Electrodes & Sensors for Temperature Measurement Accurate temperature measurement is essential in many processes, as it directly affects chemical reactions, biological activity, and the accuracy of other parameter measurements. Our temperature probes and sensors deliver fast response times, high accuracy, and long service life—perfect for use in laboratories, industry, and environmental technology.
Typical applications:
- Process monitoring in the food and beverage industry
- Temperature control in water treatment plants
- Industrial processes with sensitive temperature requirements
- Environmental monitoring in water bodies
- Measuring instruments
- Chemistry
- Controls
- Electrodes and sensors
- Dosing technology
- Plant engineering
- Disinfection and Hygiene
- Laboratory & Mobile Measurement Technology
- Accessories
- Training courses
- Service & Company
Filter products
Wall-Mounted Resistance Thermometer by JUMO with Pt100 and Integrated Transmitter with 4–20 mA and Measuring Range -40 to +80 °C JUMO Wall-Mounted Resistance Thermometer with Remote Protection Tube Protection Class IP65 Type: 902520/23-474-1003-1/330,(-40..80°C) The wall-mounted resistance thermometer is suitable for HVAC temperature measurements with direct analog signal transmission. Equipped with Pt100 in a two-wire circuit, an integrated 4 to 20 mA transmitter, and a measuring range of -40 to +80 °C, this version is particularly suitable for robust wall-mounted measuring points with a separated measuring location. This version is designed for wall-mounted measuring points where the temperature value should be recorded at a location slightly removed from the housing and transmitted directly as a current signal. For this purpose, the version is equipped with a remote protection tube. Technical Data Version: Wall-mounted resistance thermometer with remote protection tube Measuring insert: 1 x Pt100 Circuit type: Two-wire circuit Transmitter: 1 x analog, output 4 to 20 mA Measuring range: -40 to +80 °C Note: Measuring range only in combination with transmitter Protection class: IP65 Advantages and Technical Features of this Wall-Mounted Resistance Thermometer remote protection tube for more targeted temperature measurement well suited for wall-mounted measuring points with a separated measuring location no additional external signal conversion required suitable for applications with an extended temperature range up to +80 °C The remote protection tube offers a clear advantage: the sensor can be positioned closer to the actual measuring point while the housing remains mounted separately on the wall. This is practical wherever temperature values should not be measured directly at the housing position but require a small distance from the actual measuring location. In addition, the integrated 4 to 20 mA transmitter provides the temperature signal immediately as a common analog output signal and allows direct connection to suitable controllers or control systems. Especially in building automation and HVAC applications, this is useful when no additional external signal conversion is planned. The associated measuring range is -40 to +80 °C and applies to this version in combination with the transmitter. The housing design is also intended for more demanding installation environments. With protection class IP65, the device is well protected against dust and water. This makes the version particularly suitable for wall-mounted measuring points in technically demanding indoor areas or protected outdoor areas. Typical Applications Wall-mounted measuring points in HVAC applications Building automation Heating, ventilation, and air conditioning systems Measuring points with a slightly remote measuring location Technical indoor areas and protected outdoor areas Frequently Asked Questions What can I use this thermometer for? It is suitable for temperature monitoring in heating, ventilation, air conditioning, and building automation systems. Why does the thermometer have an extended protective sleeve? To allow the temperature to be measured closer to the actual point of interest rather than right at the housing. What temperature range is the thermometer suitable for? Depending on the specific model, the device is designed for temperature ranges of -30 to +60°C, -30 to +90°C, and -40 to +80°C. Is the thermometer suitable for humid environments? Yes, the housing is protected against dust and water jets in accordance with the IP65 rating. Where is this thermometer typically used? It is frequently used in HVAC systems, building automation, and heating and ventilation installations. Is the protective sleeve robust enough for long-term operation? Yes, the protective sleeve is made of stainless steel and reliably protects the sensor.
Wall-Mounted Resistance Thermometer by JUMO with Pt100 and Analog Transmitter with 0 to 10 V and Measuring Range -40 to +80 °C JUMO Wall-Mounted Resistance Thermometer with Remote Protection Tube Protection Class IP65 The wall-mounted resistance thermometer is suitable for HVAC temperature measurements with direct voltage output. Equipped with Pt100 in a two-wire circuit, an integrated 0 to 10 V transmitter, and a measuring range of -40 to +80 °C, this version is suitable for wall-mounted measuring points where the temperature is measured at a point separated from the housing and transmitted directly as a voltage signal. For this purpose, the wall-mounted resistance thermometer is equipped with a remote protection tube. This makes the version particularly suitable for HVAC applications where direct integration into compatible control and regulation systems is required. Technical Data Version: Wall-mounted resistance thermometer with remote protection tube Measuring insert: 1 x Pt100 Circuit type: Two-wire circuit Transmitter: 1 x analog, output 0 to 10 V Measuring range: -40 to +80 °C Note: Measuring range only in combination with transmitter Protection class: IP65 Advantages and Technical Features of the Wall-Mounted Resistance Thermometer remote protection tube for more targeted temperature measurement direct 0 to 10 V signal for controllers and control systems well suited for wall-mounted measuring points with separated measuring locations IP65 protection class for increased housing protection requirements no additional external signal conversion required The remote protection tube makes this version especially interesting when the measuring point should not be located directly at the housing. This allows the temperature to be measured closer to the actual measuring location while the housing remains mounted separately on the wall. This is especially practical for applications where the housing position and measuring location are not identical. In addition, the version features an integrated 0 to 10 V transmitter. This means the temperature signal is available directly as a voltage signal and can be processed further without additional external signal conversion. Especially in building automation and HVAC applications, this is beneficial when controllers or control systems are designed for 0 to 10 V input signals. The associated measuring range is -40 to +80 °C and applies in combination with the transmitter. Typical Applications Wall-mounted measuring points in HVAC applications Building automation Heating, ventilation, and air conditioning systems Measuring points with a slightly remote measuring location Frequently Asked Questions What can I use this thermometer for? It is suitable for temperature monitoring in heating, ventilation, air conditioning, and building automation systems. Why does the thermometer have an extended protective sleeve? To allow the temperature to be measured closer to the actual point of interest rather than right at the housing. What temperature range is the thermometer suitable for? Depending on the specific model, the device is designed for temperature ranges of -30 to +60°C, -30 to +90°C, and -40 to +80°C. Is the thermometer suitable for humid environments? Yes, the housing is protected against dust and water jets in accordance with the IP65 rating. Where is this thermometer typically used? It is frequently used in HVAC systems, building automation, and heating and ventilation installations. Is the protective sleeve robust enough for long-term operation? Yes, the protective sleeve is made of stainless steel and reliably protects the sensor.
diraVIEW 116 digital indicator from JUMO for processing and visualization of process signals JUMO diraVIEW 116 – Digital indicator (48 × 48 mm) The JUMO diraVIEW 116 is a compact industrial digital indicator for flexible processing and visualization of process signals with integrated control and logic functions. It is particularly suitable for applications where measurement, evaluation, and simple control tasks are to be combined in a single device. The device is designed for universal use and can display and process measured values such as temperature, pressure, or other process variables. The display is provided via two easy-to-read 18-segment LCDs, complemented by status indicators for switching states and timer functions. The device features a universal analog input as well as several freely configurable inputs and outputs. This allows a wide variety of sensor signals to be processed and flexibly linked with relay, logic, or optional analog outputs. Selectors enable internal and external signals to be freely assigned, providing high adaptability for different applications. Optional USB, RS485, or Ethernet interfaces are available for communication. This allows the indicator to be configured locally as well as integrated into higher-level systems such as PLC or control systems. Additional functions such as limit value monitoring, timer, min./max. value storage, tare and hold functions, as well as mathematical and logical link functions significantly expand the range of applications and enable even complex control and monitoring tasks directly within the device. Advantages Universally applicable for various process signals Integrated limit value and alarm monitoring Easy integration into existing automation systems Reduces external control effort through integrated functions Fast commissioning through configuration via setup software Technical data Type: 701511/8-0000-23/000 Format: 48 × 48 mm Input: 1 × universal analog input Outputs: 2 × relays (normally open contact), 1 × digital input, 1 × DI/DO (logic output 0/14 V) Power supply: AC 110–240 V, 48–63 Hz Display: 2 × 18-segment LCD Communication: optional USB, RS485, Ethernet Functions: Min./max. value, hold, tare, timer, limit value monitoring Type addition: without Typical areas of application Mechanical and plant engineering Process and procedural engineering Temperature and pressure monitoring Automation and control technology General industrial measurement and display systems
Push-in resistance thermometer with straight connection cable, stainless steel protection tube Temperature measuring range: -50 ... +260 °C / Silicon Measuring insert: 1x Pt 100 in two-wire circuit Installation length: 45 mm Cable length: 2500 mm Tolerance class: Class B (standard) Thermowell diameter: 6 mm Wire end ferrules Extra code: with bend protection, cable shielded Available as single and dual resistance thermometers Available in straight and angled versions to meet different mounting requirements. Flexible connection cables Strain relief to protect against mechanical stress Meets SIL and PL qualification standards for maximum safety Optional kink protection Areas of application: - Laboratory technology- Climate cabinets- Solar systems- Heating, air conditioning, ventilation- Apparatus engineering The insertion resistance thermometer offers precise temperature measurement in both liquid and gaseous media. The wide range of variants makes it ideal for various applications in industrial environments. This thermometer ensures reliable performance in dry and damp rooms and enables accurate temperature measurements. The robust design and flexible configuration options ensure precise temperature monitoring.