate monitoring. The Testomat®808 SiO2 is a measuring instrument that is used to determine the silicate content in water. The use of the Testomat 808®SiO2 ensures reliable compliance with the limit value for SiO2 of 0.4 mg/l recommended by the DGSV and AKI. Conductivity measurement Continuous monitoring of conductivity in the range of 0-10 μS/cm on the second mixing bed. For the reprocessing of medical devices, a conductivity of <1 µS/cm is recommended for the water used for the cleaning & disinfection and sterilization process. The conductivity measurement used continuously monitors whether the conductivity falls below this value. NeoTecMaster® 5 inch with housing Data acquisition, visualization and processing are just some of the relevant topics in the field of modern water treatment. The networking of different measuring systems and their integration into process automation is an elementary component here. The NeoTecMaster® was specially developed for this task and is a manufacturer-independent multi-parameter system. Cabinet systems Only a minimum footprint of 1.60 m x 1 m is required for installation. The module consists of 2 cabinets, each 80 cm wide and 60 cm deep. It is possible to work with double hinged doors, resulting in a room depth of 1m due to the depth of 60cm and a double hinged door with a dimension of 40cm. The cabinets used are made of sturdy sheet steel modules and have a high-quality surface coating. Viewing window Viewing windows are installed in Rittal enclosures to provide an overview of the measurement technology. The use of viewing windows in Rittal enclosure systems has several advantages. They enable a visual inspection of the devices in the enclosure without having to open the enclosure. This facilitates the monitoring, maintenance and troubleshooting of components without compromising the integrity of the enclosure. The viewing windows are usually made of a transparent material such as glass. Notes: Viewing windows in Rittal enclosures are only available for single-leaf doors. If this option is selected, please note that the required minimum room depth increases from 100 cm to 140 cm.Abwasser Abführung über Solehebeanlage (optional) As an optional component, the treatment plant can be extended to include an integrated wastewater lifting unit, which pumps the generated and collected wastewater into the sewer system. The main wastewater volume flows here are the wastewater from the regeneration of the softening system and the concentrate from the reverse osmosis. Collecting tray The integrated drip tray is used to detect leaks and is therefore a safety device part of the cabinet systems.The optional components of the system:Viewing windowLighting
Under-sink system– Compact Solutions for Pure Water Quality Undercounter systems are space-saving, efficient water treatment solutions designed for discreet installation beneath work surfaces. They are indispensable in sensitive environments such as medical technology, laboratory furniture, dental clinics, and the MedTec industry. These systems reliably deliver purified water – demineralized (DI) water – exactly where it's needed. Advantages of Under-sink system: Compact design for integration into furniture and workspaces Easy to incorporate into existing supply systems Reliable multi-stage water purification Hygienic dispensing options for medical applications Example from the HeylNeomeris Range: NeoPureMini – Multi-Stage Under-sink Diluat System Pre-assembled on a stable frame and ready to connect, the NeoPureMini is ideal for installation under lab benches, in dental offices, or in medical furniture modules. With multi-stage filtration (including activated carbon, fine filtration, and optional UV stage), it provides high-purity DI water for stringent hygiene requirements in the sterilization of medical instruments in outpatient centers, operating rooms, and clinics.
MB A6K4 is a high capacity mixed bed ion exchange resin consisting of a mixture of strongly basic anion resin and a strongly acidic cation resin for direct water purification.The conductivity is about 0.06 µm/cm.Suitable for use in non-regenerable cartridges, high efficiency deionisation for silica removal and ultra pure water applications.Packed in 25 litre bagsPolymer matrix: gel polystyrene cross-linked with DVB.Ionic form, as supplied: H+ / OH-Physical shape and appearance: Spherical beadsSphericity: Min. 95%Particle size range (US Standard Screen): 1.25 - 0.315mm, wet.Particle size: +1.2mm < 5% ; -0.3mm < 1%Water retention H+: 45 - 50%Water retention OH-: 53 - 60%Shipping weight (approx.): 700-740 g/lMax. Temp. non-regenerative: 100°CMax. Temp. regenerative: 60°CpH-value range: 0-14Recommended operating conditions:Minimum bed depth should be 0.6m (24")Service flow rate should be 20-60 BV/hourProlonged exposure to strong oxidising agents such as chlorine, hydrogen peroxide and concentrated nitric acid will deteriorate the structural backbone of the resin and should be avoided.Mixture Resin:Anions: 60%Cations: 40%Purchase options:Single purchase - 25 ltr. (item no. 896495)1/2 pallet - 500 ltr. (Art.-No. 896496)1 pallet - 1050 ltr. (art.-no. 896497)
Content: 1050 Liter (€5.40 / 1 Liter)
Precise Water Hardness Analysis for Automated Process and System Monitoring with the Testomat EVO TH Fully automatic water hardness determination via titration The Testomat EVO automatically detects the water level when filling the measuring chamber and can also operate for extended periods in BOB mode without constant supervision. With an integrated SD card or optionally an SDHC card (2 GB), measurement data and messages/alarms can be recorded. The menu is available in multiple languages, and firmware updates can be conveniently applied via the SD card. Analog outputs and serial interfaces allow external processing of measurement data. Certified and Cost-Effective Standalone Water Hardness Meter With the Testomat EVO, you benefit from stable, low-maintenance continuous operation, minimal consumption of indicator solution and water, as well as versatile data communication via RS232 or 0/4–20 mA signals. Certification according to relevant safety and TÜV standards (WÜH certification for boiler houses) and the compact design make the EVO a robust and efficient solution for demanding measurement tasks. Applications for the Testomat EVO Water treatment Drinking water systems Industrial boilers Process water monitoring When purchasing the Testomat EVO online, you receive, in addition to a 3 % online discount on Heyl devices, a free indicator of your choice. Frequently asked questions How long is the warranty period for the Testomat EVO TH? The warranty period for the Testomat EVO TH series is 2 years from delivery. Where can I view or download the operating instructions? The operating instructions can be viewed or downloaded in the online shop, either directly with the item or in a separate download area. How can the values be read out on the Testomat EVO TH? This is possible with the integrated SD card. More detailed information on data readout can be found in the operating instructions. Can the warranty on my Testomat device be extended? A warranty extension on a newly purchased Testomat device is generally possible from 24 to 36 months. The warranty period can thus be extended by one year. The prerequisite for this is that the extension is made within the first three months after the date of purchase. You can access the device warranty extension directly via your online shop customer account. Does the Testomat EVO TH have different spare parts and service sets than the Testomat ECO? No, the spare parts for the Testomat EVO TH and the Testomat ECO are identical. A selection of spare parts for the specific device can also be found in the respective device operating instructions. How high are the follow-up costs for chemicals? Chemical consumption depends on the number of analyses performed with the Testomat EVO TH. Consumption can be determined using our indicator consumption calculator in the online shop. How often does the device need to be serviced? The manufacturer recommends servicing the device once or twice a year. The maintenance interval for the Testomat EVO TH is therefore 6-12 months. Can the device be serviced by a service partner? Yes, maintenance can be carried out by an authorised Heyl Neomeris service partner. Please feel free to contact us if required via vertrieb@heylneomeris.de , so that we can find the right technician for your region. Can the device be sent in for repair (cost estimate)? Yes, the defective device can be sent to our address. A description of the fault should be included with the return shipment and the indicator must be removed from the device before returning it. Once we have received the defective device, you will first receive a cost estimate for the expected repair costs. The repair will only be carried out after prior approval.
Focus on efficiency, quality and safety The supply of demineralized water (demineralized water) is of central importance in many areas of a clinic - for example in central sterilization, laboratory analysis or medical technology. At the same time, the requirements for efficiency, operational safety and hygiene are constantly increasing. Our on-site process analysis provides you with a structured evaluation of the existing demineralized water treatment - with a focus on efficiency, supply reliability and compliant implementation. Our consulting approach includes, among other things System survey and weak point analysis Recording the entire process chain - from the raw water supply to softening, desalination, filtration, storage and distribution systems. Comparison with the actual water demand Checking whether system capacities, retention times and storage volumes match the current and future usage situation. Evaluation of technical and organizational interfaces z. e.g. transfer points to medical technology, automatic rinsing cycles, instrument logistics, redundancy concepts, etc. Risk analysis with regard to microbiological and technical weak points incl. recommendations for sampling, avoidance of downtime contamination and material safety. Economic efficiency analysis Consideration of e.g. use of chemicals, personnel costs and optimization possibilities. As part of our process analysis, we work with you to determine The relevant withdrawal points in the supply system (e.g. after the demineralization plant, at points of consumption, in the return area) The correct sampling technique Possible influences on the measurement results (e.g. dead volume, stagnation, material compatibility) Requirements for microbiological and chemical-physical analysis Adapted to the medical requirements of the facility The aim of sampling is to obtain a realistic picture of the water quality in the facility and to identify potential risks at an early stage. Our independent analysis supports you in complying with regulatory requirements, strengthening internal quality assurance measures and ensuring the long-term operational safety of your demineralized water treatment. The results are documented in a clearly structured report - including an assessment and specific recommendations for optimization. Our process analysis creates transparency, identifies optimization potential and forms the basis for well-founded investment decisions or quality assurance measures. You receive clear documentation with specific recommendations for action - practical, independent and tailored to your clinic.
The Testomat® 808 is a compact analyser for online measurement of water hardness according to the principle of "limit value monitoring with colour change" in the measuring range 0.02 - 5 ° dH (0.4 - 89 ppm). Applications of the continuous residual hardness monitoring are e.g.: Reverse osmosis systems, boiler feed water supply Soft water for commercial purposes, ultrapure water systems. In view of the fact that the Testomat® 808 is suitable for use in multi-parameter systems due to its 4-20mA signal output, we hereby offer you the Testomat® 808 in conjunction with the NeoTecMaster® Multicontroller, which was specially developed by our company, as a package solution at a preferential price. The 4-channel NeoTecMaster® Multicontroller included in this package enables the processing of up to four measurement signals. Via the 4-20mA NeoTec slave input module connected to the NeoTecMaster®, the data is transmitted to the NeoTecMaster® and used to display the measured value, the trend and the status messages on the 5-inch screen. In addition, the NeoTecMaster® has an RS232 interface as well as a Modbus RTU input, which you can use freely after brief technical consultation with us. (Pre-check whether your existing measurement technology to be integrated requires adjustments). The NeoTecMaster® can be systematically supplemented with further optional NeoTec modules (function / signal converter modules) as required. This allows the future realisation of further control concepts in a flexible way. Two modules which fundamentally extend the range of functions and are already included in the scope of delivery are our NeoTec slave relay module and the 4x 4-20mA input module. This allows you to add potential-free relay contacts to the overall system and to integrate and visualise further system technology such as sensors via the 4x 4-20mA input module. You can freely assign the relay contacts to the incoming measurement signals and thus, for example, implement simple limit value-related control concepts as well as output measurement value-related messages. Further advantages of the NeoTecMaster: Simple operation Integration of the Testomat® device world, here in connection with the Testomat® 808 Integration into the existing control cabinet, alternatively we offer our NeoTecMaster® enclosure Modular range of functions can be extended by NeoTec slave and signal converter modules (measurement, control, regulation) Available as built-in or surface-mounted variant Structured continuous data recording on the integrated SD card or optionally available SDHC card (2Gbyte) as a file in CSV format In addition, there are the proven functionalities of the Testomat® 808: Indication of limit value undershoot or overshoot: green / red LED Modern indicator pump system Automatic measuring sequence with low water consumption Direct error and indicator quantity display Internal and external flushing of the measuring chamber by manual control Control of an external flush valve Three potential-free relays for: External flush valve control Limit value evaluation External control and / or alarm processing Safety check for 72-hour operation without supervision Indicator quantities: 100 and 500 ml bottles 4 - 20 mA interface for defined status and error messages RS 232 interface for firmware updates General information Water connection and operating pressure: Depending on unit version: 0.3 - 1 bar / 0.3 x 105 to 4 x 105 Pa 1 - 4 bar / 1 x 105 to 4 x 105 Pa (from 4 to 8 bar, a pressure reducer must be used (special accessory)) Water inlet: opaque hose with 6 mm outer diameter/4 mm inner diameter Water outlet: hose with 6 mm outer diameter/4 mm inner diameter Water temperature: 10 to 40 °C From 4 bar, a separately available pressure reducer must be used. Please use only the indicators approved for Testomat® 808! Optional accessories: NeoTecMaster unit hood
The regular validation of the entire reprocessing process and its repeated implementation in the event of interventions or changes within the reprocessing process is an essential instrument for demonstrating process reliability. In the course of our work as technical experts, we verify the overall process, assist you with sustainable documentation, continuously monitor the effectiveness of the measures introduced, coordinate the involvement of all process participants and make recommendations for the involvement of authorised external accredited bodies and specialist companies.
Testomat 808: Continuous Hardness Limit Monitoring Online measurement of residual water hardness with automatic color change Measurement Principle and Technical Features Modern indicator pump system supporting an automated process with minimal reagent and water consumption. Internal and external flushing options, manual safety check for up to 72 hours of unattended operation (BOB operation), and interfaces for 4–20 mA signals and RS232 firmware updates. Purchase Benefits 3% shop discount when purchasing a Testomat 808 Free of charge: original Heyl indicator for hardness measurement Frequently asked questions How long is the warranty for Testomat devices? The manufacturer's warranty period for the Testomat device series from Heyl is two years from the date of delivery. Where can I view or download the operating instructions? The operating instructions are included with the Testomat upon delivery and can be downloaded at any time from our online shop (www.heylneomeris.de) under the menu item – Service/Help – Download Operating Instructions. Can the warranty be extended? A warranty extension to three years is possible for a newly purchased device if a subscription for the corresponding indicator delivery is taken out. The subscription can be taken out easily and conveniently in the customer account under Subscriptions. The device warranty is extended from 24 months to 36 months after taking out the subscription. The prerequisite for this is that the subscription is taken out within 3 months of the purchase date. A subsequent warranty extension is not possible. Does the Testomat 808 have different spare parts and service sets to the Testomat 808 SiO2? Yes, there are some differences. More detailed information on the individual parts can be found in the operating instructions under ‘Spare Parts List’. How high are the follow-up costs for chemicals? The necessary use of indicators depends on the measurement intervals, which can be set via the device. The actual chemical consumption can be determined independently and individually for the respective application using our indicator or reagent consumption calculator in the shop. Indicators consumption calculator Reagent Consumption Calculator How often does the Testomat 808 need to be serviced? According to the manufacturer, regular maintenance is recommended. The recommended maintenance interval is between 6 and 12 months. Can the device be serviced by a service partner? With our nationwide service partner network, we can arrange for maintenance to be carried out by one of our service partners in Germany and Austria at any time. Please send us your enquiry to vertrieb@heylneomeris.de. Can the device be sent in for repair (cost estimate)? Of course, we at HeylNeomeris offer a repair service. To do this, we need the completed checklist from the operating instructions. The maintenance request can be sent to vertrieb@heylneomeris.de. If you have any further questions, please contact our service team on the service hotline +49 (0) 5121 7609 99.
MB A6K4 is a high capacity mixed bed ion exchange resin consisting of a mixture of strongly basic anion resin and a strongly acidic cation resin for direct water purification.The conductivity is about 0.06 µm/cm.Suitable for use in non-regenerable cartridges, high efficiency deionisation for silica removal and ultra pure water applications.Packed in 25 litre bagsPolymer matrix: gel polystyrene cross-linked with DVB.Ionic form, as supplied: H+ / OH-Physical shape and appearance: Spherical beadsSphericity: Min. 95%Particle size range (US Standard Screen): 1.25 - 0.315mm, wet.Particle size: +1.2mm < 5% ; -0.3mm < 1%Water retention H+: 45 - 50%Water retention OH-: 53 - 60%Shipping weight (approx.): 700-740 g/lMax. Temp. non-regenerative: 100°CMax. Temp. regenerative: 60°CpH-value range: 0-14Recommended operating conditions:Minimum bed depth should be 0.6m (24")Service flow rate should be 20-60 BV/hourProlonged exposure to strong oxidising agents such as chlorine, hydrogen peroxide and concentrated nitric acid will deteriorate the structural backbone of the resin and should be avoided.Mixture Resin:Anions: 60%Cations: 40%Purchase options:Single purchase - 25 ltr. (item no. 896495)1/2 pallet - 500 ltr. (Art.-No. 896496)1 pallet - 1050 ltr. (art.-no. 896497)
Content: 500 Liter (€5.54 / 1 Liter)
Our 4- or 8- channel system allows the processing of up to four or eight measurement signals. For this purpose, 4-20 mA/ RS232 as well as Modbus RTU are available as signal inputs. Based on the received data a visualization as well as a trend display takes place. Through modular addition of optional modules (slaves) the realization of popular control concepts is possible.Advantages:Simple operation Integration of the Testomat® device world Integration into the existing control cabinet, alternatively we offer our NeoTecMaster® housingModular function range expandable by NeoTec slave modules (measure, control, control)Available as installation variant or structure variant Contents: NeoTecMaster® 5 inch - 4 channel system (optionally expandable to 8 channels) with Modbus interface and RS232 input for data communicationNeoTec Slave 4-20mA module (inputs: 8x 20mA)NeoTecMaster® IP66 housing for 5" display, light grey with front foilUSB stick for NeoTecMaster® 8GBInstallation of NeoTecMaster® in housing incl. parameterisation and cabling of the NeoTecMaster®Universal power supply 24V/6A DC (100-240V AC) (144 Watt)
Our 4- or 8- channel system allows the processing of up to four or eight measurement signals. For this purpose, 4-20 mA/ RS232 as well as Modbus RTU are available as signal inputs. Based on the received data a visualization as well as a trend display takes place. Through modular addition of optional modules (slaves) the realization of popular control concepts is possible.Advantages:Simple operation Integration of the Testomat® device world Integration into the existing control cabinet, alternatively we offer our NeoTecMaster® housingModular function range expandable by NeoTec slave modules (measure, control, control)Available as installation variant or structure variant
Reliable and economical demineralized water treatment (demineralized water) is indispensable in sterile processing. However, processes, system status and operating costs are subject to constant change. As part of our basic on-site analysis, you will receive a well-founded and independent assessment of your existing demineralized water treatment system - directly at your location. Our consulting approach aims to identify optimization potential at an early stage and make it economically viable. Among other things, we look at Plant technology and dimensioning Equipment and feed technology Instruments used In sensitive environments such as hospitals, the quality of the demineralized water used is crucial - especially in areas such as sterile goods processing, laboratory diagnostics or medical technology. On request, we can also carry out targeted and professional water sampling at representative sampling points for a fee. Some of the water samples taken are analyzed on site using photometric measurements and then sent to an accredited laboratory. The results are documented in a clearly structured report - including an assessment and specific recommendations for optimization.
The reliable supply of demineralized water (demineralized water) to the AEMP is a critical factor for the flawless reprocessing of medical devices. Decision-makers in hospitals are faced with key questions: What are the requirements for water quality? Which pipe materials are suitable? How can a standard-compliant, hygienic and economical solution be planned and implemented? We support you in all project phases - from technical planning to material selection and implementation - with the following focal points: Determination of demand & load profiles: Analysis of peak consumption (e.g. washer-disinfectors, autoclaves), design of water treatment and storage solutions according to AEMP capacity. We take into account not only current but also future requirements. Requirements of current DGSV and AKI guidelines: Ensuring compliance with the required limit values for conductivity and silicates. Line design & material selection Technology concept: selection of suitable DI system technology Economic efficiency analysis: focus on life cycle costs, energy efficiency and maintenance costs. Our manufacturer-independent advice ensures that your investment functions reliably, compliantly and efficiently in the long term - in the interests of patient, operator and process safety.
Proposed use: for the regeneration of water softeners Composition: evaporated salt (min. 99.9% NaCl) Dimensions / weight of tablet: ø25mm / 14g Moisture content: < 0.08 Filling weight: 10kg per sack Type of packaging: PE film Storage description: store dry and well closed Certifications: ISO 9001, ISO 14001 and IFS Standard: The product complies with the following standards. EN 973:2009 Products for the treatment of water intended for human consumption - Sodium chloride for regenerating ion exchange resins -Type A EN 16401:2013 Products for the treatment of swimming pool water - Sodium chloride for use in electrochemical chlorine production plants - Type A EN 14805:2022 Products for the treatment of water intended for human consumption - Sodium chloride for on-site electrochemical production of chlorine by membrane-free processes - Type 1 EN 16370:2022 Products for the treatment of water intended for human consumption - Sodium chloride for the on-site electrochemical production of chlorine by means of membrane cells - Quality 2 Purchase options: Single purchase: 1x 10kg sack (Art.-No. 896467) Pallet purchase: 100x 10kg sacks (Art.-No. 896498)
Water sterilisation by UV irradiation The development of water sterilisation using UV radiation has made considerable progress in recent years due to its simplicity and efficiency. The UV-C rays generated, which are significantly more intense than sunlight, are therefore used to disinfect water in order to counteract water contamination. They make it possible to remove legionella, microbes, bacteria, viruses and protozoa while respecting the environment. The irradiation process is therefore an ideal solution for killing microorganisms in water and helps to make it drinkable from a bacteriological point of view. However, it is important to note that water is only considered drinking water once the chemical parameters have been checked and deemed satisfactory. Applications - Origin of the water Rainwater: UV treatment extends the range of applications and offers increased safety during use Well water: Avoidance of possible contamination by pathogens Tap water: UV treatment extends the area of application and increases safety. Spring water, surface water: Guarantees constant water quality that is flawless from a bacteriological point of view. Storage water in containers (caravan, boat...): Use of stored water for sanitary purposes. Areas of application General nutrition, bath and shower Cooking Large-volume refrigerators Cold water fountains Aquarium Cleaning food Advantages Quick and easy installation Completely physical sterilisation through UV radiation Natural water treatment without additives and without the risk of chemical overdose No unpleasant taste or odour Effective methods for combating microorganisms that cause disease in humans No toxic by-products Low maintenance Frequently asked questions Why do I need a Cintropur UV irradiation system? The system is used for chemical-free disinfection of drinking water. It sustainably reduces germs, viruses and bacteria, thereby also reducing the formation of biofilm. The systems are used both in the drinking water inlet of buildings and in storage tanks for fixed or mobile applications. Can I replace the UV lamp myself and how often is this necessary? Yes, this is easily possible. You can find the appropriate replacement lamp under the spare parts for the product. Please note which type of lamp is installed. We offer 25 watt and 40 watt lamps. The part should be replaced at least once a year to ensure optimum performance. After that, the performance decreases and the device is no longer able to kill germs and bacteria effectively. What accessories do I need? The device can also be ordered as a ‘Trio’ version. This is a useful package consisting of UV irradiation and particle and activated carbon filters. The filters help to remove any remaining particles and odours from the water. This ensures that your water system is optimally protected.
Water sterilisation by UV irradiation The development of water sterilisation using UV radiation has made considerable progress in recent years due to its simplicity and efficiency. The UV-C rays generated, which are significantly more intense than sunlight, are therefore used to disinfect water in order to counteract water contamination. They make it possible to remove legionella, microbes, bacteria, viruses and protozoa while respecting the environment. The irradiation process is therefore an ideal solution for killing microorganisms in water and helps to make it drinkable from a bacteriological point of view. However, it is important to note that water is only considered drinking water once the chemical parameters have been checked and deemed satisfactory. Applications - Origin of the water Rainwater: UV treatment extends the range of applications and offers increased safety during use Well water: Avoidance of possible contamination by pathogens Tap water: UV treatment extends the area of application and increases safety. Spring water, surface water: Guarantees constant water quality that is flawless from a bacteriological point of view. Storage water in containers (caravan, boat...): Use of stored water for sanitary purposes. Areas of application General nutrition, bath and shower Cooking Large-volume refrigerators Cold water fountains Aquarium Cleaning food Advantages Quick and easy installation Completely physical sterilisation through UV radiation Natural water treatment without additives and without the risk of chemical overdose No unpleasant taste or odour Effective methods for combating microorganisms that cause disease in humans No toxic by-products Low maintenance Frequently asked questions Why do I need a Cintropur UV irradiation system? The system is used for chemical-free disinfection of drinking water. It sustainably reduces germs, viruses and bacteria, thereby also reducing the formation of biofilm. The systems are used both in the drinking water inlet of buildings and in storage tanks for fixed or mobile applications. Can I replace the UV lamp myself and how often is this necessary? Yes, this is easily possible. You can find the appropriate replacement lamp under the spare parts for the product. Please note which type of lamp is installed. We offer 25 watt and 40 watt lamps. The part should be replaced at least once a year to ensure optimum performance. After that, the performance decreases and the device is no longer able to kill germs and bacteria effectively. What accessories do I need? The device can also be ordered as a ‘Trio’ version. This is a useful package consisting of UV irradiation and particle and activated carbon filters. The filters help to remove any remaining particles and odours from the water. This ensures that your water system is optimally protected.
Water sterilisation by UV irradiation The development of water sterilisation using UV radiation has made considerable progress in recent years due to its simplicity and efficiency. The UV-C rays generated, which are significantly more intense than sunlight, are therefore used to disinfect water in order to counteract water contamination. They make it possible to remove legionella, microbes, bacteria, viruses and protozoa while respecting the environment. The irradiation process is therefore an ideal solution for killing microorganisms in water and helps to make it drinkable from a bacteriological point of view. However, it is important to note that water is only considered drinking water once the chemical parameters have been checked and deemed satisfactory. Applications - Origin of the water Rainwater: UV treatment extends the range of applications and offers increased safety during use Well water: Avoidance of possible contamination by pathogens Tap water: UV treatment extends the area of application and increases safety. Spring water, surface water: Guarantees constant water quality that is flawless from a bacteriological point of view. Storage water in containers (caravan, boat...): Use of stored water for sanitary purposes. Areas of application General nutrition, bath and shower Cooking Large-volume refrigerators Cold water fountains Aquarium Cleaning food Advantages Quick and easy installation Completely physical sterilisation through UV radiation Natural water treatment without additives and without the risk of chemical overdose No unpleasant taste or odour Effective methods for combating microorganisms that cause disease in humans No toxic by-products Low maintenance Frequently asked questions Why do I need a Cintropur UV irradiation system? The system is used for chemical-free disinfection of drinking water. It sustainably reduces germs, viruses and bacteria, thereby also reducing the formation of biofilm. The systems are used both in the drinking water inlet of buildings and in storage tanks for fixed or mobile applications. Can I replace the UV lamp myself and how often is this necessary? Yes, this is easily possible. You can find the appropriate replacement lamp under the spare parts for the product. Please note which type of lamp is installed. We offer 25 watt and 40 watt lamps. The part should be replaced at least once a year to ensure optimum performance. After that, the performance decreases and the device is no longer able to kill germs and bacteria effectively. What accessories do I need? The device can also be ordered as a ‘Trio’ version. This is a useful package consisting of UV irradiation and particle and activated carbon filters. The filters help to remove any remaining particles and odours from the water. This ensures that your water system is optimally protected.
Proposed use: for the regeneration of water softeners Composition: evaporated salt (min. 99.9% NaCl) Dimensions / weight of tablet: ø25mm / 14g Moisture content: < 0.08 Filling weight: 25kg per sack Type of packaging: PE film Storage description: store dry and well closed Certifications: ISO 9001, ISO 14001 and IFS Standard: The product complies with the following standards... EN 973:2009 Products for the treatment of water intended for human consumption - Sodium chloride for regenerating ion exchange resins -Type A EN 16401:2013 Products for the treatment of swimming pool water - Sodium chloride for use in electrochemical chlorine production plants - Type A EN 14805:2022 Products for the treatment of water intended for human consumption - Sodium chloride for on-site electrochemical production of chlorine by membrane-free processes - Type 1 EN 16370:2022 Products for the treatment of water intended for human consumption - Sodium chloride for the on-site electrochemical production of chlorine by means of membrane cells - Quality 2 Purchase options: Single purchase: 1x 25kg sack (Art.-No. 896468) Pallet purchase: 40x 25kg sacks - 1000 kg (Art.-No. 896500)
Physical UV Sterilization for Hygienically Clean Water Effective UV-C disinfection without chemicals for reliable water hygiene The Cintropur UV4100 uses UV-C radiation for the physical disinfection of water and reliably reduces microorganisms such as bacteria, viruses, and protozoa. Water treatment is carried out entirely without chemical additives, ensuring that no by-products are formed and that taste and odor remain unaffected. The water flows through a reactor housing in which UV-C radiation inactivates microorganisms without leaving chemical residues. This makes the Cintropur UV4100 a natural and gentle method of water treatment. It is ideally suited for applications where hygienically safe water is required and the use of chemical disinfectants is deliberately avoided. Regular inspection and timely replacement of the UV lamp ensure that disinfection efficiency remains consistently high throughout the entire operating period. Where can the Cintropur UV4100 be used? This UV disinfection system is suitable for numerous applications with high requirements for water hygiene, including: Pharmaceutical industry Food and beverage industry Hospitals and medical facilities Swimming pools and water systems Water management Animal husbandry and breeding (e.g. chickens, rabbits, ducks) What are the benefits of UV sterilization with the Cintropur UV4100? Compared to chemical disinfection methods, physical UV disinfection offers numerous advantages: Easy and fast installation Purely physical disinfection using UV-C radiation Natural water treatment without chemical additives No risk of chemical overdosing No unpleasant taste or odor Effective reduction of pathogenic microorganisms No toxic by-products or residues Low maintenance requirements Frequently asked questions Why do I need a Cintropur UV irradiation system? The system is used for chemical-free disinfection of drinking water. It sustainably reduces germs, viruses and bacteria, thereby also reducing the formation of biofilm. The systems are used both in the drinking water inlet of buildings and in storage tanks for fixed or mobile applications. Can I replace the UV lamp myself and how often is this necessary? Yes, this is easily possible. You can find the appropriate replacement lamp under the spare parts for the product. Please note which type of lamp is installed. We offer 25 watt and 40 watt lamps. The part should be replaced at least once a year to ensure optimum performance. After that, the performance decreases and the device is no longer able to kill germs and bacteria effectively. What accessories do I need? The device can also be ordered as a ‘Trio’ version. This is a useful package consisting of UV irradiation and particle and activated carbon filters. The filters help to remove any remaining particles and odours from the water. This ensures that your water system is optimally protected.
Effective UV Disinfection for Safe Water – Chemical-Free Physical UV-C disinfection for reliable reduction of microorganisms directly in the water system The Cintropur UV2100 uses ultraviolet (UV-C) radiation to physically remove bacteria, viruses, and microorganisms from water. UV-C light disinfects the water, preventing microbial contamination. This method works without chemical additives, leaving the taste, odor, and composition of the water unchanged. UV disinfection occurs directly within the water system and leaves no residues or by-products. The compact unit can be flexibly integrated into pipelines with the appropriate connection sizes and is designed for low-maintenance operation. Physical UV disinfection provides a reliable reduction of microorganisms in water without residues or chemical by-products. It is important to note that water is only considered drinking water once chemical parameters have been checked and deemed safe. Versatile Applications of the UV Disinfection System The CINTROPUR UV2100 is suitable for a wide range of applications requiring reliable microbial reduction in water, including: Pharmaceutical industry Food and beverage industry Hospitals and medical facilities Swimming pools and water installations Water management Animal husbandry and breeding (e.g., chickens, rabbits, ducks) Benefits of Physical UV Disinfection with the CINTROPUR UV2100 The UV disinfection system offers several advantages over chemical methods: Simple and quick installation Purely physical disinfection using UV-C radiation Chemical-free natural water treatment No risk of overdosing No unpleasant taste or odor Effective reduction of pathogenic microorganisms No toxic by-products or residues Low maintenance requirements Frequently asked questions Why do I need a Cintropur UV irradiation system? The system is used for chemical-free disinfection of drinking water. It sustainably reduces germs, viruses and bacteria, thereby also reducing the formation of biofilm. The systems are used both in the drinking water inlet of buildings and in storage tanks for fixed or mobile applications. Can I replace the UV lamp myself and how often is this necessary? Yes, this is easily possible. You can find the appropriate replacement lamp under the spare parts for the product. Please note which type of lamp is installed. We offer 25 watt and 40 watt lamps. The part should be replaced at least once a year to ensure optimum performance. After that, the performance decreases and the device is no longer able to kill germs and bacteria effectively. What accessories do I need? The device can also be ordered as a ‘Trio’ version. This is a useful package consisting of UV irradiation and particle and activated carbon filters. The filters help to remove any remaining particles and odours from the water. This ensures that your water system is optimally protected.
Reliable Monitoring of Water Quality at Extremely Low Conductivity High-precision conductivity meter for ultrapure and process water The N-LF5R meter was developed for continuous monitoring of very low electrical conductivities in aqueous solutions. With a measuring range of 0–5 µS/cm, it delivers meaningful readings even with minimal conductivity changes. The integrated 3/4" screw-in measuring cell allows direct installation into the process flow. Its compact design and low power requirement via 9 V DC operation make the N-LF5R highly flexible. The robust IP65 housing protects the device against dust and splash water, ensuring reliable operation even under demanding conditions. Why precise conductivity measurement is particularly important in the low range Even slight deviations in conductivity can determine the quality of the final product or the safety of a system in many processes. The N-LF5R detects the smallest changes in the 0–5 µS/cm range, which can indicate contamination, material degradation, or process deviations. Benefits of the N-LF5R for monitoring ultrapure and process water The N-LF5R conductivity meter enables early detection of even minimal changes in conductivity in ultrapure and process water. This allows contamination, leaks, material leaching, or process deviations to be identified quickly before they lead to quality issues or equipment damage. The integrated screw-in measuring cell allows direct inline measurement, ensuring continuous and reliable readings without sampling. Combined with the robust IP65 housing, the device is ideal for permanent use in industrial applications where high measurement accuracy and operational reliability are critical. Frequently asked questions Are there other measuring ranges available? The standard measuring ranges can be found in the product's drop-down menu. If the measuring range you require is not listed, don't worry. Simply let us know and we will check whether we can configure the item to suit your needs. Are there other thread sizes available? If the desired connection thread is not listed, that's no problem. Let us know your desired thread and we will check whether we can configure the item for you with the appropriate thread. For enquiries, please contact our service department on +49 (0) 5121 7609 99 or at vertrieb@heylneomeris.de Is it possible to label the conductivity meter with my own company logo so that we can sell it ourselves in future? That's no problem. Please provide us with more detailed information so that we can process your enquiry. Please note that the price will change due to the increased effort involved and that the minimum purchase quantity for product labelling is 100 units.
Pyrogen filter A pyrogen filter is a special type of filter used in water treatment to remove pyrogens from the water. Pyrogens are substances that can cause an immunological reaction in the body, in particular an increase in body temperature. These are usually endotoxins released by bacteria such as Escherichia coli (E. coli). The pyrogen filter consists of a filter element with a very fine pore size and an associated filter housing. The pyrogen filter is available with filter elements of 0.05, 0.1 or 0.2 micrometres, which you can select as required. This enables the filter to effectively retain particles and microorganisms, including pyrogenic bacteria that may be present in the water. In the modular water treatment plant, the pyrogen filter is used after other pre-treatment stages such as filtration and disinfection. After the water has been purified of particles and microorganisms, it is passed through a pyrogen filter to remove any pyrogens. Pyrogen filters are particularly important in industries where pyrogen-free water is crucial, such as in outpatient care, to ensure the optimal quality of surgical instruments. Overall, pyrogen filters play an important role in water treatment to ensure the quality and purity of the water and minimise potential exposure to pyrogenic substances.