MB A6K4 is a high capacity mixed bed ion exchange resin consisting of a mixture of strongly basic anion resin and a strongly acidic cation resin for direct water purification.The conductivity is about 0.06 µm/cm.Suitable for use in non-regenerable cartridges, high efficiency deionisation for silica removal and ultra pure water applications.Packed in 25 litre bagsPolymer matrix: gel polystyrene cross-linked with DVB.Ionic form, as supplied: H+ / OH-Physical shape and appearance: Spherical beadsSphericity: Min. 95%Particle size range (US Standard Screen): 1.25 - 0.315mm, wet.Particle size: +1.2mm < 5% ; -0.3mm < 1%Water retention H+: 45 - 50%Water retention OH-: 53 - 60%Shipping weight (approx.): 700-740 g/lMax. Temp. non-regenerative: 100°CMax. Temp. regenerative: 60°CpH-value range: 0-14Recommended operating conditions:Minimum bed depth should be 0.6m (24")Service flow rate should be 20-60 BV/hourProlonged exposure to strong oxidising agents such as chlorine, hydrogen peroxide and concentrated nitric acid will deteriorate the structural backbone of the resin and should be avoided.Mixture Resin:Anions: 60%Cations: 40%Purchase options:Single purchase - 25 ltr. (item no. 896495)1/2 pallet - 500 ltr. (Art.-No. 896496)1 pallet - 1050 ltr. (art.-no. 896497)
Proposed use: for the regeneration of water softenersComposition: evaporated salt (min. 99.9% NaCl)Dimensions / weight of tablet: ø25mm / 14gMoisture content: < 0.08Filling weight: 10kg per sackType of packaging: PE filmStorage description: store dry and well closedCertifications: ISO 9001, ISO 14001 and IFSStandard: The product complies with the following standards.EN 973:2009Products for the treatment of water intended for human consumption - Sodium chloride for regenerating ion exchange resins -Type AEN 16401:2013Products for the treatment of swimming pool water - Sodium chloride for use in electrochemical chlorine production plants - Type AEN 14805:2022Products for the treatment of water intended for human consumption - Sodium chloride for on-site electrochemical production of chlorine by membrane-free processes - Type 1EN 16370:2022Products for the treatment of water intended for human consumption - Sodium chloride for the on-site electrochemical production of chlorine by means of membrane cells - Quality 2Purchase options:Single purchase: 1x 10kg sack (Art.-No. 896467)Pallet purchase: 100x 10kg sacks (Art.-No. 896498)
Proposed use: for the regeneration of water softenersComposition: evaporated salt (min. 99.9% NaCl)Dimensions / weight of tablet: ø25mm / 14gMoisture content: < 0.08Filling weight: 25kg per sackType of packaging: PE filmStorage description: store dry and well closedCertifications: ISO 9001, ISO 14001 and IFSStandard: The product complies with the following standards...EN 973:2009Products for the treatment of water intended for human consumption - Sodium chloride for regenerating ion exchange resins -Type AEN 16401:2013Products for the treatment of swimming pool water - Sodium chloride for use in electrochemical chlorine production plants - Type AEN 14805:2022Products for the treatment of water intended for human consumption - Sodium chloride for on-site electrochemical production of chlorine by membrane-free processes - Type 1EN 16370:2022Products for the treatment of water intended for human consumption - Sodium chloride for the on-site electrochemical production of chlorine by means of membrane cells - Quality 2Purchase options:Single purchase: 1x 25kg sack (Art.-No. 896468)Pallet purchase: 40x 25kg sacks - 1000 kg (Art.-No. 896500)
Maximum capacity at 300 µS input water:
900 liters (6 ltr. MB resin filling)
Plastic cartridges variantsDK-VE 6 - demineralisation cartridge with hole in the head (capacity max. 900 litres at 300µS)DK-VE 10 - demineralisation cartridge with hole in the head (capacity max. 1,500 litres at 300µS)DK-VE 15 - demineralisation cartridge with hole in the head (capacity max. 2,250 litres at 300µS)DK-VE 20 - demineralisation cartridge with hole in the head (capacity max. 3,000 litres at 300µS)DK-VE 25 - demineralisation cartridge with hole in the head (capacity max. 3,750 litres at 300µS)DK-VE 30 - demineralisation cartridge with hole in the head (capacity max. 4,500 litres at 300µS)DK-VE 50 - demineralisation cartridge with hole in the head (capacity max. 7,500 ltr. at 300µS)
NeoTec Slave function module 1:
without
|
NeoTec Slave function module 2:
without
|
NeoTec Slave function module 3:
without
|
Number of parameters to be measured, up to:
4
Our 4- or 8- channel system allows the processing of up to four or eight measurement signals. For this purpose, 4-20 mA/ RS232 as well as Modbus RTU are available as signal inputs. Based on the received data a visualization as well as a trend display takes place. Through modular addition of optional modules (slaves) the realization of popular control concepts is possible.Advantages:Simple operation
Integration of the Testomat® device world
Integration into the existing control cabinet, alternatively we offer our NeoTecMaster® housingModular function range expandable by NeoTec slave modules (measure, control, control)Available as installation variant or structure variant
GENERAL DESCRIPTIONBecause the system is simple and efficient, water sterilisation by UV irradiation has developed strongly in recent years.The UV-C rays produced are considerably more intense than sunlight and for this reason are used to sterilise water. This technology is recognised in the field of disinfection for the removal of legionella, microbes, bacteria, viruses and protozoa, and this with respect for the environment. It is the ideal process for killing microorganisms in water. It makes water potable from a bacteriological point of view. This water is not considered drinking water until the chemical parameters are tested and deemed satisfactory.APPLICATIONS - ORIGIN OF THE WATER1. rainwater: UV treatment extends the range of applications and offers increased safety in use.2. well water: avoidance of possible contamination by pathogens.3. tap water: ensuring the quality of the water meets your expectations if deviations from your quality standards are detected.4. spring water, surface water: guaranteeing constant water quality that is impeccable from a bacteriological point of view.5. stored water in containers (caravan, boat, ...): Use of stored water for sanitary purposes.AREAS OF APPLICATION1. general nutrition, bath and shower2. cooking3. large-volume refrigerators4. cold water fountains5. aquarium6. cleaning food7. breeding: Chickens, rabbits, ducks, ... Drinking water without micro-organisms, especially without pathogensADVANTAGES:- Simple and quick installation- Completely physical disinfection by UV irradiation- Natural treatment of the water without additions and without the risk of overdosing with chemicals- No unpleasant taste or smell- Proven control of micro-organisms that are pathogenic for humans- No toxic by-products- Low maintenanceVariants:- UV system with 25W lampat 250J/m2 max. flow rate 28l/min.at 400J/m2 max. flow rate 16l/min.- UV system with 40W lampat 250J/m2 max. flow rate 35l/min.at 400J/m2 max. flow rate 21l/min.- UV system with 40W lamp, 25µm filter and activated carbon filterat 250J/m2 max. flow rate 43l/min.at 400J/m2 max. flow 27l/min.
GENERAL DESCRIPTIONBecause the system is simple and efficient, water sterilisation by UV irradiation has developed strongly in recent years.The UV-C rays produced are considerably more intense than sunlight and for this reason are used to sterilise water. This technology is recognised in the field of disinfection for the removal of legionella, microbes, bacteria, viruses and protozoa, and this with respect for the environment. It is the ideal process for killing microorganisms in water. It makes water potable from a bacteriological point of view. This water is not considered drinking water until the chemical parameters are tested and deemed satisfactory.APPLICATIONS - ORIGIN OF THE WATER1. rainwater: UV treatment extends the range of applications and offers increased safety in use.2. well water: avoidance of possible contamination by pathogens.3. tap water: ensuring the quality of the water meets your expectations if deviations from your quality standards are detected.4. spring water, surface water: guaranteeing constant water quality that is impeccable from a bacteriological point of view.5. stored water in containers (caravan, boat, ...): Use of stored water for sanitary purposes.AREAS OF APPLICATION1. general nutrition, bath and shower2. cooking3. large-volume refrigerators4. cold water fountains5. aquarium6. cleaning food7. breeding: Chickens, rabbits, ducks, ... Drinking water without micro-organisms, especially without pathogensADVANTAGES:- Simple and quick installation- Completely physical disinfection by UV irradiation- Natural treatment of the water without additions and without the risk of overdosing with chemicals- No unpleasant taste or smell- Proven control of micro-organisms that are pathogenic for humans- No toxic by-products- Low maintenanceVariants:- UV system with 25W lampat 250J/m2 max. flow rate 28l/min.at 400J/m2 max. flow rate 16l/min.- UV system with 40W lampat 250J/m2 max. flow rate 35l/min.at 400J/m2 max. flow rate 21l/min.- UV system with 40W lamp, 25µm filter and activated carbon filterat 250J/m2 max. flow rate 43l/min.at 400J/m2 max. flow 27l/min.
GENERAL DESCRIPTIONBecause the system is simple and efficient, water sterilisation by UV irradiation has developed strongly in recent years.The UV-C rays produced are considerably more intense than sunlight and for this reason are used to sterilise water. This technology is recognised in the field of disinfection for the removal of legionella, microbes, bacteria, viruses and protozoa, and this with respect for the environment. It is the ideal process for killing microorganisms in water. It makes water potable from a bacteriological point of view. This water is not considered drinking water until the chemical parameters are tested and deemed satisfactory.APPLICATIONS - ORIGIN OF THE WATER1. rainwater: UV treatment extends the range of applications and offers increased safety in use.2. well water: avoidance of possible contamination by pathogens.3. tap water: ensuring the quality of the water meets your expectations if deviations from your quality standards are detected.4. spring water, surface water: guaranteeing constant water quality that is impeccable from a bacteriological point of view.5. stored water in containers (caravan, boat, ...): Use of stored water for sanitary purposes.AREAS OF APPLICATION1. general nutrition, bath and shower2. cooking3. large-volume refrigerators4. cold water fountains5. aquarium6. cleaning food7. breeding: Chickens, rabbits, ducks, ... Drinking water without micro-organisms, especially without pathogensADVANTAGES:- Simple and quick installation- Completely physical disinfection by UV irradiation- Natural treatment of the water without additions and without the risk of overdosing with chemicals- No unpleasant taste or smell- Proven control of micro-organisms that are pathogenic for humans- No toxic by-products- Low maintenanceVariant:- UV system with 40W lamp, 25µm filter and activated carbon filterat 250J/m2 max. flow rate 43l/min.at 400J/m2 max. flow 27l/min.
GENERAL DESCRIPTIONBecause the system is simple and efficient, water sterilisation by UV irradiation has developed strongly in recent years.The UV-C rays produced are considerably more intense than sunlight and for this reason are used to sterilise water. This technology is recognised in the field of disinfection for the removal of legionella, microbes, bacteria, viruses and protozoa, and this with respect for the environment. It is the ideal process for killing microorganisms in water. It makes water potable from a bacteriological point of view. This water is not considered drinking water until the chemical parameters are tested and deemed satisfactory.APPLICATIONS - ORIGIN OF THE WATER1. rainwater: UV treatment extends the range of applications and offers increased safety in use.2. well water: avoidance of possible contamination by pathogens.3. tap water: ensuring the quality of the water meets your expectations if deviations from your quality standards are detected.4. spring water, surface water: guaranteeing constant water quality that is impeccable from a bacteriological point of view.5. stored water in containers (caravan, boat, ...): Use of stored water for sanitary purposes.AREAS OF APPLICATION1. general nutrition, bath and shower2. cooking3. large-volume refrigerators4. cold water fountains5. aquarium6. cleaning food7. breeding: Chickens, rabbits, ducks, ... Drinking water without micro-organisms, especially without pathogensADVANTAGES:- Simple and quick installation- Completely physical disinfection by UV irradiation- Natural treatment of the water without additions and without the risk of overdosing with chemicals- No unpleasant taste or smell- Proven control of micro-organisms that are pathogenic for humans- No toxic by-products- Low maintenanceVariant:- UV system with 25W lampat 250J/m2 max. flow rate 28l/min.at 400J/m2 max. flow rate 16l/min.
GENERAL DESCRIPTIONBecause the system is simple and efficient, water sterilisation by UV irradiation has developed strongly in recent years.The UV-C rays produced are considerably more intense than sunlight and for this reason are used to sterilise water. This technology is recognised in the field of disinfection for the removal of legionella, microbes, bacteria, viruses and protozoa, and this with respect for the environment. It is the ideal process for killing microorganisms in water. It makes water potable from a bacteriological point of view. This water is not considered drinking water until the chemical parameters are tested and deemed satisfactory.APPLICATIONS - ORIGIN OF THE WATER1. rainwater: UV treatment extends the range of applications and offers increased safety in use.2. well water: avoidance of possible contamination by pathogens.3. tap water: ensuring the quality of the water meets your expectations if deviations from your quality standards are detected.4. spring water, surface water: guaranteeing constant water quality that is impeccable from a bacteriological point of view.5. stored water in containers (caravan, boat, ...): Use of stored water for sanitary purposes.AREAS OF APPLICATION1. general nutrition, bath and shower2. cooking3. large-volume refrigerators4. cold water fountains5. aquarium6. cleaning food7. breeding: Chickens, rabbits, ducks, ... Drinking water without micro-organisms, especially without pathogensADVANTAGES:- Simple and quick installation- Completely physical disinfection by UV irradiation- Natural treatment of the water without additions and without the risk of overdosing with chemicals- No unpleasant taste or smell- Proven control of micro-organisms that are pathogenic for humans- No toxic by-products- Low maintenanceVariant:- UV system with 40W lampat 250J/m2 max. flow rate 35l/min.at 400J/m2 max. flow rate 21l/min.
High-quality conductivity meter with a 4-20mA signal output for forwarding the measured value to a higher-level control system, for example. The measurement is temperature compensated and therefore offers you an accurate measurement result. Also here we have the possibility to offer you an individual design regarding the connection, the LEDs including the measuring range up to a private label. Due to the acrylic glass cover used, the light of the LEDs is widely scattered and the current LED status can be seen from a distance in darker rooms. Quality Made in Germany.Our measuring device is also particularly suitable for mixed bed cartridge monitoring in the clinical environment.
Standard LED configuration (1 green LED, 1 red LED):<0.5 µS/cm = green>0.5 µS/cm to <1.0 µS/cm = green/red flashing >1 µS/cm = red
Technical data:Measuring range: 0 - 2 μS/cm / according to customer requirementsTemperature compensation: Linear 2.2 % / K, reference temperature 25°CAccuracy conductivity: +/- 5% of the maximum full scale valueAccuracy temperature: +-1.0 °CLimit value display: Optical via LEDAnalog output: 4-20 mA = 0-2 μS/cmConnection cable: 5 metrePower supply: 24 VDC +-10%Power consumption: < 2.5WScrew-in thread: 3/4" / according to customer requirementsHousing: POM (polyoxymethylene)Vision panel: PMMA (acrylic glass)Electrodes: stainless steel 1.457Dimensions: Diameter 60 mm x 60 mm (top) / 100 mm (total)Gaskets electrodes: EPDM, 28 x 3 mmGasket housing: EPDM, 50 x 2 mmApplication limits: P max: 6 bar; T max: 50 °CProtection class: IP 65*
measuring range:
0-5 μS/cm
|
potential-free relay contact:
with
Conductivity measuring instrument for measuring the electrical conductivity of aqueous solutions in the lower range by the integrated two-electrode screw-in measuring cell 3/4 inch without temperature compensation. Application examplesComplete desalination Reverse osmosis (2-stage)Mixed bed cartridges EDI (Electrodeionisation)Added value Operation at 9 V DC via supplied plug-in power supply unit 1 potential-free relay with switchable mode of operation of relay control Limit value display optically by means of LEDs Technical data Measuring range: 0 - 5 μS/cm Measuring accuracy: 2.5% of measuring range end value Resolution: 2 decimal places Limit value displays: Optical by means of LEDs, limit values adjustable between 0 and 100 % of the measuring range Limit value 1 preset to 1 μS/cm (relay contact) Limit value 2 preset to 0.5 μS/cm 1 potential-free relay contact, max. 2 A / 250 V AC, 60 W / 62.5 VA Power supply: 9 V DC via plug-in power supply unit 100 - 240 V AC Power consumption: approx. 1 W Protection class: IP 65 Housing: polycarbonate housing, 82 x 60 x 57 mm Connections: lateral connection for plug-in power supply and 1x relay output Measuring cell: ¾", PP, PN 6, Tmax. 60°C
The housing for holding the master or display unit as well as up to 6 function modules incl. optimized cable routing for connecting the individual components & PG glands for connecting external cables (e.g. for Ethernet, sensors and measurement technology). The advantages at a glance: Increase of the protection class to IP 66 and thus protection of the components against damage by environmental conditions. Optimized access for the cabling of the connected components.
The Testomat® 808 is a compact analyzer for the online measurement of water hardness according to the principle of " limit value monitoring by color change ". The Testomat® style="letter-spacing: 0px;"> 808 is a combination of the latest technologies based upon decades of international Testomat® experience.Applications of continuous residual hardness monitoring are for example:
Reverse osmosis plants
Boiler feed water supply
Soft water for commercial puposes
Pure water systems
Performance profile:Limit value indication (not exceeded or exceeded: green / red LED)
Modern indicator pump system
Automatic measuring process with low water consumption
Direct error and indicator quantity indication
Internal and external flushing of the measuring chamber by manual control
Control of an external rinsing valve
Three potential-free relays for:
External rinsing valve control
Limit value evaluation
External control and / or alarm processing
Safety check for 72 hours operation without supervision
Indicator quantities: 100 and 500 ml bottles
4 - 20 mA interface for defined status and error messages
RS 232 interface for firmware updates
Der Testomat® 808 SiO2 wurde für den Einsatz in Sterilisationen von Krankenhäusern konzipiert. Er erfüllt die Bedingungen der Norm EN 285:2006. Es handelt sich um ein Grenzwertmessgerät, das den Gehalt von SiO2 im Wasser automatisch überwacht. Sie haben die Wahl zwischen 10 Grenzwerten im Bereich von 0,3 bis 1,2 ppm.
Technische Daten
Netzanschluss: abhängig von Geräteausführung: 24V / 115V / 230V, 50 – 60 Hz
Geräteabsicherung: 230 – 240 V: T0,1 A; 115 V: T0,2 A; 24 V: T0,8 A
Netzabsicherung für Verbraucher: max. 4 A (N , L)
Leistungsaufnahme: max. 16 VA, ohne äußere Belastung
Schutzklasse: I
Schutzart: IP 54
Konformität: EN 61000-6-2, EN 61000-6-4, EN 61010-1
Umgebungstemperatur: 10 – 40 °C
Stromschnittstelle: Ausgabe definierter Werte (5, 8, 11, 14, 17, 20 mA) zur Ausgabe von Status- und Fehlermeldungen, max. Bürde 500 Ohm
Kontaktbelastung Relais: 230V / 4A AC ohmsche Last
Gewicht: 4350 g
Wasseranschluss
Betriebsdruck: Abhängig von Geräteausführung
0,3 – 1 bar / 0,3 x 105 bis 1 x 105 Pa
1 - 4 bar / 1 x 105 bis 4 x 105 Pa
Ab 4 bis 8 bar muss ein Druckminderer eingesetzt werden (Sonderzubehör)
Wasserzulauf: Lichtundurchlässiger Schlauch mit 6 mm Außendurchmesser/4 mm Innendurchmesser
Wasserablauf: Schlauch mit 6 mm Außendurchmesser/4 mm Innendurchmesser
Wassertemperatur: 10 bis 40 °C
The Testomat® 808 is a compact analyser for online measurement of water hardness according to the principle of "limit value monitoring with colour change" in the measuring range 0.02 - 5 ° dH (0.4 - 89 ppm). Applications of the continuous residual hardness monitoring are e.g.: Reverse osmosis systems, boiler feed water supply Soft water for commercial purposes, ultrapure water systems. In view of the fact that the Testomat® 808 is suitable for use in multi-parameter systems due to its 4-20mA signal output, we hereby offer you the Testomat® 808 in conjunction with the NeoTecMaster® Multicontroller, which was specially developed by our company, as a package solution at a preferential price. The 4-channel NeoTecMaster® Multicontroller included in this package enables the processing of up to four measurement signals. Via the 4-20mA NeoTec slave input module connected to the NeoTecMaster®, the data is transmitted to the NeoTecMaster® and used to display the measured value, the trend and the status messages on the 5-inch screen. In addition, the NeoTecMaster® has an RS232 interface as well as a Modbus RTU input, which you can use freely after brief technical consultation with us. (Pre-check whether your existing measurement technology to be integrated requires adjustments). The NeoTecMaster® can be systematically supplemented with further optional NeoTec modules (function / signal converter modules) as required. This allows the future realisation of further control concepts in a flexible way. Two modules which fundamentally extend the range of functions and are already included in the scope of delivery are our NeoTec slave relay module and the 4x 4-20mA input module. This allows you to add potential-free relay contacts to the overall system and to integrate and visualise further system technology such as sensors via the 4x 4-20mA input module. You can freely assign the relay contacts to the incoming measurement signals and thus, for example, implement simple limit value-related control concepts as well as output measurement value-related messages. Further advantages of the NeoTecMaster: Simple operation Integration of the Testomat® device world, here in connection with the Testomat® 808 Integration into the existing control cabinet, alternatively we offer our NeoTecMaster® enclosure Modular range of functions can be extended by NeoTec slave and signal converter modules (measurement, control, regulation) Available as built-in or surface-mounted variant Structured continuous data recording on the integrated SD card or optionally available SDHC card (2Gbyte) as a file in CSV format In addition, there are the proven functionalities of the Testomat® 808: Indication of limit value undershoot or overshoot: green / red LED Modern indicator pump system Automatic measuring sequence with low water consumption Direct error and indicator quantity display Internal and external flushing of the measuring chamber by manual control Control of an external flush valve Three potential-free relays for: External flush valve control Limit value evaluation External control and / or alarm processingSafety check for 72-hour operation without supervision Indicator quantities: 100 and 500 ml bottles 4 - 20 mA interface for defined status and error messages RS 232 interface for firmware updates General informationWater connection and operating pressure: Depending on unit version: 0.3 - 1 bar / 0.3 x 105 to 4 x 105 Pa 1 - 4 bar / 1 x 105 to 4 x 105 Pa (from 4 to 8 bar, a pressure reducer must be used (special accessory)) Water inlet: opaque hose with 6 mm outer diameter/4 mm inner diameter Water outlet: hose with 6 mm outer diameter/4 mm inner diameter Water temperature: 10 to 40 °CFrom 4 bar, a separately available pressure reducer must be used. Please use only the indicators approved for Testomat® 808 / Testomat® BOB!Optional accessories: NeoTecMaster unit hood
The Testomat® ECO / EVO automatically determines the water hardness by means of titration. The device is suitable for controlling the water quality of water treatment plants, drinking water systems, industrial boilers and for monitoring process water. Approved for boiler houses | component identification no.: TÜV. WÜH. 21-025 | VdTÜV bulletin water monitoring device 100 and UL-TÜV certified.The Testomat® style="letter-spacing: 0px;"> EVO TH convinces with new functionalities:Optical water detection when filling the measuring chamber
BOB operation (operation without constant supervision)Import and export of settings (basic programming) with selectable file nameLogging of measurement data and messages / alarms using an integrated SD or optional SDHC card (2GByte)
Firmware update via SD card
LCD graphic display
Multilingual menu with easy switching (internal programming is retained)
Integrated self-test with continuous monitoring
External clear / acknowledge input
Free programmable password
Automatic bleeding of the indicator line
Doors can be changed individually
Range monitoring (fall below limit value1 / exceed limit value 2)
Permitted number of lack of water, freely programmable (for systems with temporarily low water pressure)[#mspacer#]Performance profile:High-precision titration using a piston dosing pump
Analogue output 0/4 - 20 mA
Serial RS232 interface for transfer of measurement data and messages/alarmsProgrammable hardness unit in ° dH, ° f, ppm CaCO3, mmol / l
2 independent limits with adjustable switching functions as well as switching option in accordance with an adjustable number of negativeanalyzes
Analysis initiation:
automatic interval operation (0-99 minutes)
depending on quantity via contact water meter
Indicator quantities: 100 und 500 ml bottles
The Testomat® EVO TH is supplied without a power switch. This is done to comply with the DIN EN 61010-1 safety standard for measuring, control and laboratory equipment. Of course, an external mains switch will be made available to you as a customer for purchase. You can order this from us as a disconnector under article no. 850925, "external cam switch with protection class IP65".