Electrodes and sensors are used in industry for a variety of applications to measure and monitor physical, chemical and biological processes.
The electrodes and sensors are generally used to measure and control certain parameters. They are used to increase efficiency and improve the quality of production processes and to ensure safety in the workplace.
Overall, electrodes and sensors help to make industrial processes more efficient, safer and of higher quality. They enable the measurement and control of important parameters in order to increase the effectiveness and profitability of production processes.
Some examples of applications are
- pH sensors and electrodes
- Oxygen sensors and electrodes
- Conductivity sensors and electrodes
- Temperature sensors and electrodes
- Biological sensors and electrodes
- Water Analyzers
- Liquid chemistry
- Controls
- Electrodes and sensors
- Hand-held measuring instruments and analysis cases
- Laboratory Benchtop Meters
- NeoTec World
- Permeate
- Clinical Solutions
- Seminars & Webinars
- Ozone and UV technology
- Dosing pumps
- Gas Measuring Instruments
- Hygiene and Disinfection
- Water Meters
- Accessories
- Blog
Filter products
JUMO miro TRON - electronic thermostat with PID two-point controller option Typ: 701080/0-01-23-30/000 Input: 1 resistance thermometer Pt100, Pt1000 in two-wire circuit, 1 digital input Output: 1 relay (changeover contact AC 250 V, 10 A) and 1 relay (NO contact AC 250 V, 5 A), resistive load Power supply: DC 12 bis 24 V +15/-15% Version: Standard version Extra code: without The electronic thermostat is used as a heating or cooling thermostat, but can be optionally extended with a PID two-point controller option. The device offers user-friendly operation, characterised by a clear structure and supporting texts in German, English, French and Spanish. Process values, texts and parameters are displayed on two 18-segment LCD displays. Additional display elements provide information on the switching positions of the outputs, the status of the timer and the temperature unit used. PCB terminals with push-in technology enable quick electrical installation. Operation, parameterisation and configuration are carried out via a membrane keypad with four buttons. PID two-point controller (optional)If the PID two-point controller option is selected, various controller structures are available, including P, I, PH, PI and PID, which also enable self-optimisation. In addition, the setup programme offers a start-up function and a display of the online parameters. Inputs and outputsThe required analogue input can be selected when ordering: Resistance thermometer Thermocouple Current (4 to 20 mA) Voltage (0 to 10 V) There is also a digital input for connecting a potential-free contact (not for resistance thermometers in three-wire circuit). Depending on the device type, the following combinations are available as outputs: 2 relays (1 changeover contact, 1 NO contact), or 1 relay (NO contact) and 1 digital output DC 0/14 V, or 4 relays (NO contact). USB device interfaceThe device has a Micro-B socket, which is intended for connection to a PC for configuration with the setup programme. No separate power supply is required during configuration via the USB interface (USB-powered). Electrical connectionThe electrical connection is made in a time-saving manner using spring-loaded terminals (push-in technology) Self-optimisationSelf-optimisation (oscillation method) makes it possible even for users with no knowledge of control technology to adapt the controller to the controlled system. The reactions of the controlled system to changes in the manipulated variable are analysed and certain controller parameters are calculated. Limit value monitoringThe device has three limit value monitors, each of which offers eight configurable alarm functions. Any analogue signal is selected from a selector as the value to be monitored. The limit values can be defined either as an absolute value or as a different analogue signal. Additional functions: On/off delay Wiper function Alarm suppression during the switch-on phase or when parameters are changed Alarm latching Latching with acknowledgement are available. Comprehensive alarm and limit value functions can be realised with limit value monitoring. TimerOnce the timer has been activated, a signal is emitted for the preset runtime, which can be inverted. The timer can also be started after a lead time has elapsed or a tolerance limit has been reached. After the timer has elapsed, an end signal can be generated that is either limited in time or can be deactivated by acknowledgement. The timer makes it possible, for example, to realise a time-controlled setpoint changeover. Service counterThe service counter can either count the number of switching operations of a binary signal or measure its switch-on duration. As soon as the adjustable limit value is reached, a binary signal is activated that must be acknowledged. An operating hours counter is also available, which records the operating time of the device. Setup programmeThe optional setup programme allows the user to configure the device easily and conveniently via a PC. With this programme, data can be created, edited, transferred to the device and read out from there. It also offers a recording function for commissioning (start-up). Customer-specific linearisationIndividual linearisation according to customer requirements makes it possible to use sensor signals with special characteristics. Programming is carried out in the setup programme either using your value table with up to 40 value pairs or using a formula (4th order polynomial)
JUMO miro TRON - electronic thermostat with PID two-point controller option Typ: 701080/0-04-23-02/000 Input: 1 thermocouple and 1 digital input Output: 1 relay (changeover contact AC 250 V, 10 A) and 1 relay (NO contact AC 250 V, 5 A), resistive load Power supply: AC 230 V+10/-15%, 48 bis 63 Hz Version: Standard version Extra code: without The electronic thermostat is used as a heating or cooling thermostat, but can be optionally extended with a PID two-point controller option. The device offers user-friendly operation, characterised by a clear structure and supporting texts in German, English, French and Spanish. Process values, texts and parameters are displayed on two 18-segment LCD displays. Additional display elements provide information on the switching positions of the outputs, the status of the timer and the temperature unit used. PCB terminals with push-in technology enable quick electrical installation. Operation, parameterisation and configuration are carried out via a membrane keypad with four buttons. PID two-point controller (optional)If the PID two-point controller option is selected, various controller structures are available, including P, I, PH, PI and PID, which also enable self-optimisation. In addition, the setup programme offers a start-up function and a display of the online parameters. Inputs and outputsThe required analogue input can be selected when ordering: Resistance thermometer Thermocouple Current (4 to 20 mA) Voltage (0 to 10 V) There is also a digital input for connecting a potential-free contact (not for resistance thermometers in three-wire circuit). Depending on the device type, the following combinations are available as outputs: 2 relays (1 changeover contact, 1 NO contact), or 1 relay (NO contact) and 1 digital output DC 0/14 V, or 4 relays (NO contact). USB device interfaceThe device has a Micro-B socket, which is intended for connection to a PC for configuration with the setup programme. No separate power supply is required during configuration via the USB interface (USB-powered). Electrical connectionThe electrical connection is made in a time-saving manner using spring-loaded terminals (push-in technology) Self-optimisationSelf-optimisation (oscillation method) makes it possible even for users with no knowledge of control technology to adapt the controller to the controlled system. The reactions of the controlled system to changes in the manipulated variable are analysed and certain controller parameters are calculated. Limit value monitoringThe device has three limit value monitors, each of which offers eight configurable alarm functions. Any analogue signal is selected from a selector as the value to be monitored. The limit values can be defined either as an absolute value or as a different analogue signal. Additional functions: On/off delay Wiper function Alarm suppression during the switch-on phase or when parameters are changed Alarm latching Latching with acknowledgement are available. Comprehensive alarm and limit value functions can be realised with limit value monitoring. TimerOnce the timer has been activated, a signal is emitted for the preset runtime, which can be inverted. The timer can also be started after a lead time has elapsed or a tolerance limit has been reached. After the timer has elapsed, an end signal can be generated that is either limited in time or can be deactivated by acknowledgement. The timer makes it possible, for example, to realise a time-controlled setpoint changeover. Service counterThe service counter can either count the number of switching operations of a binary signal or measure its switch-on duration. As soon as the adjustable limit value is reached, a binary signal is activated that must be acknowledged. An operating hours counter is also available, which records the operating time of the device. Setup programmeThe optional setup programme allows the user to configure the device easily and conveniently via a PC. With this programme, data can be created, edited, transferred to the device and read out from there. It also offers a recording function for commissioning (start-up). Customer-specific linearisationIndividual linearisation according to customer requirements makes it possible to use sensor signals with special characteristics. Programming is carried out in the setup programme either using your value table with up to 40 value pairs or using a formula (4th order polynomial)
JUMO miro TRON - electronic thermostat with PID two-point controller option Typ: 701080/0-05-23-02/000 Input: 0(4) to 20 mA and 1 digital input Output: 1 relay (changeover contact AC 250 V, 10 A) and 1 relay (NO contact AC 250 V, 5 A), resistive load Power supply: AC 230 V+10/-15%, 48 bis 63 Hz Version: Standard version Extra code: without The electronic thermostat is used as a heating or cooling thermostat, but can be optionally extended with a PID two-point controller option. The device offers user-friendly operation, characterised by a clear structure and supporting texts in German, English, French and Spanish. Process values, texts and parameters are displayed on two 18-segment LCD displays. Additional display elements provide information on the switching positions of the outputs, the status of the timer and the temperature unit used. PCB terminals with push-in technology enable quick electrical installation. Operation, parameterisation and configuration are carried out via a membrane keypad with four buttons. PID two-point controller (optional)If the PID two-point controller option is selected, various controller structures are available, including P, I, PH, PI and PID, which also enable self-optimisation. In addition, the setup programme offers a start-up function and a display of the online parameters. Inputs and outputsThe required analogue input can be selected when ordering: Resistance thermometer Thermocouple Current (4 to 20 mA) Voltage (0 to 10 V) There is also a digital input for connecting a potential-free contact (not for resistance thermometers in three-wire circuit). Depending on the device type, the following combinations are available as outputs: 2 relays (1 changeover contact, 1 NO contact), or 1 relay (NO contact) and 1 digital output DC 0/14 V, or 4 relays (NO contact). USB device interfaceThe device has a Micro-B socket, which is intended for connection to a PC for configuration with the setup programme. No separate power supply is required during configuration via the USB interface (USB-powered). Electrical connectionThe electrical connection is made in a time-saving manner using spring-loaded terminals (push-in technology) Self-optimisationSelf-optimisation (oscillation method) makes it possible even for users with no knowledge of control technology to adapt the controller to the controlled system. The reactions of the controlled system to changes in the manipulated variable are analysed and certain controller parameters are calculated. Limit value monitoringThe device has three limit value monitors, each of which offers eight configurable alarm functions. Any analogue signal is selected from a selector as the value to be monitored. The limit values can be defined either as an absolute value or as a different analogue signal. Additional functions: On/off delay Wiper function Alarm suppression during the switch-on phase or when parameters are changed Alarm latching Latching with acknowledgement are available. Comprehensive alarm and limit value functions can be realised with limit value monitoring. TimerOnce the timer has been activated, a signal is emitted for the preset runtime, which can be inverted. The timer can also be started after a lead time has elapsed or a tolerance limit has been reached. After the timer has elapsed, an end signal can be generated that is either limited in time or can be deactivated by acknowledgement. The timer makes it possible, for example, to realise a time-controlled setpoint changeover. Service counterThe service counter can either count the number of switching operations of a binary signal or measure its switch-on duration. As soon as the adjustable limit value is reached, a binary signal is activated that must be acknowledged. An operating hours counter is also available, which records the operating time of the device. Setup programmeThe optional setup programme allows the user to configure the device easily and conveniently via a PC. With this programme, data can be created, edited, transferred to the device and read out from there. It also offers a recording function for commissioning (start-up). Customer-specific linearisationIndividual linearisation according to customer requirements makes it possible to use sensor signals with special characteristics. Programming is carried out in the setup programme either using your value table with up to 40 value pairs or using a formula (4th order polynomial)
JUMO miro VIEW - smart digital indicator with limit value monitoring Typ: 701580/0-01-23-02 Input: 1 resistance thermometer Pt100, Pt1000 in two-wire circuit, 1 digital input Output: 1 relay (changeover contact AC 250 V, 10 A) and 1 relay (make contact AC 250 V, 5 A) resistive load Power supply: AC 230 V +10/-15 %, 48 to 63 Hz The smart digital indicator is used to electronically display various process variables. The device records the process variables via resistance thermometer, thermocouple, current 0(4) to 20 mA or voltage 0 to 10 V. Other functions include limit value monitoring, min/max value storage, hold function and tare function. The device can be supplied either with 2 relays or with 1 relay and 1 digital output (DC0/14 V). It is characterised by user-friendly, clear operation in German, English, French and Spanish. Process values, texts and parameters are displayed on two 18-segment LCD displays. Additional display elements provide information about Switching positions of the outputs Status of the timer Temperature unit PCB terminals with push-in technology enable quick electrical installation. Operation, parameterisation and configuration are carried out via a membrane keypad with four buttons. Display functionIn addition to the conventional display of the measured value, the device offers additional functions such as Display of min/max values Hold function to hold the current measured value Tare function for weighing applications Some of these functions can be configured using the membrane keypad on the front. Inputs and outputsThe required analogue input can be selected when ordering: Resistance thermometer Thermocouple Current (4 to 20 mA) Voltage (0 to 10 V) There is also a digital input for connecting a potential-free contact (not for resistance thermometers in three-wire circuit). Depending on the device type, the following combinations are available as outputs: 2 relays (1 changeover contact, 1 NO contact), or 1 relay (NO contact) and 1 digital output DC 0/14 V, or 4 relays (NO contact). USB device interfaceThe device has a Micro-B socket that is intended for connection to a PC for configuration with the setup programme. No separate power supply is required during configuration via the USB interface (USB-powered). Electrical connectionThe electrical connection is made using time-saving spring-loaded terminals (push-in technology) Limit value monitoringThe device has three limit value monitors, each of which offers two configurable alarm functions. Any analogue signal is selected from a selector as the value to be monitored. The limit values can be defined either as an absolute value or as a different analogue signal. Additional functions: On/off delay Wiper function Alarm suppression during the switch-on phase or when parameters are changed Alarm latching Latching with acknowledgement are available. Comprehensive alarm and limit value functions can be realised with limit value monitoring. TimerAfter the timer is activated, a signal is output for the preset runtime, which can be inverted. The timer can also be started after a lead time has elapsed or a tolerance limit has been reached.The service counter is used either to count the switching frequency of a binary signal or to determine its switch-on duration. As soon as the adjustable limit value is reached, a binary signal is activated and must be acknowledged. An operating hours counter is also available, which records the operating time of the device. Setup programmeThe optional setup programme enables the user to configure the device easily and conveniently via a PC. With this programme, data can be created, edited, transferred to the device and read out from there. It also offers a recording function for commissioning (start-up). Customer-specific linearisationIndividual linearisation according to customer requirements makes it possible to use sensor signals with special characteristics. Programming is carried out in the setup programme either using your value table with up to 40 value pairs or using a formula (4th order polynomial)
JUMO miro VIEW - smart digital indicator with limit value monitoring Typ: 701580/0-01-23-30 Input: 1 resistance thermometer Pt100, Pt1000 in two-wire circuit, 1 digital input Output: 1 relay (changeover contact AC 250 V, 10 A) and 1 relay (make contact AC 250 V, 5 A) resistive load Power supply: DC 12 bis 24 V +15/-15% The smart digital indicator is used to electronically display various process variables. The device records the process variables via resistance thermometer, thermocouple, current 0(4) to 20 mA or voltage 0 to 10 V. Other functions include limit value monitoring, min/max value storage, hold function and tare function. The device can be supplied either with 2 relays or with 1 relay and 1 digital output (DC0/14 V). It is characterised by user-friendly, clear operation in German, English, French and Spanish. Process values, texts and parameters are displayed on two 18-segment LCD displays. Additional display elements provide information about Switching positions of the outputs Status of the timer Temperature unit PCB terminals with push-in technology enable quick electrical installation. Operation, parameterisation and configuration are carried out via a membrane keypad with four buttons. Display functionIn addition to the conventional display of the measured value, the device offers additional functions such as Display of min/max values Hold function to hold the current measured value Tare function for weighing applications Some of these functions can be configured using the membrane keypad on the front. Inputs and outputsThe required analogue input can be selected when ordering: Resistance thermometer Thermocouple Current (4 to 20 mA) Voltage (0 to 10 V) There is also a digital input for connecting a potential-free contact (not for resistance thermometers in three-wire circuit). Depending on the device type, the following combinations are available as outputs: 2 relays (1 changeover contact, 1 NO contact), or 1 relay (NO contact) and 1 digital output DC 0/14 V, or 4 relays (NO contact). USB device interfaceThe device has a Micro-B socket that is intended for connection to a PC for configuration with the setup programme. No separate power supply is required during configuration via the USB interface (USB-powered). Electrical connectionThe electrical connection is made using time-saving spring-loaded terminals (push-in technology) Limit value monitoringThe device has three limit value monitors, each of which offers two configurable alarm functions. Any analogue signal is selected from a selector as the value to be monitored. The limit values can be defined either as an absolute value or as a different analogue signal. Additional functions: On/off delay Wiper function Alarm suppression during the switch-on phase or when parameters are changed Alarm latching Latching with acknowledgement are available. Comprehensive alarm and limit value functions can be realised with limit value monitoring. TimerAfter the timer is activated, a signal is output for the preset runtime, which can be inverted. The timer can also be started after a lead time has elapsed or a tolerance limit has been reached.The service counter is used either to count the switching frequency of a binary signal or to determine its switch-on duration. As soon as the adjustable limit value is reached, a binary signal is activated and must be acknowledged. An operating hours counter is also available, which records the operating time of the device. Setup programmeThe optional setup programme enables the user to configure the device easily and conveniently via a PC. With this programme, data can be created, edited, transferred to the device and read out from there. It also offers a recording function for commissioning (start-up). Customer-specific linearisationIndividual linearisation according to customer requirements makes it possible to use sensor signals with special characteristics. Programming is carried out in the setup programme either using your value table with up to 40 value pairs or using a formula (4th order polynomial)
JUMO miro VIEW - smart digital indicator with limit value monitoring Typ: 701580/0-04-23-02 Input: 1 Thermoelement und 1 Digitaleingang Output: 1 relay (changeover contact AC 250 V, 10 A) and 1 relay (make contact AC 250 V, 5 A) resistive load Power supply: AC 230 V +10/-15 %, 48 to 63 Hz The smart digital indicator is used to electronically display various process variables. The device records the process variables via resistance thermometer, thermocouple, current 0(4) to 20 mA or voltage 0 to 10 V. Other functions include limit value monitoring, min/max value storage, hold function and tare function. The device can be supplied either with 2 relays or with 1 relay and 1 digital output (DC0/14 V). It is characterised by user-friendly, clear operation in German, English, French and Spanish. Process values, texts and parameters are displayed on two 18-segment LCD displays. Additional display elements provide information about Switching positions of the outputs Status of the timer Temperature unit PCB terminals with push-in technology enable quick electrical installation. Operation, parameterisation and configuration are carried out via a membrane keypad with four buttons. Display functionIn addition to the conventional display of the measured value, the device offers additional functions such as Display of min/max values Hold function to hold the current measured value Tare function for weighing applications Some of these functions can be configured using the membrane keypad on the front. Inputs and outputsThe required analogue input can be selected when ordering: Resistance thermometer Thermocouple Current (4 to 20 mA) Voltage (0 to 10 V) There is also a digital input for connecting a potential-free contact (not for resistance thermometers in three-wire circuit). Depending on the device type, the following combinations are available as outputs: 2 relays (1 changeover contact, 1 NO contact), or 1 relay (NO contact) and 1 digital output DC 0/14 V, or 4 relays (NO contact). USB device interfaceThe device has a Micro-B socket that is intended for connection to a PC for configuration with the setup programme. No separate power supply is required during configuration via the USB interface (USB-powered). Electrical connectionThe electrical connection is made using time-saving spring-loaded terminals (push-in technology) Limit value monitoringThe device has three limit value monitors, each of which offers two configurable alarm functions. Any analogue signal is selected from a selector as the value to be monitored. The limit values can be defined either as an absolute value or as a different analogue signal. Additional functions: On/off delay Wiper function Alarm suppression during the switch-on phase or when parameters are changed Alarm latching Latching with acknowledgement are available. Comprehensive alarm and limit value functions can be realised with limit value monitoring. TimerAfter the timer is activated, a signal is output for the preset runtime, which can be inverted. The timer can also be started after a lead time has elapsed or a tolerance limit has been reached.The service counter is used either to count the switching frequency of a binary signal or to determine its switch-on duration. As soon as the adjustable limit value is reached, a binary signal is activated and must be acknowledged. An operating hours counter is also available, which records the operating time of the device. Setup programmeThe optional setup programme enables the user to configure the device easily and conveniently via a PC. With this programme, data can be created, edited, transferred to the device and read out from there. It also offers a recording function for commissioning (start-up). Customer-specific linearisationIndividual linearisation according to customer requirements makes it possible to use sensor signals with special characteristics. Programming is carried out in the setup programme either using your value table with up to 40 value pairs or using a formula (4th order polynomial)
JUMO miro VIEW - smart digital indicator with limit value monitoring Typ: 701580/0-05-23-02 Input: 0(4) to 20mA and 1 digital input Output: 1 relay (changeover contact AC 250 V, 10 A) and 1 relay (make contact AC 250 V, 5 A) resistive load Power supply: AC 230 V +10/-15 %, 48 to 63 Hz The smart digital indicator is used to electronically display various process variables. The device records the process variables via resistance thermometer, thermocouple, current 0(4) to 20 mA or voltage 0 to 10 V. Other functions include limit value monitoring, min/max value storage, hold function and tare function. The device can be supplied either with 2 relays or with 1 relay and 1 digital output (DC0/14 V). It is characterised by user-friendly, clear operation in German, English, French and Spanish. Process values, texts and parameters are displayed on two 18-segment LCD displays. Additional display elements provide information about Switching positions of the outputs Status of the timer Temperature unit PCB terminals with push-in technology enable quick electrical installation. Operation, parameterisation and configuration are carried out via a membrane keypad with four buttons. Display functionIn addition to the conventional display of the measured value, the device offers additional functions such as Display of min/max values Hold function to hold the current measured value Tare function for weighing applications Some of these functions can be configured using the membrane keypad on the front. Inputs and outputsThe required analogue input can be selected when ordering: Resistance thermometer Thermocouple Current (4 to 20 mA) Voltage (0 to 10 V) There is also a digital input for connecting a potential-free contact (not for resistance thermometers in three-wire circuit). Depending on the device type, the following combinations are available as outputs: 2 relays (1 changeover contact, 1 NO contact), or 1 relay (NO contact) and 1 digital output DC 0/14 V, or 4 relays (NO contact). USB device interfaceThe device has a Micro-B socket that is intended for connection to a PC for configuration with the setup programme. No separate power supply is required during configuration via the USB interface (USB-powered). Electrical connectionThe electrical connection is made using time-saving spring-loaded terminals (push-in technology) Limit value monitoringThe device has three limit value monitors, each of which offers two configurable alarm functions. Any analogue signal is selected from a selector as the value to be monitored. The limit values can be defined either as an absolute value or as a different analogue signal. Additional functions: On/off delay Wiper function Alarm suppression during the switch-on phase or when parameters are changed Alarm latching Latching with acknowledgement are available. Comprehensive alarm and limit value functions can be realised with limit value monitoring. TimerAfter the timer is activated, a signal is output for the preset runtime, which can be inverted. The timer can also be started after a lead time has elapsed or a tolerance limit has been reached.The service counter is used either to count the switching frequency of a binary signal or to determine its switch-on duration. As soon as the adjustable limit value is reached, a binary signal is activated and must be acknowledged. An operating hours counter is also available, which records the operating time of the device. Setup programmeThe optional setup programme enables the user to configure the device easily and conveniently via a PC. With this programme, data can be created, edited, transferred to the device and read out from there. It also offers a recording function for commissioning (start-up). Customer-specific linearisationIndividual linearisation according to customer requirements makes it possible to use sensor signals with special characteristics. Programming is carried out in the setup programme either using your value table with up to 40 value pairs or using a formula (4th order polynomial)
Room, outdoor and duct resistance thermometers Typ: 902520/15-361-1003-1/000 Measuring range from -50 to +90°C Measuring insert 1x temperature sensor Pt100 in two-wire circuit Transmitter: without Protection class IP65 Suitable for use in air conditioning technology Room, outdoor and duct resistance thermometers are designed for air conditioning technology and are mainly used for temperature measurement in rooms, air ducts and outdoors. Various plastic device versions with different degrees of protection are available for the respective measuring task. A Pt100 temperature sensor in accordance with DIN EN 60751 class B in a two-wire circuit is installed as standard, but variants with Pt500, Pt1000, Ni1000 and various NTC sensors are also possible. The connection terminals allow optional continuation in three- and four-wire circuits. An integrated measuring transducer can also be selected as an option.
Room, outdoor and duct resistance thermometers Typ: 902520/15-361-1005-1/000 Measuring range from -50 to +90°C Measuring insert 1x temperature sensor Pt1000 in two-wire circuit Transmitter: without Protection class IP65 Suitable for use in air conditioning technology Room, outdoor and duct resistance thermometers are designed for air conditioning technology and are mainly used for temperature measurement in rooms, air ducts and outdoors. Various plastic device versions with different degrees of protection are available for the respective measuring task. A Pt100 temperature sensor in accordance with DIN EN 60751 class B in a two-wire circuit is installed as standard, but variants with Pt500, Pt1000, Ni1000 and various NTC sensors are also possible. The connection terminals allow optional continuation in three- and four-wire circuits. An integrated measuring transducer can also be selected as an option.
Room, outdoor and duct resistance thermometers Typ: 902520/15-361-1003-1/903, Measuring range from -50 to +90°C Measuring insert 1x temperature sensor Pt100 in two-wire circuit Transmitter: without Cable gland (IP65) Protection class IP65 Suitable for use in air conditioning technology Room, outdoor and duct resistance thermometers are designed for air conditioning technology and are mainly used for temperature measurement in rooms, air ducts and outdoors. Various plastic device versions with different degrees of protection are available for the respective measuring task. A Pt100 temperature sensor in accordance with DIN EN 60751 class B in a two-wire circuit is installed as standard, but variants with Pt500, Pt1000, Ni1000 and various NTC sensors are also possible. The connection terminals allow optional continuation in three- and four-wire circuits. An integrated measuring transducer can also be selected as an option.
Room, outdoor and duct resistance thermometers Typ: 902520/15-361-1005-1/903 Measuring range from -50 to +90°C Measuring insert 1x temperature sensor Pt1000 in two-wire circuit Transmitter: without Cable gland (IP65) Protection class IP65 Suitable for use in air conditioning technology Room, outdoor and duct resistance thermometers are designed for air conditioning technology and are mainly used for temperature measurement in rooms, air ducts and outdoors. Various plastic device versions with different degrees of protection are available for the respective measuring task. A Pt100 temperature sensor in accordance with DIN EN 60751 class B in a two-wire circuit is installed as standard, but variants with Pt500, Pt1000, Ni1000 and various NTC sensors are also possible. The connection terminals allow optional continuation in three- and four-wire circuits. An integrated measuring transducer can also be selected as an option.
Room, outdoor and duct resistance thermometers Typ: 902520/11-635-1003-1/000 Measuring range from -20 to +80°C Measuring insert 1x temperature sensor Pt100 in two-wire circuit Transmitter: without Protection class IP54 Suitable for use in air conditioning technology Room, outdoor and duct resistance thermometers are designed for air conditioning technology and are mainly used for temperature measurement in rooms, air ducts and outdoors. Various plastic device versions with different degrees of protection are available for the respective measuring task. A Pt100 temperature sensor in accordance with DIN EN 60751 class B in a two-wire circuit is installed as standard, but variants with Pt500, Pt1000, Ni1000 and various NTC sensors are also possible. The connection terminals allow optional continuation in three- and four-wire circuits. An integrated measuring transducer can also be selected as an option.
Room, outdoor and duct resistance thermometers Typ: 902520/10-572-1001-1/00 Measuring range from -30 to +80°C Measuring insert 1x temperature sensor Pt100 in three-wire circuit Transmitter: without Protection class IP20 Suitabel for use in air conditioning technology Room, outdoor and duct resistance thermometers are designed for air conditioning technology and are mainly used for temperature measurement in rooms, air ducts and outdoors. Various plastic device versions with different degrees of protection are available for the respective measuring task. A Pt100 temperature sensor in accordance with DIN EN 60751 Class B in a two-wire circuit is installed as standard, but variants with Pt500, Pt1000, Ni1000 and various NTC sensors are also possible. The connection terminals allow optional continuation in three- and four-wire circuits. An integrated measuring transducer can also be selected as an option.
Room, outdoor and duct resistance thermometers Typ: 902520/10-572-1005-1/000 Measuring range from -30 to +80°C Measuring insert 1x temperature sensor Pt1000 in two-wire circuit Transmitter: without Protection class IP20 Suitabel for use in air conditioning technology Room, outdoor and duct resistance thermometers are designed for air conditioning technology and are mainly used for temperature measurement in rooms, air ducts and outdoors. Various plastic device versions with different degrees of protection are available for the respective measuring task. A Pt100 temperature sensor in accordance with DIN EN 60751 Class B in a two-wire circuit is installed as standard, but variants with Pt500, Pt1000, Ni1000 and various NTC sensors are also possible. The connection terminals allow optional continuation in three- and four-wire circuits. An integrated measuring transducer can also be selected as an option.
Room, outdoor and duct resistance thermometers Typ: 902520/10-803-1003-1/330,(0..40°C) Measuring range from 0 to +40°C (Measuring range only in conjunction with transmitter) Measuring insert 1x temperature sensor Pt100 in two-wire circuit Transmitter: 1x Analog transmitter, output 4 to 20 mA (only in conjunction with 1x Pt100 t-w) (0-40°C) Protection class IP20 Suitabel for use in air conditioning technology Room, outdoor and duct resistance thermometers are designed for air conditioning technology and are mainly used for temperature measurement in rooms, air ducts and outdoors. Various plastic device versions with different degrees of protection are available for the respective measuring task. A Pt100 temperature sensor in accordance with DIN EN 60751 Class B in a two-wire circuit is installed as standard, but variants with Pt500, Pt1000, Ni1000 and various NTC sensors are also possible. The connection terminals allow optional continuation in three- and four-wire circuits. An integrated measuring transducer can also be selected as an option.
Room, outdoor and duct resistance thermometers Typ: 902520/10-807-1003-1/330,(0..60°C) Measuring range from 0 to +60°C (Measuring range only in conjunction with transmitter) Measuring insert 1x temperature sensor Pt100 in two-wire circuit Transmitter: 1x analog transmitter, output 4 to 20 mA (only in conjunction with 1x Pt100 t-w) (0-60°C) Protection class IP20 Suitabel for use in air conditioning technology Room, outdoor and duct resistance thermometers are designed for air conditioning technology and are mainly used for temperature measurement in rooms, air ducts and outdoors. Various plastic device versions with different degrees of protection are available for the respective measuring task. A Pt100 temperature sensor in accordance with DIN EN 60751 Class B in a two-wire circuit is installed as standard, but variants with Pt500, Pt1000, Ni1000 and various NTC sensors are also possible. The connection terminals allow optional continuation in three- and four-wire circuits. An integrated measuring transducer can also be selected as an option.
Room, outdoor and duct resistance thermometers Typ: 902520/10-803-1003-1/333,(0..40°C) Measuring range from 0 to +40°C (measuring range only in conjunction with transmitter) Measuring insert 1x temperature sensor Pt100 in two-wire circuit Transmitter: 1x analog transmitter, output 0 to 10V (only in conjunction with 1x Pt100 t-w) (0-60°C) Protection class IP20 Suitabel for use in air conditioning technology Room, outdoor and duct resistance thermometers are designed for air conditioning technology and are mainly used for temperature measurement in rooms, air ducts and outdoors. Various plastic device versions with different degrees of protection are available for the respective measuring task. A Pt100 temperature sensor in accordance with DIN EN 60751 Class B in a two-wire circuit is installed as standard, but variants with Pt500, Pt1000, Ni1000 and various NTC sensors are also possible. The connection terminals allow optional continuation in three- and four-wire circuits. An integrated measuring transducer can also be selected as an option.
Screw-in resistance thermometer with connecting cable with fixed screw connectionType: 902050/10-380-1001-1-6-100-104-11-2500/316Silicone connecting cables Temperature range from -50 to +200 °C With fixed screw connection Single resistance thermometer 1x Pt 100 in three-wire circuit Tolerance class according to DIN EN 60 751: Class B (standard) Thermowell diameter: 6 mm Installation length 100 mm Process connection: G1/2 screw connection Connection cable end: Wire end ferrules to DIN 46 228 Part 4 (standard) Connection cable length: 2500 mm The screw-in resistance thermometer with connection cable is specially designed for use in various industries such as air conditioning and refrigeration technology, heating, furnace and apparatus engineering. It offers precise temperature measurement in both liquid and gaseous media. The installation design of this thermometer ensures reliable tightness, even under extreme conditions of negative and positive pressure. The possible applications range from dry to humid environments and, depending on the version, enable precise temperature measurement in the range from -50 to +400 °C. The connection cable of this screw-in resistance thermometer is available in various materials, including PVC, silicone, PTFE and metal braiding. This variety makes it possible to select the right variant for your application. The transition of the connecting cable is strain-relieved and an optional bend protection can be fitted to ensure the longevity of the connection. The measuring insert is equipped as standard with a Pt 100 temperature insert in accordance with DIN EN 60 751, class B in a two-wire circuit. Optionally, the measuring insert can also be selected with Pt 500 or Pt 1000. In addition, the connection can be made in either three- or four-wire circuits to meet individual requirements.
Screw-in resistance thermometer with connecting cable and loose screw connectionType: 902050/20-402-1003-1-6-37-114-11-2500/315,317Metal braided connection cablesTemperature range from -50 to +400 °CWith loose screw connectionSingle resistance thermometer1x Pt 100 in two-wire circuitTolerance class according to DIN EN 60 751: Class B (standard)Thermowell diameter: 6 mmInstallation length 37 mmProcess connection: M 10x1 screw connectionConnection cable end: Wire end ferrules to DIN 46 228 Part 4 (standard)Connection cable length: 2500 mmExtracode: Spring bend protection, connection cable shielded The screw-in resistance thermometer with connection cable is specially designed for use in various industries such as air conditioning and refrigeration technology, heating, furnace and apparatus engineering. It offers precise temperature measurement in both liquid and gaseous media. The installation design of this thermometer ensures reliable tightness, even under extreme conditions of negative and positive pressure. The possible applications range from dry to humid environments and, depending on the version, enable precise temperature measurement in the range from -50 to +400 °C. The connection cable of this screw-in resistance thermometer is available in various materials, including PVC, silicone, PTFE and metal braiding. This variety makes it possible to select the right variant for your application. The transition of the connecting cable is strain-relieved and an optional bend protection can be fitted to ensure the longevity of the connection. The measuring insert is equipped as standard with a Pt 100 temperature insert in accordance with DIN EN 60 751, class B in a two-wire circuit. Optionally, the measuring insert can also be selected with Pt 500 or Pt 1000. In addition, the connection can be made in either three- or four-wire circuits to meet individual requirements.
Screw-in resistance thermometer with connecting cable and loose screw connectionType: 902050/20-402-1001-1-6-37-114-11-2500/315,317Metal braided connection cablesTemperature range from -50 to +400 °CWith loose screw connectionSingle resistance thermometer1x Pt 100 in three-wire circuitTolerance class according to DIN EN 60 751: Class B (standard)Thermowell diameter: 6 mmInstallation length 37 mmProcess connection: M 10x1 screw connectionConnection cable end: Wire end ferrules to DIN 46 228 Part 4 (standard)Connection cable length: 2500 mmExtracode: Spring bend protection, connection cable shielded The screw-in resistance thermometer with connection cable is specially designed for use in various industries such as air conditioning and refrigeration technology, heating, furnace and apparatus engineering. It offers precise temperature measurement in both liquid and gaseous media. The installation design of this thermometer ensures reliable tightness, even under extreme conditions of negative and positive pressure. The possible applications range from dry to humid environments and, depending on the version, enable precise temperature measurement in the range from -50 to +400 °C. The connection cable of this screw-in resistance thermometer is available in various materials, including PVC, silicone, PTFE and metal braiding. This variety makes it possible to select the right variant for your application. The transition of the connecting cable is strain-relieved and an optional bend protection can be fitted to ensure the longevity of the connection. The measuring insert is equipped as standard with a Pt 100 temperature insert in accordance with DIN EN 60 751, class B in a two-wire circuit. Optionally, the measuring insert can also be selected with Pt 500 or Pt 1000. In addition, the connection can be made in either three- or four-wire circuits to meet individual requirements.
Screw-in resistance thermometer with connection cable and threaded protection tube Type: 902050/40-390-1003-1-8-25-111-11-2500/315,317 Metal braided connection cables Temperature range from -50 to +300 °C Single resistance thermometer 1x Pt 100 in two-wire circuit Tolerance class according to DIN EN 60 751: Class B (standard) Thermowell diameter: M 8 Insertion length 25 mm Process connection: M 8 screw connection Connection cable end: Wire end ferrules to DIN 46 228 Part 4 (standard) Connection cable length: 2500 mm Extra code: Spring bend protection, connection cable shielded The screw-in resistance thermometer with connection cable is specially designed for use in various industries such as air conditioning and refrigeration technology, heating, furnace and apparatus engineering. It offers precise temperature measurement in both liquid and gaseous media.The installation design of this thermometer ensures reliable tightness, even under extreme conditions of negative and positive pressure. The possible applications range from dry to humid environments and, depending on the version, enable precise temperature measurement in the range from -50 to +400 °C.The connection cable of this screw-in resistance thermometer is available in various materials, including PVC, silicone, PTFE and metal braiding. This variety makes it possible to select the right variant for your application. The transition of the connecting cable is strain-relieved and an optional bend protection can be fitted to ensure the longevity of the connection.The measuring insert is equipped as standard with a Pt 100 temperature insert in accordance with DIN EN 60 751, class B in a two-wire circuit. Optionally, the measuring insert can also be selected with Pt 500 or Pt 1000.In addition, the connection can be made in either three- or four-wire circuits to meet individual requirements.
Screw-in resistance thermometer with connection cable and threaded protection tube Type: 902050/40-390-1003-1-8-25-111-11-2500/315,317 Metal braided connection cables Temperature range from -50 to +300 °C Single resistance thermometer 1x Pt 100 in two-wire circuit Tolerance class according to DIN EN 60 751: Class B (standard) Thermowell diameter: M 8 Insertion length 25 mm Process connection: M 8 screw connection Connection cable end: Wire end ferrules to DIN 46 228 Part 4 (standard) Connection cable length: 2500 mm Extra code: Spring bend protection, connection cable shielded The screw-in resistance thermometer with connection cable is specially designed for use in various industries such as air conditioning and refrigeration technology, heating, furnace and apparatus engineering. It offers precise temperature measurement in both liquid and gaseous media.The installation design of this thermometer ensures reliable tightness, even under extreme conditions of negative and positive pressure. The possible applications range from dry to humid environments and, depending on the version, enable precise temperature measurement in the range from -50 to +400 °C.The connection cable of this screw-in resistance thermometer is available in various materials, including PVC, silicone, PTFE and metal braiding. This variety makes it possible to select the right variant for your application. The transition of the connecting cable is strain-relieved and an optional bend protection can be fitted to ensure the longevity of the connection.The measuring insert is equipped as standard with a Pt 100 temperature insert in accordance with DIN EN 60 751, class B in a two-wire circuit. Optionally, the measuring insert can also be selected with Pt 500 or Pt 1000.In addition, the connection can be made in either three- or four-wire circuits to meet individual requirements.
Screw-in resistance thermometer with connection head form J Type: 902030/31-380-1003-1-6-75-104/000 with stepped protection tube for air measurement Measuring range from -50 to +200 °C Single resistance thermometer 1x Pt 100 in two-wire circuit Tolerance class: Class B (standard) Thermowell diameter: 6 mm Installation length: 75 mm Process connection: G1/2 threaded connection Extra codes: none The screw-in RTD temperature probe with connection head is specially designed for use in various industries such as air conditioning and refrigeration technology and heating, furnace and apparatus engineering. It offers precise temperature measurement in both liquid and gaseous media, with a temperature range of -50 to +400 °C. The installation design of this thermometer ensures reliable tightness, even under extreme conditions of negative and positive pressure. The measuring insert is fitted as standard with a Pt100 temperature sensor in accordance with the DIN EN 60751:2009 / IEC 60751:2008 standards. This sensor has a temperature coefficient α of 3.850 × 10-3 °C-1 and is installed in a two-wire circuit. Versions with Pt500 or Pt1000 are also available as an option. For more precise measurement results, the connection can be made either in a three-wire or four-wire circuit, and it is also possible to integrate a transmitter into the connection head.
JUMO Dtrans T100 screw-in RTD temperature probe without transmitter, M12 x 1 machine plug connection Type: 902815/10-380-1011-1-6-100-104-24/000 Measuring range from -50 to + 200 °C 1x Pt100 in four-wire circuit Tolerance class: Class B (standard) Thermowell diameter: 6 mm Installation length: 100 mm Process connection: G1/2 screw connection Thermowell material: Stainless steel 316 L (material no. 1.4404/1.4435) EU and China RoHS compliant Extra code: without M12 x 1 push-on connector; protection class IP67 to DIN EN 60529 with attached machine plug USB interface for configuration with setup programme The screw-in resistance thermometer in a compact design consists of a thermowell with built-in temperature sensor, a process connection and a housing for the transmitter electronics. The programmable two-wire transmitter offers a robust solution for the precise recording of temperatures in a temperature measuring range of -50 to + 150°C, with a neck tube up to 260°C and is therefore versatile in use. The device has a USB interface that enables simple configuration via a setup programme. With the help of this programme, parameters such as measuring range, fine adjustment and measuring circuit monitoring can be adjusted to meet the requirements of different applications. The output signal 4 to 20 mA or reversed 20 to 4 mA is available linearised (temperature linear). The device is intended for industrial use and complies with European standards to ensure electromagnetic compatibility (EMC).